Important Safety Information
SAVE THESE INSTRUCTIONS - This manual contains important
instructions that should be followed during installation and maintenance of the
Back-UPS and batteries.
Read these instructions carefully and look at the equipment to become familiar
with the device before trying to install, operate, service or maintain it. The
following special messages may appear throughout this document or on the
equipment to warn of potential hazards or to call attention to information that
clarifies or simplifies a procedure.
The addition of this symbol to either a ā€œDangerā€ or ā€œWarningā€
safety label indicates that an electrical hazard exists which will
result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical
injury.
User Manual Back-UPSā„¢
BE650G2-IT and BE850G2-IT
Back-UPS BE650G2-IT/BE850G2-IT2
Product Handling Guidelines
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there
is any damage.
ā€¢ This UPS is for indoor use only.
ā€¢ Do not operate this UPS in direct sunlight, in contact with fluids, or
where there is excessive dust or high humidity.
ā€¢ Do not operate the UPS near open windows or doors.
ā€¢ Be sure the air vents on the UPS are not blocked. Allow adequate space
for proper ventilation.
Note: Allow a minimum of 20 cm clearance on both front and rear sides
of the UPS.
ā€¢ Environmental factors impact battery life. Elevated ambient
temperatures, poor quality utility power, and frequent discharges will
shorten battery life. Follow the battery manufacturer recommendations.
ā€¢ Connect the UPS power cable directly to a wall outlet. Do not use surge
protectors or extension cords.
ā€¢ The UPS cord shall be connected to an earthed mains socket outlet for
safety reasons.
Battery safety
ā€¢ Servicing of batteries should be performed or supervised by personnel
knowledgeable about batteries and required precautions.
ā€¢ APC by Schneider Electric uses Sealed Maintenance-Free Lead Acid
batteries. Under normal use and handling, there is no contact with the
internal components of the batteries. Over charging, over heating or
other misuse of batteries can result in leakage of battery electrolyte.
Released electrolyte is toxic and may be harmful to the skin and eyes.
ā€¢ CAUTION: Before installing or replacing the batteries, remove
conductive jewelry such as chains, wrist watches, and rings.
High energy through conductive materials could cause severe burns.
<18 kg
<40 lb
18-32 kg
40-70 lb
32-55 kg
70-120 lb
>55 kg
>120 lb
Back-UPS BE650G2-IT/BE850G2-IT 3
ā€¢ CAUTION: Do not dispose of batteries in a fire. The batteries may
explode.
ā€¢ CAUTION: Do not open or mutilate batteries. Released material is
harmful to the skin and eyes and may be toxic.
ā€¢ CAUTION: A battery can present a risk of electrical shock and high
short-circuit current. Failed batteries can reach temperatures that exceed
the burn thresholds for touchable surfaces. The following precautions
should be observed when working on batteries:
ā€“ Disconnect the charging source prior to connecting or disconnecting
battery terminals.
ā€“ Do not wear any metal objects including watches and rings.
ā€“ Do not lay tools or metal parts on top of batteries.
ā€“ Use tools with insulated handles.
ā€“ Wear rubber gloves and boots.
ā€“ Determine if battery is either intentionally or inadvertently grounded.
Contact with any part of a grounded battery can result in electric shock
and burns by high short-circuit current. The risk of such hazards can be
reduced if grounds are removed during installation and maintenance
by a skilled person.
Inventory
Connect the Battery
Back-UPS Quick start guide
ļ€±Remove the ā€œStop! Connect Batteryā€ label from the top cover.
ļ€²Invert the Back-UPS. Press the battery
compartment cover and release the
tabs. Slide open the battery cover.
bu491a
bu492a


Product specificaties

Merk: Apc
Categorie: UPS
Model: BE650G2-IT
Kleur van het product: Zwart
Gewicht: 4000 g
Breedte: 130 mm
Diepte: 365 mm
Hoogte: 120 mm
Snoerlengte: 1.83 m
Geluidsniveau: 45 dB
Gewicht verpakking: 4500 g
Breedte verpakking: 186 mm
Diepte verpakking: 441 mm
Hoogte verpakking: 190 mm
Gebruikershandleiding: Ja
LED-indicatoren: Ja
Vormfactor: Compact
USB-poort: Ja
Aantal Ethernet LAN (RJ-45)-poorten: 1
Certificering: CE, EAC
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Bekabelingstechnologie: 10/100Base-T
Uitgangsvermogen: 400 W
Accu/Batterij oplaadtijd: 16 uur
Temperatuur bij opslag: -15 - 45 Ā°C
Frequentie: 47/63 Hz
Luchtvochtigheid bij opslag: 0 - 95 procent
Hoogte bij opslag: 0 - 4500 m
Efficientie: 80 procent
Bedrijfstemperatuur (T-T): 0 - 40 Ā°C
Relatieve vochtigheid in bedrijf (V-V): 0 - 90 procent
Code geharmoniseerd systeem (HS): 85078000
Surge energy rating: 310 J
Golf protectie functies: Digital Subscriber Line (DSL)
Stroom (max.): 6 A
Output power capacity: 0.65 kVA
Ingang operation voltage (min): - V
Ingang operation voltage (max): - V
Uitgang operation voltage (min): 220 V
Uitgang operation voltage (max): - V
UPS-topologie: Stand-by (Offline)
Hot-swap batterij: Ja
Output frequentie: 47/63 Hz
Hoorbare alarmstanden: Alarm when on battery, Low battery alarm, Overload alarm
Spanningsbeveiliging: Ja
Golfvorm: Sinus
Koude start: Ja
Automatische batterij test: Ja
Acculevensduur (max): 5 jaar