T3MK75F16
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with TM3 Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8 - Fuse Protected Access Power Controllers
- One (1) PD8UL - Fuse Protected Power Distribution Module
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
(Not evaluated by UL)
T3MK77F16
16 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove3 enclosure with TM3 Altronix/Mercury backplane
- Two (2) eFlow104NB - Power Supply/Chargers
- Two (2) ACM8 - Fuse Protected Access Power Controllers
- Two (2) PD8UL - Fuse Protected Power Distribution Modules
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
(Not evaluated by UL)
T3MK75F16D
16 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove3 enclosure with TM3 Altronix/Mercury backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8CB - PTC Protected Access Power Controllers
- One (1) PD8ULCB - PTC Protected Power Distribution Module
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
(Not evaluated by UL)
T3MK77F16D
16 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove3 enclosure with TM3 Altronix/Mercury backplane
- Two (2) eFlow104NB - Power Supply/Chargers
- Two (2) ACM8CB - PTC Protected Access Power Controllers
- Two (2) PD8ULCB - PTC Protected Power Distribution Modules
- One (1) Rocker Switch Bracket with Two (2) Rocker Switches
(Not evaluated by UL)
Access & Power Integration
Rev. T3MK071818
Installing Company: Service Rep. Name: _____________________ __________________________________________
Address: Phone #: ________________________________________________________ _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T3MK Kits
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove3M3 enclosure/backplane with factory installed Altronix power
supply/charger(s) and sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors
in a single enclosure.
Configuration Chart:
Altronix
Model Number
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC Output Voltage
Maximum
Supply
Current for
Main and Aux.
Outputs on Power
Supply board
and ACM8(CB)
Access Power
Controller’s
outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Current Per
ACM8(CB) Output (A)
ACM8(CB) Board
Input Fuse Rating
ACM8 Board
Output Fuse Rating
ACM8CB Board
Output PTC Rating
PD8UL Board
Output Fuse Rating
PD8ULCB Board
Output Fuse Rating
Power Supply 1 Power Supply 2
[DC] [Aux] [DC] [Aux]
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
T3MK75F16 86.3A/250V
5A/250V
15A/
32V
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V –3.5A/
250V –
T3MK75F16D 86.3A/250V
5A/250V
15A/
32V
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A 16 2.5 10A/
250V – 2A – 2.5A
T3MK77F16 96.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4 24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V –3.5A/
250V –
T3MK77F16D 96.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4 24VDC @ 9.2A 16 2.5 10A/
250V – 2A – 2.5A
Hardware and Accessories:
• Two (2) tamper switches (Altronix Model TS112 or equivalent).
• Cam lock.
• Battery leads.
Mechanical:
• 16 Gauge enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws
in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install
the three fasteners. Place the enclosure’s upper keyholes over the three upper screws.
Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switches (Altronix Model TS112 or equivalent) in desired location,
opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2”
from the right side . Connect tamper switch wiring to the Access Control Panel input (Fig. 1, pg. 2)
or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Mount Mercury boards to backplane, refer to pg. 3, 4.
5. Refer to the for eFlow104NB, eFlow102NB eFlow Power Supply/Charger Installation Guide
and corresponding for PD8UL(CB) and ACM8(CB) for Sub-Assembly Installation Guides
further installation instructions.
6. Position Mercury access controller module over corresponding standoffs and depress onto
snap on standoffs (Fig. 2-3, pg. 3-4).
7. Mount backplane to enclosure with hardware.
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
T3MK Kits - 3 -
T3MK75F16 and T3MK75F16D: Configuration of Mercury Boards:
1. Fasten snap on standoffs onto metal pems configuration (A) (B) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, MR52, MR16IN, MR16OUT A
EP2500, MUX8 B
EP1501, MR51e C
MR52 D
Altronix
eFlow104NB
Altronix
eFlow102NB
Altronix
ACM8(CB)
Altronix
ACM8(CB)
Altronix PD8UL(CB)
D
B
B
A
A
A
A
A
A
A
A
C
RSB2 Bracket
Rocker Switch
Fig. 2
Snap On
Standoff
Mercury Board
Backplane
Pem
Fig. 2a


Product specificaties

Merk: Altronix
Categorie: Niet gecategoriseerd
Model: T3MK75F16

Heb je hulp nodig?

Als je hulp nodig hebt met Altronix T3MK75F16 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Altronix

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd