Smart-UPSâ„¢On-Line Isolation and
Step-Down Transformer SRT5KTF
Safety Messages
Read the instructions carefully to become familiar with the equipment before attempting to install, operate, service or
maintain the transformer. The following special messages may appear throughout this manual or on the equipment to
warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard
exists that will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
Safety Information
• Adhere to all national and local electrical codes.
• All wiring must be performed by a qualified electrician.
• Changes and modifications to this unit not expressly approved by APC could void the warranty.
• This transformer is intended for indoor use only.
• Do not operate this transformer in direct sunlight, in contact with fluids, or where there is excessive dust or
humidity.
• Be sure the air vents on the transformer are not blocked. Allow adequate space for proper ventilation.
• For a transformer with a factory installed power cord, connect the transformer power cable directly to an output
receptacle of the UPS. Do not use surge protectors or extension cords.
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
• For rack mount transformers, always install the transformer directly above the UPS in rack-mount configurations.
The UPS must be installed below the transformer.
• Always install peripheral equipment above the UPS in rack-mount configurations.
• Additional safety information can be found in the Safety Guide supplied with this unit.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
Isolation and Step-Down Transformer SRT5KTF2
Electrical safety
• For models with a hardwired input, the connection to the branch circuit (mains) must be performed by a
qualified electrician.
• 230 V models only: In order to maintain compliance with the EMC directive for products sold in Europe, output
cords attached to the transformer must not exceed 10 meters in length.
• The protective earth conductor for the transformer carries the leakage current from the load devices (computer
equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the
transformer. The conductor must have the same size and insulation material as the grounded and ungrounded
branch circuit supply conductors. The conductor will typically be green and with or without a yellow stripe.
• The UPS input ground conductor must be properly bonded to protective earth at the service panel.
• If the UPS input power is supplied by a separately derived system, the ground conductor must be properly
bonded at the supply transformer or motor generator set.
Hardwire safety
• Verify that all branch circuit (mains) and low voltage (control) circuits are deenergized, and locked out before
installing cables or making connections, whether in the junction box or to the transformer.
• Wiring by a qualified electrician is required.
• Check national and local codes before wiring.
• All openings that allow access to transformer hardwire terminals must be covered. Failure to do so may result in
personal injury or equipment damage.
• Select wire size and connectors according to national and local codes.
General information
• The model and serial numbers are located on a small, rear panel label.
• Recycle the package materials or save them for reuse.
FCC Class A radio frequency warning
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are intended to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Product Information
The Smart-UPSâ„¢ SRT transformer is intended for use as a step-down transformer. This transformer can also function as
an isolation transformer.
The transformer can be installed in a standard 19-inch rack.
The transformer can be installed as a tower or in a rack. For rack-mount configuration use only the APC by Schneider
Electric rack model SRTRK2.
Isolation and Step-Down Transformer SRT5KTF 3
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if the unit is damaged.
Specifications
For additional specifications refer to the APC by Schneider Electric web site, www.apc.com.
Environmental
Physical
Use with all
models
Use with
SRT5K/6K/8K/10K UPS Use with SRT3000XLT UPS
Front bezel 1 tie bracket to secure the UPS to
the transformer
2 screws to secure tie bracket
1 tie bracket to secure the UPS to
the transformer
1 pan head screw to secure tie
bracket
Top and bottom tie brackets to
secure the UPS with transformer
2 pan head screws to secure tie
brackets
2 tie brackets to secure the UPS to
the transformer
Temperature Operating 0º to 40º C (32º to 104º F)
Storage -15º to 45º C (5º to 113º F)
Maximum Elevation Operating 0 - 3,000 m (0 - 10,000 ft)
Storage 0 - 15,000 m (50,000 ft)
Humidity 0% to 95% relative humidity, non condensing
Protection Class IP 20 rating
Lifting guidelines 32 - 55 kg (70 - 120lb) > 55 kg (> 120lb)
Unit weight, without packaging 56.82 kg (125 lb)
Unit weight, with packaging 63.64 kg (140 lb)
Unit dimensions without packaging
Height x Width x Depth
432 mm x 130 mm x 660 mm
17 in x 5 in x 26 in
Unit dimensions with packaging
Height x Width x Depth
347 mm x 603 mm x 980 mm
13.68 in x 23.74 in x 38.6 in
The model and serial numbers are on a small label located on the rear panel.