Apc Smart-UPS SRTL004 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Apc Smart-UPS SRTL004 (4 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/4
Installation Guide APC™ Smart-UPS™ Ultra
Power Distribution Unit (PDU)
SRTL002/SRTL003/SRTL004/SRTL005
Important Safety Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during
installation and maintenance of the Smart-UPS and batteries.
Read the user documentation to become familiar with the equipment before trying to install or operate
it.
The following special messages may appear throughout this bulletin or on the equipment to warn of potential
hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol either to a “Danger” or “Warning” safety label indicates that an electrical
hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
APC Smart-UPS Ultra SRTL002/SRTL003/SRTL004/SRTL0052
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if there is damage.
PDU Replacement
The PDU in the following illustration is only for representation. The procedure is applicable for all the PDUs,
SRTL002, SRTL003, SRTL004, and SRTL005.
Removal of the existing PDU
Hardwiring PDU (SRTL002) PDU with 2x L6-30 and 2x L6-20 receptacles
(SRTL005)
IEC PDU (SRTL003)
PDU with 4x L6-20 receptacles (SRTL004)
CAUTION
RISK OF DAMAGE TO EQUIPMENT OR PERSONNEL
• PDU must replaced by a qualified electrician or a service personnel.
• Adhere to all local and national electrical codes.
Failure to follow these instructions could result in equipment damage and minor or moderate injury.
Turn off the UPS Output (refer to the UPS Operation Manual for details) by selecting the Turn Off Immediately
option.
Turn off the input power to the UPS at the wall socket.
Loosen the thumbscrew and turn off the BATTERY /ON OFF switch, on the internal battery module in the UPS.
Disconnect XLBPs connected to the UPS, if any.
Unplug all the connected equipment from the output sockets of the UPS.
Locate the screws securing the standard PDU to the
UPS and unfasten them using a Torx® T20 driver bit.
Slide the PDU to the left to align the locking pin with
the keyhole.
4X
APC Smart-UPS Ultra SRTL002/SRTL003/SRTL004/SRTL005 3
Installation of the replacement PDU
a. Pull out the PDU.
b. Remove the clips (on the top and the bottom)
securing the connectors and pull the connectors
apart..
Locate the screw securing the ground wire to the
ground terminal and unfasten it.
a. Connect the ground wire of the replacement PDU
to the ground terminal.
b. Insert the PDU connector into the UPS connector
and install the top and bottom clips to secure the
connectors.
Align the locking pin on the UPS and the key hole on
the PDU and insert the PDU.
Slide the PDU to the right to lock the PDU in position. Secure the PDU to the UPS by fastening the screw
using a Torx® T20 driver bit.
NOTE: This step is applicable only for SRTL002.
Hardwire the PDU. Refer to “Hardwiring” on page 4 for details.
Re-connect all the connected equipment to the output sockets of the UPS.
Re-connect the XLBPs to the UPS, if any.
Turn on the BATTERY /ON OFF switch in the internal battery module and tighten the thumbscrew on the internal
battery module completely.
Turn on the input power to the UPS at the wall socket.
Turn on the UPS output (refer to the UPS Operation Manual for details).
4X
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Smart-UPS SRTL004 |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Smart-UPS SRTL004 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024