The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. Rev. 11/11/19
S/B Printed in U.S.A.
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2019 by Bobrick Washroom Equipment, Inc.
Technical Data
L
L
Edge of
Flange to Wall
36''
915mm
4''
100mm
39-3/4''
1010mm
57-3/4''
1465mm
50''
1270mm
Edge of
Flange to Wall
Edge of
Flange to Wall
32''
815mm
4''
100mm
39-3/4''
1010mm
27-3/4''
705mm
24''
610mm
Edge of
Flange to Wall
continued . . .
42''
1065mm
4''
100mm
50''
1270mm
57-3/4''
1465mm
45-3/4''
1160mm
Edge of
Flange to Wall
Edge of
Flange to Wall
2''
50mm
2-1/4''
55mm
3-1/8''
80mm
5/16''
8mm
Snap Flange Cover
3-1/4''
85mm
Dia.
1-1/2''
38mm
End Mounting Flange
3-1/8''
80mm
Intermediate Flange
2-5/8''
65mm
2-1/4''
55mm
3-1/8''
80mm
1¼" (32mm) DIAMETER
STAINLESS STEEL GRAB BARS
WITH SNAP FLANGE
B-5806
SERIES
Satin-finish, slip-resistant surface.
Peened surface; add suffix .99 to model number
Specify Finish Required:
HORIZONTAL VERTICAL
B-5806 x 18, 24, 30, 36, 42, 48
TWO-WALL
TUB / SHOWER
COMPARTMENT BAR
B-5837
HORIZONTAL
TUB / SHOWER
COMPARTMENT BAR 24 x 36
B-58616
TWO-WALL
TOILET COMPARTMENT BAR 42 x 54
B-5897
The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. B-5806 r11/11/19
S/B Printed in U.S.A.
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2019 by Bobrick Washroom Equipment, Inc.
MATERIALS:
Grab Bar 18-8, Type-304, 18-gauge (1.2mm) stainless steel tubing with a satin-finish, slip-resistant surface. 1-1/4" (32mm) outside diameter. Ends are
heliarc welded to concealed mounting flanges. Clearance between the grab bar and wall is 1-1/2" (38mm).
Concealed Mounting Flanges 18-8, Type-304, 11-gauge (3.2mm) thick, stainless steel plate; end flanges 2" x 3-1/8" (50 x 80mm) with holes for
attachment to wall. Intermediate flanges 2-5/8" x 3-1/8" (65 x 80mm) wide x 3-1/8" (80mm) diameter.
Snap Flange Covers 18-8, Type-304, 22-gauge (0.8mm) drawn stainless steel with satin-finish. 3-1/4" (85mm) diameter x 5/8" (16mm) deep. Each cover
snaps over mounting flange to conceal mounting screws.
STRENGTH:
Bobrick grab bars that provide 1-1/2" (38mm) clearance from wall can support loads in excess of 900 pounds (408kg) if properly installed. Other grab bar
configurations can support loads in excess of 250 pounds (113kg) if properly installed, complying with accessible design (including ADAAG in the U.S.A.) for
structural strength.
Safety Warning: Grab bars are no stronger than the anchors and walls to which they are attached and, therefore, must be rmly
secured in order to support the loads for which they are intended. To avoid potential injury, the building owner or maintenance
personnel should remove the grab bar from service if the grab bar is not adequately secured to wall or if there is any observed
damage to the welds.
INSTALLATION:
Provide concealed anchor device or backing as specified or required in accordance with local building codes before wall is finished. Fasten concealed mounting
flanges to anchor device or backing with at least two screws opposing each other in each flange. Snap ange covers over each mounting flange to conceal
mounting screws. Concealed anchor devices and mounting screws are not included with Bobrick grab bars and must be specified as an accessory.
For Grab Bars with an Intermediate Flange(s), Pull Snap-Flange Covers away from mounting flanges. Place grab bar in desired mounting location. Use
intermediate flange as a template to mark location of mounting screws at intermediate flange only. Mark screw locations at the center of the slot in the middle
of the double-keyhole shaped mounting holes (2) in the intermediate flange. Remove grab bar from wall. Drive the intermediate flange mounting screws into
wall at marked locations. Make sure to leave a space of just over 1/8'' (3.17mm) between the underside of the screw head and the wall. Install grab Note:
bar on the wall by placing the round ends of the intermediate flange double-keyhole shaped mounting holes over the mounting screws (2) are located in the
middle of the flange slots. Install the mounting screws into the wall at the endanges and secure tightly. Tighten the mounting screws at the intermediate
ange. Press all snap-flange covers into place to conceal mounting flanges.
Note: Recommend use of 1/4'' or #14 sheet metal or wood screws to install Intermediate Flange. #12 screws may also be used.
Important Notes:
1. Bobrick offers a mounting kit for installing grab bars; Mounting Kits one Bobrick mounting kit is required for each flange.
2. Bobrick offers a grab bar fastening system that secures all Bobrick grab bar series; Grab Bar Fastener one Bobrick fastener is required for
each flange. Install grab bar without backing in wall requires minimum 5/8" (16mm) thick painted or tiled drywall.
3. Optional Anchor Device Bobrick grab bar anchor device includes stainless steel machine screws to be used for attaching grab bars to anchors.
one Bobrick concealed anchor device is required for each flange.
SPECIFICATION:
Grab bar shall be Type-304 stainless steel with a satin-finish, slip-resistant surface. Grab bar shall have 18-gauge (1.2mm) wall thickness and 1-1/4" (32mm) outside
diameter. Clearance between the grab bar and wall shall be 1-1/2" (38mm). Concealed mounting flanges shall be 11-gauge (3.2 mm) thick stainless steel plate,
2" x 3-1/8" (50 x 80mm), and equipped with at least two screw holes for attachment to wall. Flange covers shall be 22-gauge (0.8mm) stainless steel, 3-1/4"
(85mm) diameter, and shall snap over mounting flanges to conceal mounting screws and/or WingIt fasteners. Ends of grab bar shall pass through concealed
mounting flanges and be heliarc welded to form one structural unit. Grab bar shall comply with accessible design (including ADAAG in the U.S.A.) for
structural strength.
Grab Bar shall be Model __________ (insert model number) of Bobrick Washroom Equipment, Inc., Clifton Park, New York; Jackson,
Tennessee; and Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario; Bobrick Washroom Equipment Pty.
Ltd., Australia; and Bobrick Washroom Equipment Limited, United Kingdom.
Description
Consists of 10–32 x 5/16'' round-head, Phillips 18/8 stainless steel screws.
(1) WingIt grab bar fastener.
WingIt™ Fastener No.
251-4
Mounting Kit No.
252-30
Description
Consists of (3) #14 x 2½'' Type-304 stainless steel,
Phillips round-head, sheet-metal screws.
Description
Anchor for 3/4" to 1" (19-25mm) panel
1 anchor required for each flange.
Anchor for 1/2" to 1" (13mm) panel
1 anchor required for each flange.
Optional Anchor No.
2583
2586


Product specificaties

Merk: Bobrick
Categorie: Niet gecategoriseerd
Model: B-5806

Heb je hulp nodig?

Als je hulp nodig hebt met Bobrick B-5806 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Bobrick

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd