APSystems QT2 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor APSystems QT2 (26 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/26
Please scan this QR code to have
access to our APPs and Products
information
APsystems QT2 Microinverter
(For EMEA)
APsystems Microinverter Installation manual
©All Rights Reserved
ALTENERGY POWER SYSTEM Inc.
emea.APsystems.com
APsystems
Karspeldreef 8, 1101 CJ, Amsterdam, The Netherlands
EMAIL: info.emea@APsystems.com
APsystems
22 Avenue Lionel Terray 69330 Jonage France
EMAIL:info.emea@APsystems.com
APsystems Microinverter QT2 Installation manual
Table of Contents
1. Important Safety Instructions ......................................................................................................... 2
1.1 Safety Instructions .......................................................................................................................................... 2
1.2 Radio Interference Statement ........................................................................................................................ 3
1.3 Symbols in lieu of words.................................................................................................................................4
2. APsystems Microinverter System Introduction ..............................................................................5
3. APsystems Microinverter QT2 Introduction ................................................................................... 7
4. APsystems Microinverter System Installation ................................................................................ 8
4.1 Additional accessories supplied by APsystems ..............................................................................................8
4.2 Other required accessories not supplied by APsystems ............................................................................... 8
4.3 Installation Procedures ...................................................................................................................................9
4.3.1 Step 1 - Verify that grid voltage matches microinverter rating.......................................................... 9
4.3.2 Step 2 – AC Bus Cable distribution ......................................................................................................9
4.3.3 Step 3 - Attach the APsystems Microinverters to the Racking ........................................................... 9
4.3.4 Step 4 - Ground the system...............................................................................................................10
4.3.5 Step 5 - Connect the APsystems microinverter to AC bus cable ...................................................... 10
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable ...................................................... 11
4.3.7 Step 7 - Connect APsystems Microinverters to the PV Modules ......................................................12
4.3.8 Step 8 - Connect APsystems Microinverters to Grid .........................................................................13
4.3.9 Step 9 - AC Extension Cable .............................................................................................................. 13
4.3.10 Step 10 - Complete the APsystems installation map ...................................................................... 14
4.3.11 Step 11 - Warning Notice ................................................................................................................ 14
5. APsystems microinverter system operating instructions .............................................................15
6. Troubleshooting .............................................................................................................................16
6.1 Status Indications and Error Reporting ........................................................................................................ 16
6.1.1 Start up LED ....................................................................................................................................... 16
6.1.2 Operation LED ................................................................................................................................... 16
6.1.3 GFDI Error .......................................................................................................................................... 16
6.2 ECU_APP ....................................................................................................................................................... 16
6.3 Installer EMA (web portal or EMA Manager APP) ....................................................................................... 16
6.4 Trouble Shooting Guide ................................................................................................................................16
6.5 APsystems Technical Support ....................................................................................................................... 17
6.6 Maintenance .................................................................................................................................................17
7. Replace a microinverter ................................................................................................................ 18
8. Technical Data................................................................................................................................19
8.1 QT2 3-Phase Microinverter Datasheet .........................................................................................................20
9. QT2 - Wiring Diagram .................................................................................................................... 21
9.1 QT2 Connected To Detla Type 3-Phase Grid ................................................................................................ 21
9.2 QT2 Connected To Wye 3-Phase Grid .......................................................................................................... 22
10.QT2 Accessory ...............................................................................................................................23
10.1 Dimensions ................................................................................................................................................. 23
10.2 Wiring Diagram ...........................................................................................................................................24
11.APsystems Microinverter Installation Map ................................................................................. 25
APsystems Microinverter QT2 Installation manual
2
1. Important Safety Instructions
This manual contains important instructions to follow during installation and maintenance of the APsystems
Photovoltaic Grid-connected Microinverter. To reduce the risk of electrical shock and ensure a safe installation
and operation of the APsystems Microinverter, the following symbols appear throughout this document to
indicate dangerous conditions and important safety instructions.
Specifications are subject to change without notice. Please ensure you are using the most recent update found at
https://emea.apsystems.com/resources/library/
This indicates a situation where failure to follow instructions may cause a serious hardware failure or
personnel danger if not applied appropriately. Use extreme caution when performing this task.
This indicates information that is important for optimized microinverter operation. Follow these
instructions closely.
1.1 Safety Instructions
Only qualified professionals should install and/or replace APsystems Microinverters.
Perform all electrical installations in accordance with local electrical codes.
Before installing or using the APsystems Microinverter, please read all instructions and cautionary markings
in the technical documents and on the APsystems Microinverter system and the solar array.
Do NOT disconnect the PV module from the APsystems Microinverter without first disconnecting the AC
power.
Be aware that the body of the APsystems Microinverter is the heat sink and can reach a temperature of 80°C.
To reduce risk of burns, do not touch the body of the Microinverter.
Do NOT attempt to repair the APsystems Microinverter. If the microinverter is suspected to be faulty, please
contact your local APsystems Technical Support to start troubleshooting and obtain a RMA (Return
Merchandise Authorization) number to start the replacement process if needed. Damaging or opening the
APsystems Microinverter will void the warranty.
Caution!
When connecting a microinverter, it is recommended to first connect the AC Bus cable to the ground then
connect the AC connector to ensure proper earthing of the microinverter, then do the DC connections.
When disconnecting a microinverter disconnect the AC by opening the branch circuit breaker first but
maintain the protective earthing conductor in the branch circuit breaker connected to the microinverter,
then disconnect the DC inputs.
Please install AC breakers on the AC side of the microinverter.


Product specificaties

Merk: APSystems
Categorie: Niet gecategoriseerd
Model: QT2

Heb je hulp nodig?

Als je hulp nodig hebt met APSystems QT2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd APSystems

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024