UN38.3 Test Report Summary β CP12142LI 1to 4
Version: 1.1
Date: November 11, 2019
UN38.3 Lithium Ion Battery Test Summary
Version: 1.1
Revision date: November 11, 2019
1.0 Products covered by this Test Summary
Model Number
Description
Notes
CP12142LI
Network UPS 12Vdc. Lithium Battery,19500mAh,
BMS, 4LED
Physical Description of Products
Product is a 142 WH Network Power Supply with a
lithium ion battery to extend runtime of Network
Gateway Devices
1.1 Batteries in Products
#
Model Number
Description
Notes
1
CP12142LI
Network UPS 12Vdc. Lithium Battery,19500mAh,
BMS, 4LED
2
1.2 Cells in Batteries
#
Model Number
Description
Notes
3
LGGBF1L1865
(INR18650F1L)
INR18650F1L (3350mAh, 3.63V ) Lithium-Ion
Battery
12.1605 WH
4
2.0 Manufacturers of Cells/Batteries
2.1 Battery/Cell Maker #1
Name
Address
Phone
Website
C- TECH United Corp
5F, No. 663,665,
Zhongzheng Rd.
New Taipei City, 24257 Taiwan
+886-2-
29016600
www.c-
techone.com
NOTES: Battery Pack Maker
2.1 Battery/Cell Maker #3
Name
Address
Phone
Website
LG CHEMICAL LIMITED
Twin Tower Youido-Dong,
Youngdeungpo- Ku, Seoul, KOREA
www.lgchem.com
NOTES: Cell Maker β
UN38.3 Test Report Summary β CP12142LI 2to 4
Version: 1.1
Date: November 11, 2019
3.0 Test Laboratories of Cells / Batteries
3.1 Battery/Cell Maker #1
Name
Address
Phone
Website
Shenzen CCJC
Technology Co., Ltd.
1st Floor, Xinbaoyi Industry and
Trade Building B, Houting
Community, Shajing Town,
Baoβan District, Shenzhen City,
Guangdong China
+ -0755
23707853
www.ccjctek.com
Test ID No:
CCJC2017A2445
Date:
2017 11 06- -
NOTES:
Lithium Ion Cell
Lithium Metal Cell
XXX
Lithium Ion Battery
Lithium Metal Battery
3.1 Battery/Cell Maker #3
Name
Address
Phone
Website
Test ID No:
Date:
NOTES:
Lithium Ion Cell
Lithium Metal Cell
Lithium Ion Battery
Lithium Metal Battery
4.0 Parameters of Cells/Batteries
Parameters
Cell
Battery
Mass in gram (g)
49
747
Lithium ion Indicate watt-hour rating (Wh)
12.1605 WH
142 Wh
Lithium metal Indicate lithium metal content in gram (g)
N/A
N/A
Physical Description of Cells / Batteries
Battery Pack is a plastic encased cartridge
containing 12 cells in 2S6P configuration.
UN38.3 Test Report Summary β CP12142LI 3to 4
Version: 1.1
Date: November 11, 2019
5.0 List of tests conducted and results
Test
Pass
Fail
N/A
T1 β Altitude simulation
X
T2 β Thermal Tests
X
T3 β Vibration
X
T4 β Shock
X
T5 β External Short Circuit
X
T6 β - Impact for cylindrical cells having a diameter of at
least 18mm. See Section 6.0
X
T6 β - Crush for prismatic cells, pouch cells, button cells
and cylindrical cells having a diameter of less than 18mm.
See Section 6.0
X
T7 β Overcharge
X
T8 β Forced Discharge
X
6.0 UN38.3 Test Conformation for the Cells inside the battery:
Cell UN 38.3 Test
Confirmed (Yes or No)
When no separate document for the cells is provided, this confirms
that the cells inside the battery have successfully passed the UN
38.3 test. In this case under section 5.0 the T6 and T8 must be
marked as βpassedβ and here under section 6.0 βCell UN 38.3 Test
confirmedβ needs to be Yes.
YES
7 .0 Reference to assembled battery testing requirements
Not Applicable
YES
8 .0 Reference to the edition on the Manual of Tests and Criteria applied
ST/SG/
ST/SG/
ST/SG/
ST/SG/ST/SG/AC.10
AC.10
AC.10
AC.10AC.10/11/R
/11/R
/11/R
/11/R/11/Rev.5/Am
ev.5/Am
ev.5/Am
ev.5/Amev.5/Amend.2
end.2
end.2
end.2end.2 UN38
UN38
UN38
UN38 UN38.3
.3
.3
.3.3
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Back-UPS Connect CP12142LI |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Back-UPS Connect CP12142LI stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024