Apc Back-UPS 750VA Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Apc Back-UPS 750VA (8 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 96 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/8
Installation and Operation
Back-UPS® BE750G Series
Safety
Specifications
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in contact with fluids, or where there
is excessive dust or humidity.
Connect the Back-UPS power cord directly to a wall outlet. Do not use a surge
protector or an extension cord.
Input
Voltage 120 Vac Nominal
Frequency 50 Hz/60 Hz auto sensing
Brownout Transfers 92 Vrms Typical
Over-voltage Transfer 139 Vrms Typical
Output
UPS Capacity
(5 battery backup outlets) 750 VA, 450 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vrms ± 8% step approximated sine wave
Frequency - On Battery 50 Hz/60 Hz ± 1 Hz
Transfer Time 6 ms Typical, 10 ms maximum
Protection and
Filtering
AC Surge Protection Full time, 354 Joules
Phone/DSL/FAX surge protection Single line (2 wire)
Cable/CAT V/DSS surge protection One coax input/output
Network surge protection 10/100 Base -T ethernet
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
Replacement battery cartridge RBC17
Average Life 3 - 5 years depending on the number of discharge cycles and
environmental temperature
Physical
Net Weight 11 lb (5 kg)
Dimensions
Length x Width x Height 14 in x 7 in x 4 in
36 cm x 18 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
EMC
Compliance
This device complies with part 68 and part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This device must accept any
interference received, including interference that may cause undesired operation.
Back-UPS BE750G Series2
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop! Connect the Battery” label that
covers the outlets. Prior to connecting any equipment to the unit, connect the battery cable to the unused battery
terminal. It is normal for small sparks to be seen when the battery cable is connected to the battery terminal.
Wall Mount Installation
• Horizontal installation, use 2 screws 5.9" (150 mm) apart.
• Vertical installation, use 2 screws 5.5" (140 mm) apart.
• Allow 5/16" (8 mm), of the screw to protrude from the wall.
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected
equipment when the Back-UPS is turned on and
connected to utility power.
Battery backup outlets receive power from the
Back-UPS for a limited period of time when a power
outage, or brownout condition occurs.
Battery backup outlets provide protection from power
surges or spikes.
Connect a computer, monitor and other peripheral devices to the outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the Back-UPS is connected to utility
power, and is switched on or off.
Surge protection outlets provide protection from power surges or spikes.
Connect a printer, scanner or other peripheral devices to the surge protection outlets.
Press the battery compartment cover
release tab located on the rear side of the
unit. Slide the battery cover off.
Connect the battery cable securely
to the battery terminal.
Reinstall the battery compartment
cover. Be sure that the release tab
locks into place.
bu076a
bu077a
bu083a
bu207a
Back-UPS
Ma st er
Enable
Battery Backup + Surge Protection
MASTER
Surge Protection
Controlled By MASTER
Back-UPS BE750G Series 3
Connect Modem/Telephone/DSL/FAX/10/100
Base-T Network Cable
The Back-UPS protects a single line, 2 wire telephone
line, including a Digital Subscriber Line (DSL), a
modem, a 10/100 Base-T ethernet, or a FAX machine
from power surges when connected through the
Back-UPS coaxial connectors.
PowerChute® Personal Edition Software
Overview
PowerChute Personal Edition Software allows you to use your computer to access additional power protection and
management features of the Back-UPS.
Using PowerChute, you can:
• Preserve work in progress during a power outage by putting your computer into Hibernate mode.
When the power returns, the computer will appear exactly as it did before the power outage.
• Configure the Back-UPS management features, such as power-saving outlets, shutdown
parameters, audible alarms, and more.
• Monitor and view the status of the Back-UPS, including the estimated runtime, power
consumption, power event history, and more.
Available features will vary by Back-UPS model and operating system.
If you choose not to install PowerChute, the Back-UPS will still provide backup power and power protection to
connected equipment. However, you will only be able to configure a limited number of features using the display
interface.
Compatibility
PowerChute is compatible with Windows operating systems only. For a detailed list of supported operating
systems, go to www.apc.com, select Software & Firmware.
For Mac operating systems, we recommend using the native shutdown application (within System Preferences)
which recognizes your battery backup and allows you to configure shutdown of your system during power outages.
To access this application, connect a USB cable from the Back-UPS DATA PORT (POWERCHUTE PORT) to a USB
port on your computer, and see the documentation provided with your computer.
Installation
Connect the Back-UPS to a computer using a USB cable. Plug one end into the P COWER HUTE PORT on the rear
panel of the Back-UPS and the other into a USB port on your computer.
Insert the PowerChute CD into your computer and follow the on-screen instructions. If your Back-UPS did not
come with a PowerChute CD, download the software from www.apc.com, select Software & Firmware.
bu209a
CAUTION-Ref er to bottom
of unit for safety markings.
Building
Wiring Fault
PowerChute
USB Port
Circuit Breaker
Push to Reset
Cable In Cable Out
Out
In
Network/DSL/Modem/FAX
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Back-UPS 750VA |
Kleur van het product: | Zwart |
Gewicht: | 4700 g |
Breedte: | 180 mm |
Diepte: | 343 mm |
Hoogte: | 88 mm |
Snoerlengte: | 1.83 m |
Geluidsniveau: | 45 dB |
LED-indicatoren: | Batterijvervanging |
Vormfactor: | Compact |
Aantal Ethernet LAN (RJ-45)-poorten: | 3 |
Certificering: | FCC, NOM, UL |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 450 W |
Accu/Batterij oplaadtijd: | 16 uur |
Temperatuur bij opslag: | -15 - 45 °C |
Frequentie: | 50/60 Hz |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Netwerkfuncties: | Fast Ethernet |
Filtratie: | Ja |
Hoogte, in bedrijf: | 0 - 3000 m |
Hoogte bij opslag: | 0 - 15000 m |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Type batterij: | RBC17 |
Surge energy rating: | 354 J |
Aantal AC uitgangen: | 10 AC-uitgang(en) |
Nominale input voltage: | 120 V |
Stopcontacttypes: | NEMA 5–15R |
Golf protectie functies: | A/V, Coax, Fax, Modem, Network, Telephone |
Output power capacity: | 0.75 kVA |
Ingang operation voltage (min): | - V |
Ingang operation voltage (max): | - V |
Uitgang operation voltage (min): | - V |
Uitgang operation voltage (max): | - V |
Netspanning, in bedrijf: | 120 V |
Spanningsbeveiliging: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Back-UPS 750VA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
2 December 2024
2 December 2024
2 December 2024
2 December 2024
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
18 November 2024
17 November 2024
17 November 2024
17 November 2024