User Manual English
Smart-UPS 2200/3000 VA XL 120/208/230 VAC Tower/Rack-Mount 5U User Manual 3
Introduction
About this UPS
The American Power Conversion (APC®) Uninterruptible Power Supply (UPS) provides protection for
electronic equipment from utility power blackouts, brownouts, sags and surges. The UPS filters small utility
line fluctuations and isolates electronic equipment from large disturbances by internally disconnecting from
utility line power. The UPS provides continuous power from the internal battery until utility power returns to
safe levels or the battery is fully discharged.
Unpack
Read the Safety Guide before installing the UPS.
Inspect the UPS upon receipt. Notify the carrier and dealer if there is damage.
The packaging is recyclable; save it for reuse or dispose of it properly.
Check the package contents:
Specifications
NOTE: The model and serial numbers are located on a small, rear panel label. For some models, an additional label
is located on the chassis under the front bezel.
•UPS
•Front bezel
•Literature kit containing:
– EPO connector
– Serial cable
– USB cable
– Eight ornamental screws for
securing the unit in the rack
– Eight 5/16 in (.8 cm) pan-head
screws for attaching cleats to the
chassis rails
(required for four post rack only)
– Eight 5/8 in (1.6 cm) pan-head
screws for attaching rack-mount
brackets to the unit
– Eight snap-on speed nuts
– Two rail cleats (required for four post
rack only)
– Two rack-mount brackets
– Product documentation
– Smart-UPS® User Manuals CD
– PowerChute® Business Edition CD
– Safety information
– Warranty information
Additional contents for
230 V models:
– APC power cable
– Alternate input power cord
(UK customers)
– IEC Power cord
– IEC jumper cables
Temperature
Operating
Storage
32° to 104° F (0° to 40° C)
5° ° to 86° F (-15° to 30 C) charge the UPS battery every six months
86° to 113 C) charge the UPS battery every three months° F (30° to 45
°
This unit is intended for indoor use
only. Select a location sturdy enough
to handle the weight.
Do not operate the UPS where there
is excessive dust or the temperature
or humidity are outside the specified
limits.
Environmental factors impact battery
life. High temperatures, poor utility
power, and frequent, short duration
discharges will shorten battery life.
Maximum
Elevation
Operating
Storage 10,000 ft (3,000 m)
50,000 ft (15,240 m)
Humidity 0 to 95% relative humidity, non-condensing
Weight 142 lbs (64 kg) with battery module
89 lbs (40 kg) without battery module
27 lbs (12 kg) each battery module
142 lbs (64 kg)
Maximum Number of External Battery Packs Supported by the
Smart-UPS XL
10


Product specificaties

Merk: Apc
Categorie: UPS
Model: SUA3000XLI
Gewicht: 55000 g
Geluidsalarm(en): Ja
Uitgangsvermogen: 2700 W
Afmetingen (B x D x H): 196 x 503 x 432 mm
Batterijtechnologie: Sealed Lead Acid (VRLA)
Surge energy rating: 480 J
Nominale input voltage: 230 V
Input-connectietype: IEC-320 C20
Output power capacity: 3 kVA
Typische backup tijd op halve lading: 13.6 min
Typische backup tijd op volledige lading: 5.5 min
Netspanning, in bedrijf: 230 V
Emergency Power Off (EPO): Ja
Output-aansluitingen: - (8) 320 C13 \t\n- (1) 320 C19 \t
Output Voltage voetnoot: 220: 230 / 240