AP-100 Series Wireless Access Point
Installation Guide
About the Aruba AP-100 Series Access Points
The Aruba AP-104 and AP-105 wireless access points support the IEEE 802.11n
standard for high-performance WLAN. This access point uses MIMO (Multiple-in,
Multiple-out) technology and other high-throughput mode techniques to deliver
high-performance, 802.11n 2.4 GHz and 5 GHz functionality while simultaneously
supporting existing 802.11a/b/g wireless services. The AP-100 Series access point
works only in conjunction with an Aruba Controller.
The Aruba AP-100 Series access point provides the following capabilities:
Wireless transceiver
Protocol-independent networking functionality
IEEE 802.11a/b/g/n operation as a wireless access point
IEEE 802.11a/b/g/n operation as a wireless air monitor
Compatibility with IEEE 802.3af PoE
Central management configuration and upgrades through an Aruba
Controller
Package Contents
AP-104 or AP-105 access point
Installation guide (this document)
AP-100 Series Hardware Overview
Figure 1 AP-100 Front (AP-104 shown)
LEDs
The AP-100 Series is equipped with four LEDs that indicate the status of the
various components of the AP.
PWR: Indicates whether or not the AP-100 Series is powered-on
ENET: Indicates the status of the AP-100 Series’s Ethernet port
11A/N: Indicates the status of the 802.11a/n radio
11B/G/N: Indicates the status of the 802.11b/g/n radio
For information about the AP-100 Series’s LED behavior, see .Table 1 on page 2
External Antenna Connectors
The AP-104 is designed for use with external antennas and equipped with four
external, female RP-SMA antenna connectors. Antenna connector mapping:
R0/A0: Radio 0 (5GHz), chain 0
R0/A1: Radio 0 (5GHz), chain 1
R1/A0: Radio 1 (2.4GHz), chain 0
R1/A1: Radio 1 (2.4GHz), chain 1
The AP-105 is equipped with internal antennas.
Figure 2 AP-100 Series Rear
Console Port
Use the console port to connect to a terminal for direct local management.
Ethernet Port
AP-100 Series is equipped with a single 10/100/1000Base-T (RJ-45) auto-sensing,
MDI/MDX wired-network connectivity port. This port supports IEEE 802.3af
Power over Ethernet (PoE) compliance, accepting 48VDC as a standard defined
Powered Device (PD) from a Power Sourcing Equipment (PSE) such as a PoE
midspan injector, or network infrastructure that supports PoE.
DC Power Socket
If PoE is not available, an optional Aruba AP AC-DC adapter kit (sold separately)
can be used to power the AP-100 Series.
Reset Button
The reset button can be used to return the AP to factory default settings. To reset
the AP:
1. Power off the AP.
2. Press and hold the reset button using a small, narrow object, such as a
paperclip.
3. Power-on the AP without releasing the reset button. The power LED will
flash within 5 seconds.
4. Release the reset button.
The power LED will flash again within 15 seconds indicating that the reset is
completed. The AP will now continue to boot with the factory default settings.
Before You Begin
Pre-Installation Network Requirements
After WLAN planning is complete and the appropriate products and their
placement have been determined, the Aruba controller(s) must be installed and
initial setup performed before the Aruba APs are deployed.
For initial setup of the controller, refer to the for ArubaOS Quick Start Guide
the software version installed on your controller.
AP Pre-Installation Checklist
Before installing your AP-100 Series AP, ensure that you have the following:
CAT5 UTP cable of required length
One of the following power sources:
IEEE 802.3af-compliant Power over Ethernet (PoE) source
Supports full functionality for AP-100 Series
The POE source can be any power source equipment (PSE) controller or
midspan PSE device
Aruba AP AC-DC adapter kit (sold separately)
Aruba Controller provisioned on the network:
Layer 2/3 network connectivity to your access point
One of the following network services:
Aruba Discovery Protocol (ADP)
DNS server with an “A” record
DHCP Server with vendor-specific options
Summary of the Setup Process
Successful setup of an AP-100 Series access point consists of five tasks, which
must be performed in this order:
1. Verify pre-installation connectivity.
2. Identify the specific installation location for each AP.
3. Install each AP.
4. Verify post-installation connectivity.
5. Configure each AP.
Verifying Pre-Installation Connectivity
Before you install APs in a network environment, make sure that the APs are
able to locate and connect to the controller after power on.
Specifically, you must verify the following conditions:
When connected to the network, each AP is assigned a valid IP address
APs are able to locate the controller
Refer to the Guide for instructions on locating and ArubaOS Quick Start
connecting to the controller.
Identifying Specific Installation Locations
You can mount the AP-100 Series access point on a wall or on the ceiling. Use the
AP placement map generated by Aruba’s RF Plan software application to
determine the proper installation location(s). Each location should be as close
as possible to the center of the intended coverage area and should be free from
obstructions or obvious sources of interference. These RF absorbers/reflectors/
interference sources will impact RF propagation and should have been
accounted for during the planning phase and adjusted for in RF plan.
Identifying Known RF Absorbers/Reflectors/Interference
Sources
Identifying known RF absorbers, reflectors, and interference sources while in
the field during the installation phase is critical. Make sure that these sources are
taken into consideration when you attach an AP to its fixed location.
RF absorbers include:
Cement/concrete—Old concrete has high levels of water dissipation, which
dries out the concrete, allowing for potential RF propagation. New concrete
has high levels of water concentration within the concrete, blocking RF
signals.
Natural Items—Fish tanks, water fountains, ponds, and trees
Brick
RF reflectors include:
Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/
heating ducts, mesh windows, blinds, chain link fences (depending on
aperture size), refrigerators, racks, shelves, and filing cabinets
Do not place an AP between two air conditioning/heating ducts. Make sure
that APs are placed below ducts to avoid RF disturbances.
RF interference sources include:
Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
Cordless headset such as those used in call centers or lunch rooms
Installing the AP
Using the Integrated Wall-Mounting Slots
The keyhole-shaped slots on the back of the AP can be used to attach the device
upright to an indoor wall or shelf. When you choose the mounting location, allow
additional space at the right of the unit for cables.
1. Since the ports are on the back of the device, make sure that you mount the
AP is such a way that there is a clear path to the Ethernet port, such as a pre-
drilled hole in the mounting surface.
2. At the mounting location, install two screw on the wall or shelf, 1 7/8 inches
(4.7 cm) apart. If you are attaching the device to drywall, Aruba recommends
using appropriate wall anchors (not included).
3. Align the mounting slots on the rear of the AP over the screws and slide the
unit into place (see ).Figure 3
Figure 3 Installing the AP-100 Series Access Point on a Wall
Using the Integrated Ceiling Tile Rail Slots
The snap-in tile rail slots on the rear of the AP can be used to securely attach the
device directly to a 15/16" wide, standard ceiling tile rail.
1. Pull the necessary cables through a prepared hole in the ceiling tile near
where the AP will be placed.
2. If necessary, connect the console cable to the console port on the back of the
AP.
Hold the AP next to the ceiling tile rail with the ceiling tile rail mounting slots at
approximately a 30-degree angle to the ceiling tile rail (see ). Make sure Figure 4
that any cable slack is above the ceiling tile.
Figure 4 Orienting the Ceiling Tile Rail Mounting Slots
3. Pushing toward the ceiling tile, rotate the AP clockwise until the device
clicks into place on the ceiling tile rail.
Inform your supplier if there are any incorrect, missing, or damaged parts. If
possible, retain the carton, including the original packing materials. Use
these materials to repack and return the unit to the supplier if needed.
PWR
ENET
11B/G/N
11A/N
External
Antenna
Connector
!
!
!
!!
FCC Statement: Improper termination of access points installed in the
United States configured to non-US model controllers will be in violation of
the FCC grant of equipment authorization. Any such willful or intentional
violation may result in a requirement by the FCC for immediate termination
of operation and may be subject to forfeiture (47 CFR 1.80).
!
!
!
!!
EU Statement:
Lower power radio LAN product operating in 2.4 GHz and 5 GHz bands.
Please refer to the for details on restrictions.ArubaOS User Guide
Produit réseau local radio basse puissance operant dans la bande
fréquence 2.4 GHz et 5 GHz. Merci de vous referrer au ArubaOS User
Guide pour les details des restrictions.
Low Power FunkLAN Produkt, das im 2.4 GHz und im 5 GHz Band arbeitet.
Weitere Informationen bezlüglich Einschränkungen finden Sie im ArubaOS
User Guide.
Apparati Radio LAN a bassa Potenza, operanti a 2.4 GHz e 5 GHz. Fare
riferimento alla ArubaOS User Guide per avere informazioni detagliate sulle
restrizioni.
AP105_002
CONSOLE
ENET
12V 1.25A
48V 350mA
CONSOLE
ENET
Power
Connector
Reset Button
Aruba Networks, Inc., in compliance with governmental requirements, has
designed the AP-100 Series access points so that only authorized network
administrators can change the settings. For more information about AP
configuration, refer to the ArubaOS Quick Start Guide and ArubaOS User
Guide.
!
!
!
!!
Access points are radio transmission devices and as such are subject to
governmental regulation. Network administrators responsible for the
configuration and operation of access points must comply with local
broadcast regulations. Specifically, access points must use channel
assignments appropriate to the location in which the access point will be
used.
Service to all Aruba Networks products should be performed by trained
service personnel only.
!
!
!
!!
Make sure the AP fits securely on the ceiling tile rail when hanging the
device from the ceiling; poor installation could cause it to fall onto people
or equipment.
AP105_003
A
P105_004
AP-100 Series Wireless
Access Point
Installation Guide
www.arubanetworks.com
1344 Crossman Avenue
Sunnyvale, California 94089
Phone: 408.227.4500
Fax 408.227.4550
AP-100 Series Wireless Access Point | Installation Guide
Part Number 0511027-02 | April 2012
Contacting Aruba Networks
Table 1
Web Site Support
Main Site http://www.arubanetworks.com
Support Site https://support.arubanetworks.com
Software Licensing Site https://licensing.arubanetworks.com/login.php
Wireless Security Incident
Response Team (WSIRT)
http://www.arubanetworks.com/support/wsirt.php
Americas and APAC Support Email support@arubanetworks.com
EMEA Support Email emea.support@arubanetworks.com
WSIRT Email
Please email details of any security
problem found in an Aruba product.
wsirt@arubanetworks.com
Table 2
Telephone Support
Aruba Corporate +1 (408) 227-4500
FAX +1 (408) 227-4550
Copyright
© 2010 Aruba Networks, Inc. AirWave®, Aruba Networks®, Aruba Mobility Management System®, Bluescanner,
For Wireless That Works®, Mobile Edge Architecture, People Move. Networks Must Follow., RFProtect
®, The All
Wireless Workplace Is Now Open For Business, and The Mobile Edge Company® are trademarks of Aruba
Networks, Inc. All rights reserved. All other trademarks are the property of their respective owners.
Open Source Code
Certain Aruba products include Open Source software code developed by third parties, including software code
subject to the GNU General Public License ("GPL"), GNU Lesser General Public License ("LGPL"), or other Open
Source Licenses. The Open Source code used can be found at this site:
http://www.arubanetworks.com/open_source
Legal Notice
The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate
other vendors' VPN client devices constitutes complete acceptance of liability by that individual or corporation for
this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against
it with respect to infringement of copyright on behalf of those vendors.
Warranty
This hardware product is protected by the standard Aruba warranty of one year parts/labor. For more information,
refer to the ARUBACARE SERVICE AND SUPPORT TERMS AND CONDITIONS.
Altering this device (such as painting it) voids the warranty.
Connecting Required Cables
Install cables in accordance with all applicable local and national regulations and
practices.
Ethernet Ports
The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/
MDX connections. Use these ports to connect the AP to a twisted pair Ethernet
LAN segment or directly to an Aruba Controller. Use a 4- or 8-conductor,
Category 5 UTP cable up to 100 m (325 feet) long.
The 10/100/1000 Mbps Ethernet port is on the back of the AP. The port has an RJ-
45 female connector with the pin-outs shown in .Figure 5
Figure 5 Gigabit Ethernet Port Pin-Out
Serial Console Port
The serial console port (Console) allows you to connect the AP to a serial
terminal or a laptop for direct local management. This port is an RJ-45 female
connector with the pinouts described in . Connect this port in one of the Figure 6
following ways:
Connect it directly to a terminal or terminal server using an Ethernet cable.
Use a modular adapter to convert the RJ-45 (female) connector on the AP to a
DB-9 (male) connector, and connect the adapter to a laptop using an RS-232
cable. See for connector details of the adapter.Figure 7
Figure 6 Serial Port Pin-Out
Figure 7 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion
Power Connection
The AP-100 Series has a single 12V DC power jack socket to support powering
through an AC-to-DC power adapter.
Verifying Post-Installation Connectivity
The integrated LEDs on the AP can be used to verify that the AP is receiving
power and initializing successfully (see ). Refer to the Table 1 ArubaOS Quick
Start Guide for further details on verifying post-installation network
connectivity.
Configuring the AP-100 Series
AP Provisioning/Reprovisioning
Provisioning parameters are unique to each AP. These local AP parameters are
initially configured on the controller which are then pushed out to the AP and
stored on the AP itself. Aruba recommends that provisioning settings be
configured via the ArubaOS Web UI only. Refer to the for ArubaOS User Guide
complete details.
AP Configuration
Configuration parameters are network or controller specific and are configured
and stored on the controller. Network configuration settings are pushed out to
the AP(s) but remain stored on the controller.
Configuration settings can be configured via the ArubaOS Web UI, ArubaOS CLI,
or Aruba MMS. Refer to their respective guides for further details: the ArubaOS
User Guide Aruba Mobility Management System User Guide or .
Product Specifications
Electrical
Ethernet:
1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces
MDI/MDX
IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T). IEEE 802.3ab
(1000Base-T)
Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA (see Figure
5 for pin configuration)
Power:
12 VDC power interface, supports powering through an AC-to-DC power
adapter
For additional specifications on this product, please refer to the data sheet. The
data sheet can be found at .www.arubanetworks.com
Proper Disposal of Aruba Equipment
For the most current information about Global Environmental Compliance and
Aruba products, see our website at .www.arubanetworks.com
Waste of Electrical and Electronic Equipment
Aruba products at end of life are subject to separate collection
and treatment in the EU Member States, Norway, and
Switzerland and therefore are marked with the symbol shown
at the left (crossed-out wheelie bin). The treatment applied at
end of life of these products in these countries shall comply
with the applicable national laws of countries implementing
Directive 2002/96EC on Waste of Electrical and Electronic
Equipment (WEEE).
European Union RoHS
Aruba products also comply with the EU Restriction of
Hazardous Substances Directive 2002/95/EC (RoHS). EU
RoHS restricts the use of specific hazardous materials in
the manufacture of electrical and electronic equipment.
Specifically, restricted materials under the RoHS Directive are Lead (including
Solder used in printed circuit assemblies), Cadmium, Mercury, Hexavalent
Chromium, and Bromine. Some Aruba products are subject to the exemptions
listed in RoHS Directive Annex 7 (Lead in solder used in printed circuit
assemblies). Products and packaging will be marked with the “RoHS” label
shown at the left indicating conformance to this Directive.
China RoHS
Aruba products also comply with China environmental declaration
requirements and are labeled with the “EFUP 10” label shown at
the left.
Safety and Regulatory Compliance
Aruba Networks provides a multi-language document that contains country-specific
restrictions and additional safety and regulatory information for all Aruba access points.
This document can be viewed or downloaded from the following location:
www.arubanetworks.com/safety_addendum
The device is electronically labeled and the FCC ID will be displayed via the controller
WebUI under the About menu.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
EMC Compliance and Warning Statement
IEC 60601-1-2: 2007
EN 60601-1-2: 2007
The AP-105 has been tested and found to comply with the limits of the standard for
medical devices, IEC 60601-1-2:2007. The unit also complies with the requirements of EN
60601-1-2:2007, providing the presumption of compliance to the European Union’s Medical
Device Directive 2007/47/EC. The limits are designed to provide reasonable protection
against harmful interference in a typical medical installation. This equipment generates,
uses and can radiate radio frequency energy, and, if not installed and used in accordance
with the manufacturer’s instructions may cause harmful interference to other devices in
the vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment causes interference with other devices, which may be
determined by turning the equipment off and on, the user is encouraged to try and correct
the interference by one or more of the following measures:
Reorient or relocate the device receiving the interference.
Increase the separation between the equipment.
Connect the equipment into an outlet on a circuit different from that to which the
other device(s) are connected.
Consult the manufacturer or field service technician for help.
The Model AP-105 do not have an Applied Part as defined in IEC 60601-1. The protection
against electric shock is Class ll.
Device is not protected against ingress of liquids and has a protection class of IPX0 as
defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the presence of
flammable mixtures.
The unit is considered “Continuous Operation” equipment as defined by IEC 60601-1.
Power Consumption – 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for external
AC supplied power (adapter sold separately); Maximum power consumption – 12.5W.
Mechanical Dimensions: 132mm x 135mm x 45mm; 300g.
Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5 to 95%
non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F).
If both POE and DC power are available, the AP uses POE even when there
is not enough POE voltage available to power the AP.
Table 1 AP-100 Series Series LED Meanings
LED Color/State Meaning
PWR Off No power to AP
Green flashing System initializing
Red steady System failed to
initialize, contact TAC
Green steady Power on, device ready
ENET
(10/100/1000 Mbps)
Off No link
Green on 1000 Mbps link
Amber on 10/100 Mbps link
Green flashing Ethernet link activity
1000Base-T Gigabit
Ethernet Port
RJ-45 Female
Pin-Out
Signal Name
1
2
3
4
5
6
7
8
BI_DC+
BI_DC-
BI_DD+
BI_DD-
BI_DA+
BI_DA-
BI_DB+
BI_DB-
Function
Bi-directional pair +C
Bi-directional pair -C
Bi-directional pair +D
Bi-directional pair -D
Bi-directional pair +A
Bi-directional pair -A
Bi-directional pair +B
Bi-directional pair -B
Serial
Console Port
1
2
3
4
5
6
7
8
TxD
GND
RxD
RJ-45 Female
Pin-Out
Direction
Input
Output
GND
3
4
5
2
5
6 3
RJ-45 DB-9
Internal
Connections
TxD
GND
RxD
1
2
3
4
5
6
7
8
TxD
GND
RxD
RJ-45 Female
Pin-Out
Direction
Input
Output
DB-9 Male
Pin-Out
TxD
RxD
Ground
5
4
3
2
1
9
8
7
6
Direction
Input
Output
11A/N Off 5 GHz radio is disabled
Amber 5 GHz radio enabled in
WLAN mode
Green 5 GHz radio enabled in
11n mode
Green flashing 5 GHz Air Monitor or RF
Protect mode
11B/G/N Off 2.4 GHz radio disabled
Amber 2.4 GHz radio enabled in
WLAN mode
Green 2.4 GHz radio enabled in
11n mode
Green flashing 2.4 GHz Air Monitor or
RF Protect mode
If a power adapter other than the one provided by Aruba Networks is used
in the US or Canada, it should be cULus (NRTL) Listed, with an output
rated 12 VDC, minimum 1.25A, marked “LPS” or “Class 2,” and suitable for
plugging into a standard power receptacle in the US and Canada.
Table 1 AP-100 Series Series LED Meanings
LED Color/State Meaning
!
!
!
!!
RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure
limits. This equipment should be installed and operated with a minimum distance of 7.9 inches
(20 cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter
must not be co-located or operating in conjunction with any other antenna or transmitter. When
operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to
reduce the potential for harmful interference with co-channel Mobile Satellite Systems.
᳝↦᳝ᆇ⠽䋼ໄᯢ
᳝↦᳝ᆇ⠽䋼ໄᯢ
᳝↦᳝ᆇ⠽䋼ໄᯢ
᳝↦᳝ᆇ⠽䋼ໄᯢ᳝↦᳝ᆇ⠽䋼ໄᯢ
Hazardous Materials Declaration
᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance)
䚼ӊৡ⿄
(Parts) 䪙
3E
∲
+J
䬝
&G
݁Ӌ䫀
&U

໮⒈㘨㣃
3%%
໮⒈Ѡ㣃䝮
3%'(
⬉䏃ᵓ
(
PCA Boards)
h ƻ ƻ ƻ ƻ ƻ
ᴎẄ㒘ӊ
(Mechanical Sub-Assemblies)
h ƻ ƻ ƻ ƻ ƻ
ƻ˖ 㸼⼎䆹
↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼
SJ/T11363-2006 󰵼ޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T11363-2006 standard.
h˖ 㸼⼎
↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎ6-7󰵼ޚ㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials
in the parts is above the relevant threshold of the SJ/T11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ
This table shows where these substances may be found in the supply chain of electronic information
products, as of the date of sale of the enclosed product.
ℸ󰵼ᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳ󰵼ᖫᶤѯ䳊䚼ӊӮ
ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ
՟བ⬉∴ܗ῵ഫ䌈೼݊ѻકϞ
ֱ
⦃Փ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰
The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are
per the symbol shown here. The Environment- Friendly Use Period is valid only when the
product is operated under the conditions defined in the product manual.
200202320G
TRA
REGISTERED No:
DEALER No:
DA0039425/10
0019614/09


Product specificaties

Merk: Aruba
Categorie: Access point
Model: Instant AP-104

Heb je hulp nodig?

Als je hulp nodig hebt met Aruba Instant AP-104 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Access point Aruba

Handleiding Access point

Nieuwste handleidingen voor Access point