Inventory
Important Safety Instructions
Inspect the package contents upon receipt. Notify the carrier and
dealer if there is any damage.
SAVE THESE INSTRUCTIONS - This section contains important instructions that
should be followed during installation and maintenance of the UPS and batteries.
Connect the UPS power cable directly to a wall outlet.
The UPS is intended for indoor use only.
CAUTION: A battery can present a risk of electric shock and burns by high
short-circuit current.
CAUTION: Failed batteries can reach temperatures that exceed the burn thresholds
for touchable surfaces.
Do not operate the UPS in direct sunlight, in contact with fluids, or where there is
excessive dust and humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected equipment when the
Back-UPS is turned on and connected to AC power. Battery backup outlets receive
power from the battery for a limited period of time when a power outage, or brownout
condition occurs. Battery backup outlets provide protection from power surges or
spikes. Connect a computer, monitor and other peripheral devices to these outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the
Back-UPS is connected to AC power, and is switched on or off. Surge protection
outlets provide protection from power surges or spikes. Connect peripheral devices
(such as printer, scanner, etc.) that do not need to remain on during power outages or
AC problems to the surge protection outlets.
USB charging port
The USB port provides a maximum of 1.5A DC power. The USB port will provide
power when the unit is on AC and on battery.
Turn On the Back-UPS
Press the POWER button located on the top of the Back-UPS. The POWER button will
illuminate green and a single short beep will indicate that the Back-UPS is on and
providing protection for connected equipment.
The Back-UPS battery charges fully during the first 24 hours while connected to AC
power. The Back-UPS battery will charge regardless of whether the Back-UPS is
switched on or off as long as it is connected to AC power. The UPS will have full
runtime capability after the initial 24 hour charging period.
If the red Building Wiring Fault indicator (located on the end near the power cord) is
lit, your building wiring may present a shock hazard that should be corrected by a
qualified electrician.
Turn Off the Back-UPS
To turn off the Back-UPS, press the POWER button for at least 2 seconds. At the first
beep, release the button and the UPS will turn off. A 2 second delay has been added to
mitigate unintentional contact with the POWER button.
Quick Mute
The Back-UPS is able to temporarily mute user correctable alarms such as: On
Battery, Battery disconnected and Overload.
During such alarms, a short press (less than 2 seconds) of the POWER button will
temporarily mute the alarm until the condition has been reset. A short double beep will
confirm that Quick Mute has been activated. Pressing the POWER button for more than
2 seconds will turn off the UPS.
Other critical events such as Battery replacement and Charger notification can not be
temporarily muted. The unit in these cases must be turned off.
On Battery Indicator Modes
This Back-UPS has 3 On Battery Indicator modes provided that the UPS is turned on.
To configure an On Battery Indicator mode, hold down the POWER button and wait for
the third beep. At the third beep the POWER button will cycle red / green. Release the
POWER button and its color will indicate the mode the UPS is in. Press the POWER
button to cycle through each mode. See the table below for the mode selection colors.
Once the mode has been selected, wait 5 seconds and the setting will be committed to
the UPS.
PowerChute Personal Edition Software
Overview
Use PowerChute Personal Edition software to configure the UPS settings, protect your
computer and other equipment during a utility power outage. During a power outage,
PowerChute will save any open files on your computer and shut it down. When utility
power is restored, it will restart the computer.
Note: PowerChute is only compatible with a Windows operating system. If you are
using Mac OSX, use the native shutdown feature to protect your system. See the
documentation provided with your computer.
Installation
Use the USB cable to connect the Data port on the UPS to the USB port on your
computer. Download PowerChutePersonal Edition Software from www.apc.com/
pcpe. Select the appropriate operating system and follow directions to download the
software.
Status Indicators
CAUTION
RISK OF HYDROGEN SULPHIDE GAS AND EXCESSIVE SMOKE
Replace the battery at least every 5 years or at the end of its service life,
whichever is earlier.
Replace the battery immediately when the Easy UPS indicates battery
replacement is necessary.
Replace batteries with the same number and type of batteries as originally
installed in the equipment.
Replace the battery immediately when the UPS indicates a battery over-
temperature condition, or when there is evidence of electrolyte leakage.
Power off the Easy UPS, unplug it from the AC input, and disconnect the
batteries. Do not operate the Easy UPS until the batteries have been
replaced.
Failure to follow these instructions can result in minor or moderate
injury and equipment damage.
Remove the “Stop! Connect the Battery”
label that covers the outlets.
Press the battery compartment cover
release tabs located on the underside of the
unit. Slide the battery cover off.
Connect the battery cable securely to the
battery terminal. It is normal for small sparks
to be seen when the battery cable is connected
to the battery terminal.
Reinstall the battery compartment
cover. Be sure that the release tabs lock
into place.
bu446a
bu447a
bu448a
bu449a
bu450a
bu451f
POWER
Button
USB Charger
Battery Backup + Surge
Protection Outlets
Surge Protection
Outlets
bu452e
Building
Wiring
Fault
USB Data Port (PowerC hute)
AC Power
Inlet
Circuit
Breaker
Mode Visual
Indicator Audible Indicator Mode Selection
Color
Quiet Alarm
(default)
The POWER
button is solid
green and
flashes twice
every 2 seconds
until Low
Battery
notification
where it will
flash green in
rapid
succession.
No alarm until Low Battery
notification where the alarm beeps
twice every 30 seconds
Flashing green
No Alarm No alarm while the UPS is On
Battery
Flashing red
Full Alarm Alarm sounds 4 beeps every 30
seconds until Low Battery
notification where the alarm beeps
every half second. As the UPS
shuts down it sounds one beep
every 4 seconds
Flashing amber
Status Power Button
illumination
Audible
Indicator On
Audible
Indicator
Terminates
Power On
The Back-UPS is supplying AC
power to connected equipment.
Solid green None N/A
On Battery
Back-UPS supplying battery
power to battery backup outlets.
Solid green and
flashes twice
every 2 seconds.
The audible
alarm
depends on
the On
Battery
Indicator
mode setting.
See the On
Battery
Indicator
Modes
section for
full details.
Beeping stops
when AC power is
restored or the
Back-UPS is
turned off.
Applies only to
modes where the
on battery alarm is
audible.
Low Battery notification
The Back-UPS is supplying
battery power to the battery
backup outlets and the battery is
near a total discharge state.
Flashes green in
rapid succession.
Low Battery shutdown
The battery has been completely
discharged while the Back-UPS
is on battery, the UPS will shut
down.
None - AC power is
restored
- AC is not
restored within 32
seconds
- The Back-UPS is
turned off.
Sleep Mode
The UPS has shut down and will
“awakenonce AC power is
restored
None None N/A
Replace Battery
• The battery is disconnected.
• The battery needs to be charged, or
replaced.
• Flashes red only.
• Alternates green-
red
Constant tone
Constant tone
Back-UPS is
turned off
Overload Shutdown
An overload condition has
occurred in one or more of the
battery backup outlets while the
Back-UPS is operating on battery
power.
None Constant tone Back-UPS is
turned off
USB Detected Fault
A short circuit has been detected
or an error has occurred.
Alternates green-
amber
None N/A
User Manual Back-UPS BN600U1
© 2022 APC by Schneider Electric. APC, the APC logo, PowerChute and Back-UPS are owned by Schneider Electric Industries S.A.S., or their affiliated companies. All
other trademarks are property of their respective owners.
EN 990-91528A
01/2022
Voltage Sensitivity Adjustment (optional)
The Back-UPS detects and reacts to line voltage distortions by transferring to battery
backup power to help protect connected equipment. In situations where either the
Back-UPS or the connected equipment is too sensitive for the input voltage level it is
necessary to adjust the transfer voltage.
1. Turn off the UPS while connected to a wall outlet.
2. Press and hold the POWER button for 10 seconds. The POWER button LED will
illuminate green and red alternately to indicate that the Back-UPS is in Program
mode.
3. The POWER button will illuminate either green, amber, or red to indicate the current
sensitivity level. Refer to the table for an explanation of the transfer voltage
sensitivity levels.
4. To exit Program mode wait five seconds and all LED indicators will stop
illuminating. Program mode is no longer active.
Specifications
Service
If the unit requires service, do not return it to the dealer. Follow these steps:
1. Review the Troubleshooting section of the manual to eliminate common problems.
2. If the problem persists, contact Schneider Electric IT (SEIT) Customer Support
through the APC by Schneider Electric Web site, www.apc.com.
a. Note the model number and serial number and the date of purchase. The model
and serial numbers are located on the rear panel of the unit and are available
through the LCD display on select models.
b. Call SEIT Customer Support and a technician will attempt to solve the
problem over the phone. If this is not possible, the technician will issue a
Returned Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary internationally. Refer to the APC by
Schneider Electric Web site for country specific instructions.
3. Pack the unit in the original packaging whenever possible to avoid damage in
transit. Never use foam beads for packaging. Damage sustained in transit is not
covered under warranty.
4. Always DISCONNECT THE UPS BATTERIES before shipping. The United
States Department of Transportation (DOT), and the International Air
Transport Association (IATA) regulations require that UPS batteries be
disconnected before shipping. The internal batteries may remain in the UPS.
5. Write the RMA# provided by Customer Support on the outside of the package.
6. Return the unit by insured, pre-paid carrier to the address provided by Customer
Support
Replace Battery
Deliver the used battery to a recycling facility.
Replace the used battery with an APC by Schneider Electric approved
battery. Replacement batteries can be ordered through the APC by Schneider
Electric Web site, www.apc.com. Battery replacement part for Back-UPS
BN600U1 is APCRBC154.
APC by Schneider Electric IT Customer Support
Worldwide
For country specific customer support, go to the APC by Schneider Electric Web site,
www.apc.com.
Troubleshooting
Wall Mount Installation
Horizontal installation, use 2 screws 8.43” (214 mm) apart.
Allow 5/16” (8 mm), of the screw to protrude from the wall.
Warranty
Register your product on-line. http://warranty.apc.com
The standard warranty is three (3) years from the date of purchase. Schneider Electric IT
(SEIT) standard procedure is to replace the original unit with a factory reconditioned
unit. Customers who must have the original unit back due to the assignment of asset tags
and set depreciation schedules must declare such a need at first contact with an SEIT
Technical Support representative. SEIT will ship the replacement unit once the defective
unit has been received by the repair department, or cross ship upon the receipt of a valid
credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground
freight transportation costs to ship the replacement unit to the customer.
EMC Compliance
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that may cause undesired
operation.
Some models are compliant with California (CEC) Battery Charger
regulations. For more information, search for your model number on
www.apc.com and review the Conformance Approvals section of the
Technical Specifications.
LED
Flashes
Sensitivity
Setting
Input Voltage Range
(AC Operation) Recommended Use
Green LOW 88 Vac to 142 Vac Use this setting with equipment that is
less sensitive to fluctuations in voltage or
waveform distortions.
Red MEDIUM 92 Vac to 139 Vac Factory default setting. Use this setting
under normal conditions.
Amber HIGH 96 Vac to 136 Vac Use this setting when connected
equipment is sensitive to voltage and
waveform fluctuations.
Input
Voltage 120 Vac Nominal
Frequency 50/60 Hz + 3 Hz auto-sensing
Brownout Transfers 92 Vac Typical
Over-voltage
Transfer
139 Vac Typical
Output
UPS Capacity 600 VA, 330 W
Total Amperage (AC
outlets)
5.42 A
Voltage - On Battery 115 Vac ± 8%
Frequency - On
Battery
50/60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
USB
Port
* Charging Current 1.5 A
Charger
compatibility
USB Battery Charging Specification 1.2
* Power output is dependent power drawn by the connected device. Check
your device manufacturer to understand the maximum charging current for a
given USB spec.
Protection
and
Filtering
AC Surge Protection Full time, 490 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid 12 V
Average Life 3 - 5 years, the number of discharge cycles and
environmental temperature
Charging Time 10 hours. Using the USB port while charging the
battery will increase the amount of time required.
Physical
Net Weight 7.7 lb (3.5 kg)
Dimensions
LxWxH
10.8 in x 4.1 in x 5.5 in
27.4 cm x 10.5 cm x 13.9 cm
Operating
Temperature
32 to 104 ºF (0 to 40 ºC)
Storage Temperature 5 to 113 ºF (15 to 45 ºC)
Operating Relative
Humidity
0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
International Protection Code IP20
Problem and Possible Cause Solution
The Back-UPS will not turn on
The Back-UPS has not been turned on. Press the POWER button.
The Back-UPS is not connected to AC
power, there is no AC power available at
the wall outlet, or the AC power is
experiencing a brownout or over voltage
condition.
Be sure the power cord is securely connected to
the wall outlet, and AC power is available at the
wall outlet.Where ever applicable, be sure that
the wall outlet is switched on.
The Back-UPS is on, the POWER button illuminates red and the unit emits a constant
tone
The battery is disconnected. Refer to the Connect Equipment on page 1.
Connected equipment loses power
A Back-UPS overload condition has
occurred.
Remove all nonessential equipment connected
to the outlets. Reconnect equipment one at a
time to the Back-UPS.
Charge the battery for 24 hours to make sure it
is fully charged. If the overload condition still
persists, replace the battery.
The Back-UPS battery is completely
discharged.
Connect the Back-UPS to AC power and allow
the battery to recharge for ten hours.
PowerChute software has performed a
shutdown due to a power outage.
This is normal Back-UPS operation.
Connected equipment does not accept
the step-approximated sine waveform
from the Back-UPS.
The output waveform is intended for computers
and peripheral devices. It is not intended for use
with motor driven equipment.
The Back-UPS may require service. Contact Schneider Electric Technical Support.
The POWER button illuminates green and flashes twice every 2 seconds.
The Back-UPS is operating on battery
power.
The Back-UPS is operating normally on battery
power. Save all open files, and shutdown the
computer. When AC power is restored the
battery will recharge.
The POWER button flashes green in rapid succession.
The Back-UPS battery has
approximately two minutes of remaining
runtime.
The battery is near a total discharge state. Save
all open files, and shutdown the computer.
When AC power is restored the battery will
recharge.
The Building Wiring Fault LED illuminates red
The building wiring presents a shock
hazard that must be corrected by a
qualified electrical.
Do not operate the Back-UPS. Call a qualified
electrician to correct the building wiring fault.
The Back-UPS has an inadequate battery runtime
The battery is not fully charged.
The battery is near the end of useful life
and should be replaced.
Leave the Back-UPS connected to AC power
for ten hours while the battery charges to full
capacity.
As a battery ages, the runtime capability
decreases. Contact APC by Schneider Electric at
the Web site www.apc.com, to order
replacement batteries.
USB charging is slow
Charging a device using the UPS's USB
charger is slower than the device's
original USB charger
The amount of power a device draws depends
on its compatibility with the USB Battery
Charging Specification 1.2. Compatible devices
can draw more power than devices that are less
compatible.
USB charging stops and the Power On LED alternately illuminates green-amber
The USB port has detected a short circuit
or has detected a fault.
Disconnect cable and device from the USB port.
USB charging will resume when the POWER
button turns green. Contact SEIT Technical
Support if the POWER button remains green-
amber.
The UPS and outlets are off but the UPS keeps beeping twice every 30 seconds (Quiet
Alarm mode) or keeps beeping once every 4 seconds (Full Alarm mode)
In this situation the voltage is not low
enough to shutdown the UPS but not
high enough to start the UPS and power
the outlets. There is however enough
voltage to charge the UPS.
Use Quick Mute to mute the alarm. The UPS
will return to normal operation once the AC
input
voltage has returned to a normal range