Connect the Battery
Connect the battery connector prior to using the UPS.
Inventory Safety and General Information
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there
is excessive dust or humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for
proper ventilation.
The battery typically lasts for two to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and
frequent short duration discharges will shorten battery life.
Connect the Back-UPS power cable directly into a wall outlet. Do not use surge
protectors or extension cords.
Pull the battery connector handle down. Then push the connector into the UPS.
The battery charges fully during the first 10 hours while the Back-UPS is operating on AC
power.
Do not expect full runtime capability during the initial charge period.
There are no serviceable parts in the Back-UPS. Do not attempt to open or repair the
Back-UPS as this will void the warranty. The battery in this unit is not replaceable. Contact
APC through the Web site www.apc.com, for customer support.
bu001c
Installation and Operation Manual
Back-UPS® BX800CI-RS/BX1100CI-RS
Back-UPS BX800CI-RS/BX1100CI-RS Installation and Operation2
PowerChute® Personal Edition Software
Overview
PowerChute Personal Edition So to access additional power protection and ftware allows you to use your computer
management features of the Back-UPS.
Using PowerChute, you can:
Preserve work in progress during a power outage by putting your computer into Hibernate mode. When the
power returns, the computer will appear exactly as it did before the power outage.
Configure the Back-UPS management features, such as power-saving outlets, shutdown parameters, audible
alarms, and more.
Monitor and view the status of the Back-UPS, including the estimated runtime, power consumption, power
event history, and more.
Available features will vary by Back-UPS model and operating system.
If you choose not to install PowerChute, the Back-UPS will still provide backup power and power protection to
connected equipment. However, you will only be able to configure a limited number of features using the display
interface.
Compatibility
PowerChute is compatible with Windows operating systems only. For a detailed list of supported operating systems,
go to www.apc.com, select Software & Firmware.
For Mac operating systems, we recommend using the native shutdown application (within System Preferences)
which recognizes your battery backup and allows you to configure shutdown of your system during power outages.
To access this application, connect a USB cable from the Back-UPS DATA PORT (POWERCHUTE PORT) to a USB port
on your computer, and see the documentation provided with your computer.
Installation
Connect the Back-UPS to a computer using a USB cable. Plug one end into the P C OWER HUTE PORT on the rear panel
of the Back-UPS and the other into a USB port on your computer.
Insert the PowerChute CD into your computer and follow the on-screen instructions. If your Back-UPS did not come
with a PowerChute CD, download the software from www.apc.com, select Software & Firmware.
Back-UPS BX800CI-RS/BX1100CI-RS Installation and Operation 3
Installation
Connect the Equipment
Operation
Turn On the Back-UPS
Press the POWER ON/OFF button located on the front of the Back-UPS. The On Line LED will illuminate green and a
single short beep will be audible to indicate that the Back-UPS is providing protection for connected equipment.
Battery Connector Connect the battery. Refer to “Connect the Battery” on page 1.
DSL/Modem/FAX/Phone Connect one end of a DSL/Modem/FAX/Phone cable to a telephone wall outlet and the other end to the IN port on
the Back-UPS.
Connect one end of a DSL/Modem/FAX/Phone cable to a modem, FAX machine or telephone and the other end to
the OUT port on the Back-UPS.
Battery Backup +
Surge Protection outlets
These outlets provide battery backup power to connected equipment for a limited period of time during power
outages and voltage fluctuations.
The Battery Backup + Surge Protection outlets provide battery power to connected equipment only when the
Back-UPS is turned on.
Connect critical equipment such as a computer, computer monitor, modem or other data sensitive devices to these
outlets.
Do not connect aquarium equipment, laser printers, paper shredders, sump pumps, or fans to these outlets as the
modified sine wave output of the Back-UPS may cause these devices to experience a decrease in performance.
Do not connect surge protectors or extension cords to these outlets.
AC Power Cable Use this cable to connect the Back-UPS to AC power.
Circuit breaker Use to reset the system after an overload condition has occurred causing the circuit breaker to trip.
USB port To use PowerChute software, connect a USB cable (not supplied) to the PowerChute USB port.
bu043e
bu226d
DSL/Modem/Fax/Phone
Circuit Breaker
Push to Reset
Battery Connector
Battery Backup + Surge Protection
Battery Backup + Surge Protection
PowerChute
USB Port
In
Out
bu226c
DSL/Modem/Fax/Phone
Circuit Breaker
Push to Reset
Battery Connector
Battery Backup + Surge Protection
Battery Backup + Surge Protection
PowerChute
USB Port
In
Out


Product specificaties

Merk: Apc
Categorie: UPS
Model: Back-UPS 800
Kleur van het product: Zwart
Snoerlengte: 1.16 m
Geluidsniveau: 45 dB
LED-indicatoren: Ja
Vormfactor: Tower
Aantal USB 2.0-poorten: 1
Ondersteund aantal accu's/batterijen: 1
Certificering: CE, GOST, REACH
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 480 W
Temperatuur bij opslag: -15 - 40 °C
Frequentie: 50/60 Hz
Luchtvochtigheid bij opslag: 0 - 95 procent
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 9000 m
Modem (RJ-11) poort: 2
Efficientie: 96 procent
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Surge energy rating: 273 J
Aantal AC uitgangen: 4 AC-uitgang(en)
Nominale input voltage: 230 V
Stopcontacttypes: Type F
Golf protectie functies: Fax, Modem, Telephone
Stroom (max.): 3 A
Output power capacity: 0.8 kVA
Ingang operation voltage (min): 150 V
Ingang operation voltage (max): 280 V
Uitgang operation voltage (min): - V
Uitgang operation voltage (max): - V
Typische backup tijd op halve lading: 7.2 min
Typische backup tijd op volledige lading: 0.6 min
Netspanning, in bedrijf: 230 V