CDA TL1CH Handleiding

CDA Kraan TL1CH

Lees hieronder de 📖 handleiding in het Nederlandse voor CDA TL1CH (2 pagina's) in de categorie Kraan. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
For Service & Technical Support Call 01949 862012
TL1 - Lumina single lever
2 Year warranty:
In the unlikely event that you should experience any defect in the materials or workmanship of your new mixer within Two years of purchase,
the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the product that is defective. All
working parts and valves are guaranteed for a period of TWO years from purchase. Decorative surface finishes, electrical parts and O-rings
are guaranteed for ONE year from the date of ning care has been observed. This is provi purchase provided that our advice concer ded that
the mixer has been used for normal domestic purposes in the UK and that the care, installation and maintenance instructions have been
observed. The warranty extends to the original purchaser only. You should retain a copy of your dated invoice as proof of purchase to
validate any claims under this guarantee.
Care Instructions for your Kitchen Sink Mixer:
To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and
a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Any other cleaning action will
invalidate your warranty. If the tap has a diffuser it should be cleaned periodically.
Abrasive cleaners, scouring cleaners and acidic cleaners under any circumstances. Avoid contact with all solvents must not be used
(including chlorinated solvents, ketones or acetones as these may result in surface deterioration or etching). Also avoid contact with any
harsh household chemicals such as oven cleaners, drain cleaners, rust removers, paint strippers and toilet bowl cleaners, bar keepers friend
or Brasso.
Important Technical Data:
Minimum operating pressure 1.25 bar Maximum hot water temperature 70°C*
Maximum operating pressure 5.5 bar* Recommended hot water temperature 46°C
Power consumption 2.7W (max) DC inputs: 9V – 300mA (max)
Supplied transformer: linear, 200 V AC 50Hz 500 mA
*If these temperatures or pressures are exceeded, even for short periods, damage can result.
CDA taps are either WRAS approved or manufactured in accordance with recognised European standards. Please ensure that your
Kitchen mixer is fitted in accordance with Local Water Byelaws.
These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept
responsibility for problems that may occur through improper installation. Whilst assembling the tap take care not to accidentally loosen any
screwed assemblies.
Installation Preparation:
Before installing the new mixer it is essential that you thoroughly flush through the supply pipes in order to remove any remaining solder,
swarf or impurities from your system. Failure to carry out this simple procedure could cause problems or damage to the workings of the
mixertap.
We strongly recommend installing particle filter strainers and isolation valves to both the hot and cold feed pipes in an accessible position.
This will help to prevent premature failure of the valves and ease any future maintenance.
All parts should be removed from their packaging and inspected for any transport damage prior to installation.
Shut off your water heating system and ensure that your mains stopcock is closed. Open the lowest hot and cold taps in the house and
allow the water to run until the cold-water storage tank and pipes are fully empty. Please note, the hot water storage cylinder (if applicable)
will always remain full.
This mixertap requires a 35mm tap hole, if replacing an existing tap, remove the tap & clean the end of the feed pipes using wire wool the
tap hole area should be free from dirt and sealant.
Loosely position the tap and tail pipes to check if any alteration to the existing pipework is required, if this is the case do this now.
Installation:
1. Pass the upper seal (B) over all wires and pipes onto the base of the tap (A).
2. Pass the threaded section of the mixertap base (A), all wires and pipes through the taphole.
3. Pass the lower washer (E), metal washer (F), and white triangular stabiliser (G) (if fitting to a stainless steel sink) over
all wires, pipes and the threaded section of the mixertap base (A).
4. Pass the fixing nut (H) over all wires and pipes onto the threaded section base of the tap (A). With the tap correctly
located tighten the fixing nut fully.
5. Screw the hot flexible tail pipe (I) into the hot inlet pipe (C). note hot inlet pipe is tagged with [c].
6. Screw the cold flexible tail pipe (O) into the cold inlet pipe (D).
7. Connect the hot & cold flexible tail pipes (I&O) to the water supplies using ½” BSPx15mm compression fittings.
8. Screw the brass sensor (L) to the mixed water out flexible pipe (J), use the rubber washer (K) between the parts to
ensure a water tight seal.
9. Screw the mixed water in flexible pipe (N) to the brass temperature sensor (L) use the rubber washer (M) between the
parts to ensure a water tight seal.
10. Connect the input / output wires (BB,CC & DD) to the control box as shown, note the control box and wire tags are
colour coded in pairs. Important: Do not force the connectors incorrectly into the sockets and check the layout of the
connections now.
11. Plug the transformer into a mains outlet; IMPORTANT: ensure the transformer is set to 9V.
12. Connect the power lead to the control box (P), secure the control box using a cable tie or double sided foam tape.
Note: Above 45°C the tap will light fully red, below 20°C the tap will light fully blue, in between these temperatures the light
will be purple. The light will only activate at a flow rate above 1 litre / minute.
Key: Description: Qty
A Mixertap body 1
B Upper seal 1
C Hot water inlet pipe 1
D Cold water inlet pipe 1
E Lower washer 1
F Metal washer 1
G White triangular stabilizer
(use only if installing tap to
stainless steel sink) 1
H Fixing nut 1
I Hot flexible tail pipe 1
J Mixed water in flexible pipe 1
K Rubber washer 1
L Brass sensor 1
M Rubber washer 1
N Mixed water out flexible pipe 1
O Cold flexible tail pipe 1
Mains Transformer 1
BB black wire, yellow tag
CC Grey wire, red tag
DD Black wire, green tag
After installation:
Once you have visually checked the new fittings and
connections, ensure that all taps are closed except the
new mixer tap, which should be left open. Turn on the
water supply at the mains stop cock. As the system
starts to refill, check carefully for leaks. Once you are
fully satisfied that there are no leaks, turn on the water
heating.
Clean the tap to remove any marks created during
installation as instructed then replace the bag that has
been provided to protect the tap until it is ready for use.
C
DP
CB


Product specificaties

Merk: CDA
Categorie: Kraan
Model: TL1CH

Heb je hulp nodig?

Als je hulp nodig hebt met CDA TL1CH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Kraan CDA

Handleiding Kraan

Nieuwste handleidingen voor Kraan