Installation Guide Smart-UPS™ On-Line
External Battery Pack XBP48RM2U-LI
Important Safety Messages
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during
installation and maintenance of the External Battery Pack (XLBP).
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or
maintain it. The following special messages may appear throughout this manual or on the equipment to warn of
potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol either to a “Danger” or “Warning” safety label indicates that an electrical
hazard exists which will result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety
messages that follow this symbol to avoid possible injury or death.
Product Handling Guidelines
Safety and General Information
• Adhere to all national and local electrical codes.
• Changes and modifications to this unit not expressly approved by APC by Schneider Electric could void the
warranty.
• This unit is intended only for indoor use in a controlled environment.
• Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
• Allow adequate space for proper ventilation.
• The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
<18 kg
<40 lb
18-32 kg
40-70 lb
32-55 kg
70-120 lb
>55 kg
>120 lb
Smart-UPS On-Line External Battery Pack XBP48RM2U-LI2
• Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs.
• UPS models will recognize external battery packs connected to the UPS. Refer to the user documentation of
your UPS model for information about the maximum number of battery packs that can be connected.
NOTE: For each XLBP added, increased recharge time will be required.
• Always recycle used batteries.
• Recycle the package materials or save them for reuse.
Battery safety
• Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the
required precautions. Keep unauthorized personnel away from batteries.
• Schneider Electric uses Lithium Ion batteries. Under normal use and handling, there is no contact with the
internal components of the battery.
• The battery typically lasts for eight to ten years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality mains power causing frequent short duration discharges will shorten battery life.
• CAUTION: Before installing or replacing the batteries, remove conductive jewelry such as chains, wrist
watches and rings. High energy through conductive materials could cause severe burns.
• CAUTION: Do not place or use the battery pack near heat or fire.
Do not crush, do not dispose off a battery pack in a fire. The batteries may explode.
• CAUTION: Do not open the battery pack enclosure. Doing so will expose the cell terminals which pose an
energy hazard.
• CAUTION: Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
It may be toxic.
• CAUTION: A battery can present a risk of electric shock and burns by high short-circuit current. The following
precautions should be observed when working on batteries:
– Disconnect the charging source prior to connecting or disconnecting battery terminals.
– Do not wear any metal objects including watches and rings.
– Do not lay tools or metal parts on top of batteries.
– Use tools with insulated handles.
– Wear rubber gloves and boots.
– Determine if battery is either intentionally or inadvertently grounded. Contact with any part of a grounded
battery can result in electric shock and burns by high short-circuit current. The risk of such hazards can be
reduced if grounds are removed during installation and maintenance by a skilled person.
• CAUTION: Failed batteries can reach temperatures that exceed the burn thresholds for touchable surfaces.
• Do not use a dropped, damaged or deformed battery pack.
• Do not short circuit battery pack.
• Do not drive nails into the battery pack.
• Do not strike the battery pack with a hammer.
WARNING
RISK OF CHEMICAL HAZARD AND EXCESSIVE SMOKE
• Replace the battery at least every 10 years or at the end of its service life, whichever is earlier.
• Replace the battery immediately when the UPS indicates battery replacement is necessary.
• Replace batteries with the same type of batteries as originally installed in the equipment.
Failure to follow these instructions can result in death or serious injury.
Smart-UPS On-Line External Battery Pack XBP48RM2U-LI 3
Overview
• To verify that installation of an external battery pack (XLBP) has been successful, go to the UPS display
interface.
Perform a Visible Alarm Test to determine if the XLBP is recognized by the UPS.
The green LED on the XLBP will illuminate if successful communication has been established.
• When viewing the status of an XLBP on the UPS display interface screen, the LED on the corresponding XLBP
will flash.
Package Contents
Inspect the contents upon receipt. Notify the carrier and dealer if there is
damage.
Specifications
For additional specifications, refer to the APC by Schneider Electric web site at www.apc.com.
Environmental
Physical
Ground cable
Pan head
screws to secure the ground
cable x2
Cleats
Pan head screws to
secure the cleats x8
Rail Kit with instructions and hardware
for installing rails in a rack
• A pair rack-mount brackets
• Flat head screws to secure
rack-mount brackets to the XLBP x6
• Ornamental screws to secure the rack-
mount bracket to the rack x4
Flat head screws to secure tie
bracket p3-x4
Tie bracket x2
Communication
cable
Pan head screw to secure the
XLBP battery cable connector
to an XLBP or to the UPS.
Stabilizer foot
extension 1U x4
Temperature Operating 0 to 40 °C (32 to 104 °F)
Storage -15 to 45 °C (5 to 113 °F)
Elevation Operating 0 - 3,000 m (0 - 10,000 ft)
Storage 0 - 15,000 m (49,212 ft)
Humidity 0 to 95% relative humidity, non- condensing
International Protection Code IP20
Note: Charge the XLBPs immediately upon receipt / first installation and at least once in six months during storage or when
not in use.
The battery pack is heavy. Follow all lifting guidelines.
Unit weight, without packaging 27 kg (59.52 lb)
Unit weight, with packaging 30 kg (66.14 lb)
Unit dimensions without packaging
Height x Width x Depth
85.50 x 432 x 521 mm
(3.37x 17.00 x 20.51 in)
Unit dimensions with packaging
Height x Width x Depth
180 x 540 x 800 mm
(7.09 x 21.26 x 31.50 in)
The model and serial numbers are on a small label located on the rear panel.
x6
x4
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Smart-UPS Battery Systems XBP48RM2U-LI |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Smart-UPS Battery Systems XBP48RM2U-LI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024