Installation Manual
Type:
:
:
::Enclosed Type Switching Power Supply
(Families: G3, NE, LRS, SE, PFC, HSP, SPV, USP, RST, G5, MSP)
Introduction
Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be
installed inside the case of the end system. Mean Well’s enclosed type power supplies include 2 different groups of
power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept.
Installation
( )1 Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it can’t be re-connected inadvertently!
( )2 Keep enough insulation distance between mounting screws and internal components of power supplies. Please
refer to case drawing on specifications to receive the maximum length of mounting screw.
( )3 Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a de-rating in output current. Please refer to
the specification sheets to receive the optimum mounting position and information about the de-rating curve.
( )4 Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept
when the adjacent device is a heat source.
( )5 Input and Output terminal
Terminal Screw
Series Screw Size Suggested
Torque
RSP-750 / 1000 / 1500 / 2000 / 2400 / 3000
SE-450 / 1000 / 1500
HEP-600 MSP-300 ,HRP-300,HRPG-300,
SP-480,SP-750,SPV-1500,USP-500,RST-10000
M4 10-12kgf-cm
HRP-075 / 100 / 150 / 200,HRPG-150 / 200
LRS-035 / 050 / 075 / 100 / 150 / 150F / 200 / 350
MSP-100 / 200
NED-035 / 050 / 075 / 100,NET-035 / 050 / 075
NES-025 / 035 / 050 / 075 / 100 / 150 / 200 / 350
QP-200 / 320 / 375
RD-050 / 065 / 085 / 125,RID-050 / 065 / 085 / 125
RS-035 / 050 / 075 / 100 / 150
RSP-075 / 100 / 150 / 200 / 320
SP-075 / 100 / 150 / 200 / 240 / 320,SPV-150/300
SE-100 / 200 / 350,HSP-250,PSP-600
M3.5 8-10 kgf-cm
RSP-1600
RD-035,RT-050 / 065 / 085 / 125
RQ-050 / 065 / 085 / 125
TP-075 / 100 / 150,QP-100 / 150
RS-015 / 025
NES-015,USP-150
M3 6-8 kgf-cm
ERP-350
HDP-190 / 240
NEL-200 / 300
#6 8-10 kgf-cm
Installation Manual
Terminal Screw
Series
Input Output
Screw Size Suggested
Torque Screw Size Suggested
Torque
HRP-450 / 600
HRPG-450 / 600
MSP-450 / 600
SE-600
M3 6-8kgf-cm M4 10-12kgf-cm
HSP-150 / 200 /300
HSN-200 / 300 M3 6-8kgf-cm M3.5 8-10kgf-cm
RSP-500 M3.5 8-10kgf-cm M4 10-12kgf-cm
RST-5000 M4 10-12kgf-cm 10-12kgf-cm M8
NEL-400 #6 8-10kgf-cm M3 8-10kgf-cm
( )6 Recommended wires are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Cross-section of
Lead(mm2 ) 0.75 1.00 1.5 2.5 4 6
Note: Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact.
( )7 For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
( )1 Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
( )2 Please do not install power supplies in places with high moisture or near the water.
( )3 Please do not install power supplies in places with high ambient temperature or near fire source. The
maximum ambient temperature please refer to their specifications.
( )4 Output current and output wattage must not exceed the rated values on specifications.
( )5 The ground(FG) must be connected to earth ground.
( )6 All MW’s PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure,
when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
Installation Manual
Manufacturer:
:
:
::
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office:
:
:
::
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu
Product specificaties
Merk: | BIG |
Categorie: | Autoracebaan |
Model: | Waterplay Amsterdam |
Kleur van het product: | Blue, Yellow |
Gewicht: | 6200 g |
Breedte: | 1430 mm |
Diepte: | 1750 mm |
Hoogte: | 270 mm |
Aanbevolen leeftijd (max): | 7 jaar |
Aanbevolen leeftijd (min): | 3 jaar |
Type verpakking: | Doos |
Land van herkomst: | Duitsland |
Materiaal: | Kunststof |
Voorgesteld geslacht: | Jongen/meisje |
Type product: | Voertuig & circuitset |
Heb je hulp nodig?
Als je hulp nodig hebt met BIG Waterplay Amsterdam stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Autoracebaan BIG
6 Juni 2023
5 Juni 2023
4 Juni 2023
1 Juni 2023
21 Mei 2023
16 Mei 2023
Handleiding Autoracebaan
- Autoracebaan VTech
- Autoracebaan Fisher Price
- Autoracebaan Mattel
- Autoracebaan Carrera
- Autoracebaan Step2
Nieuwste handleidingen voor Autoracebaan
11 December 2024
28 Juni 2023
11 Juni 2023
22 Mei 2023
5 Mei 2023
29 April 2023
21 April 2023
15 April 2023
29 Maart 2023