Apc Smart-UPS SRTRK4 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Apc Smart-UPS SRTRK4 (8 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/8
Installation Guide Smart-UPSâ„¢On-Line
SRTRK4 Tower to Rack-Mount Conversion
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged.
SRTRK4 is compatible with all the variants of the following models:
• SRT1000
• SRT1500
• SRT2200
• SRT3000
Note: UPS and External Battery Pack (XLBP) models may differ in appearance from those depicted in these graphics.
The installation process is identical for all models.
One Rail Kit with instructions and
hardware for installing rails in a rack.
• 1 pair of rack-mount brackets
• 6 flat head screws to secure rack-mount brackets to the UPS
• 4 ornamental screws to secure rack-mount brackets to the rails
• 1 pair of rail cleats
• 8 screws to secure cleats to the UPS
su04
34a
x4
x6
x8
Smart-UPS On-2 Line SRTRK4 Tower to Rack-Mount Conversion2
Tower to Rack-Mount Conversion of UPS
CAUTION
DAMAGE TO EQUIPMENT OR PERSONNEL
• The equipment is heavy. Each APCRBC152 battery module weighs 16.4 kg (36.2 lbs) and each APCRBC141
battery module weighs 12.5 kg (27.6 lb). Each APCRBC155 battery module weighs 11 kg (24.25 lb).
• Always practice safe lifting techniques adequate for the weight of the equipment.
• Remove the battery modules before installing the UPS.
• Use the battery module handle to carefully slide the battery module in or out of the unit.
• Do not use the battery module handle to lift or carry the battery module.
• Place the UPS on a table to remove the stabilizer brackets.
• Always install the UPS at the bottom of the rack.
• Always install the XLBP below the UPS in the rack.
Failure to follow these instructions can result in equipment damage and minor or moderate injury.
 
 
suo0875b
suo0874b
suo0873b
x3
suo0872b
Smart-UPS On-2 Line SRTRK4 Tower to Rack-Mount Conversion 3
Install UPS in Rack
Refer to the Rail Kit Installation Guide for instructions on rail installation.
 
CAUTION
DAMAGE TO EQUIPMENT OR PERSONNEL
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
• Always use the recommended number of screws to secure brackets to the UPS.
• Always use the recommended number of screws to secure the UPS to the rack.
• Always install the UPS at the bottom of the rack.
• Always install the XLBP below the UPS in the rack.
Failure to follow these instructions can result in equipment damage and minor or moderate injury
 
suo0871b
su0845b
suo
0866e
x3
x3
x4
suo0867a
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Smart-UPS SRTRK4 |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Smart-UPS SRTRK4 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024