Audix OM2 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Audix OM2 (2 pagina's) in de categorie Microfoon. Deze handleiding was nuttig voor 69 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
OM2
OVERVIEW:
Designed, assembled and tested by Audix in the USA, the OM2 is a
dynamic vocal microphone used for a wide variety of live and studio
applications. The OM2 is known for its clear and accurate sound
reproduction, resistance to feedback and ability to handle very high
sound pressure levels without distortion.
The OM2 is characterized with a tight and uniformly controlled
hypercardioid polar pattern which helps to isolate the vocals from
the rest of the instruments on stage. With a wide frequency range
of 50 Hz - 16 kHz, the OM2 employs a VLM™ (Very Low Mass)
diaphragm for natural sound with exceptional transient response.
The OM2 is designed with slight bass proximity and a tailored
mid-range, giving it a full bodied sound on small to mid-size PA
systems. The OM2 is well balanced, comfortable to hold, durable
and manufactured with high standards and tight tolerances.
Roadworthy construction includes a precision die cast zinc alloy
body, black e-coat nish, laser etched model and serial number,
steel mesh grill, SwitchcraftÂŽ XLR connector and heavy duty nylon
clip.
FEATURES:
Clear, accurate sound reproduction
Handles high SPL without distortion
Low handling noise
Provides exceptional gain before feedback
Provides excellent vocal isolation on stage
Dent resistant steel spring grill
5 year warranty
APPLICATIONS:
Lead or backing vocals
Live recording
Broadcast
Home studio - vocal and instrument
Sax, brass, guitar, dobro, flute, percussion, drums
SUPPLIED ACCESSORIES:
Heavy duty nylon mic clip (MC1)
Carrying pouch (P1)
OPTIONAL ACCESSORIES:
WS357 - External foam windscreen
CBL-20 - 20’ XLR-XLR low noise mic cable
T50K - Low to high impedance matching transformer
MODEL VARIATIONS:
OM2-S - Same as above with On-Off switch
DYNAMIC VOCAL MICROPHONE
OM2
Dynamic Vocal
MC1 WS357 CBL-20 T50K
Transducer Type Dynamic
Frequency Response 50 Hz - 16 kHz
Polar Pattern Hypercardioid
Output Impedance 250 ohms
Sensitivity 1.7 mV / Pa @ 1k
Capsule Technology VLM Type B
Off Axis Rejection > 25 dB
Maximum SPL ≥140 dB
Power Requirements None
Connector SwitchcraftÂŽ male
XLR connector
Polarity Positive pressure on diaphragm
produces positive voltage on pin 2
relative to pin 3 of output
XLR connector
Housing / Finish Zinc Alloy /
Black E-coat
Weight 307 g / 10.8 ounces
Length 176 mm / 6.9 inches
SPECIFICATIONS: ARCHITECTS AND ENGINEERS SPECIFICATIONS:
The microphone shall be of the dynamic type and the polar pattern of the microphone
shall be hypercardioid. The nominal output impedance shall be equal to 250 ohms at
1 kHz. The microphone shall have a sensitivity of 1.7 mV / Pa at 1 kHz and a sound
pressure level ≥140 dB. The microphone body shall be of zinc alloy and the grill cap
shall be steel wire mesh. The overall dimensions shall be 23 mm in diameter at the
base, 53 mm in diameter at the widest point on the grill and 176 mm in length. The
microphone shall be the Audix OM2.
OPERATION:
The OM2 is a low impedance microphone and should be plugged into the “mic level”
input of your console, mixer, or recording device. Please note that your microphone
does not require phantom power and will not be effected in any way by phantom
power should it be running simultaneously while the microphone is in operation. Avoid
plugging or unplugging the microphone from the PA system unless the channel is
muted or the volume of the system turned down. Failure to do so may result in a loud
“popping” noise which could seriously damage the speakers in the PA system.
USER TIPS:
The OM2 has a very tight pick-up pattern in order to help eliminate sound from
other instruments on stage from “bleeding” into the microphone. For best results, it
is important to sing directly into the mic at close proximity (within 2 inches). When
using oor monitors, position the microphone so that it is parallel to the oor. When
using multiple microphones on a live performance stage, allow a distance of 2-3 feet
between mics to avoid phase issues.
*Further miking techniques may be found on our website at www.audixusa.com
www.audixusa.com Call: 503-682-6933 Fax: 503-682-7114
Audix Corporation 9400 SW Barber Street, Wilsonville, OR 97070
SERVICE AND WARRANTY:
This microphone is under warranty for
a period of 5 years from any and all
manufacturing defects. Should your
microphone fail in any way, please con-
tact the Audix Service department at
503-682-6933. A Return Authorization
number is required before returning
any products.
CARE AND MAINTENANCE:
The OM2 is manufactured to exacting specs
with roadworthy construction. However, the
capsule is highly sensitive and should be
handled with care. Avoid extreme temperatures
and be sure to store your microphone in the
pouch provided when not in use. Moisture of
any kind can adversely affect the sound and
performance of your microphone.
FREQUENCY / POLARS:
To register your
microphone, please visit
www.audixusa.com
***All specications subject to change without notice.
DIMENSIONS (mm):
OM2


Product specificaties

Merk: Audix
Categorie: Microfoon
Model: OM2
Kleur van het product: Zwart
Diepte: 176 mm
Hoogte: 53 mm
Soort: Microfoon voor podiumpresentaties
Connectiviteitstechnologie: Bedraad
Ruisonderdrukking: Ja
Impedantie: 290 Ohm
Aansluiting: XLR-3
Compatibele producten: MC1\r\nWS357\r\nCBL20\t\t\r\nT50K
Microphone direction type: CardioĂŻde
Frequentie microfoon: 50 - 16000 Hz
XLR out: Ja
Diepte (imperiaal): 6.9 "
Aantal producten inbegrepen: 1 stuk(s)
Gewicht microfoon: 307 g
Output impedance: 290 Ohm
Afmetingen microfoon (DxH): 176 x 53 mm

Heb je hulp nodig?

Als je hulp nodig hebt met Audix OM2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Microfoon Audix

Handleiding Microfoon

Nieuwste handleidingen voor Microfoon