Access & Power Integration
Rev. TMK051217
Installing Company: Service Rep. Name: _____________________ __________________________________________
Address: Phone #: ________________________________________________________ _________________________
All registered trademarks are property of their respective owners. More than just power.β„’
Installation Guide
T2MK3F4
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM4 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK3F4Q
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM4 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK3F8
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) ACM8 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK3F8Q
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow6NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM8 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK7F8
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) ACM8 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK7F8Q
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- (1) eFlow104NB - Power Supply/Charger
- (1) LINQ2 - Network Communications Module
- (1) ACM8 - Fused Access Power Controller
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK75F16
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane and TMV2 door backplane
- (1) eFlow104NB and (1) eFlow102NB - Power Supply/Chargers
- (2) ACM8 - Fused Access Power Controllers
- (1) PD16W - Power Distribution Module
T2MK75F16Q
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane and TMV2 door backplane
- (1) eFlow104NB and (1) eFlow102NB - Power Supply/Chargers
- (1) LINQ2 - Network Communications Module
- (2) ACM8 - Fused Access Power Controllers
- (1) PD16W - Power Distribution Module
T2MK77F16
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane and TMV2 door backplane
- (2) eFlow104NB - Power Supply/Chargers
- (2) ACM8 - Fused Access Power Controllers
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
T2MK77F16Q
Fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane and TMV2 door backplane
- (2) eFlow104NB - Power Supply/Chargers
- (1) LINQ2 - Network Communications Module
- (2) ACM8 - Fused Access Power Controllers
- (1) VR6 - Voltage Regulator
- (1) PDS8 - Dual Input Power Distribution Module
4 Door Kits with Fused Outputs:
8 Door Kits with Fused Outputs:
16 Door Kits with Fused Outputs:
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T2MK Kits
Overview:
Altronix Trove Mercury kits are pre-assembled and consist of Trove2M2 enclosure/backplane with factory installed Altronix power supply/charger(s) and
sub-assemblies. These kits also accommodate various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
Configuration Chart:
Altronix
Model Number
Networkable
120VAC 60Hz
Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC Output
Voltage
Maximum Supply
Current for Main
and Aux. Outputs
on Power Supply
board and ACM4/
ACM8 Access Power
Controller’s outputs
Fail-Safe/Fail-Secure or
Dry Form β€œC” Outputs
Current Per
ACM4/ACM8 Output (A)
ACM4/ACM8 Board
Input Fuse Rating
ACM4/ACM8 Board
Output Fuse Rating
PDS8 Board
Input Fuse Rating
PDS8 Board
Output Fuse Rating
PD8UL/PD16W Board
Output Fuse Rating
Power
Supply 1
Power
Supply 2
[DC] [Aux] [DC] [Aux]
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
Output Range
(VDC)
T2MK3F4 – 3.5 5A/
250V
10A/
32V
20.19-
26.4
20.19-
26.4 – – 4 2.524VDC @ 5.8A 10A/
250V
3A/
250V
10A/
250V
3A/
250V –
T2MK3F4Q P3.5 5A/
250V
10A/
32V
20.19-
26.4
20.19-
26.4 – – 4 2.524VDC @ 5.8A 10A/
250V
3A/
250V
10A/
250V
3A/
250V –
T2MK3F8 – 3.5 5A/
250V
10A/
32V
20.19-
26.4
20.19-
26.4 – – 8 2.524VDC @ 5.8A 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
T2MK3F8Q P3.5 5A/
250V
10A/
32V
20.19-
26.4
20.19-
26.4 – – 8 2.524VDC @ 5.8A 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
T2MK7F8 – 4.5 6.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4 – – 8 2.524VDC @ 9.2A 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
T2MK7F8Q P4.5 6.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4 – – 8 2.524VDC @ 9.2A 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
T2MK75F16 – 8
6.3A/
250V 15A/
32V
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V – – 3.5A/
250V
5A/
250V
T2MK75F16Q P8
6.3A/
250V 15A/
32V
20.17-
26.4
20.28-
26.4
9.7-
13.2
10.03-
13.2
12VDC @ 9.3A
24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V – – 3.5A/
250V
5A/
250V
T2MK77F16 – 9 6.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4 24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
T2MK77F16Q P96.3A/
250V
15A/
32V
20.17-
26.4
20.28-
26.4
20.17-
26.4
20.28-
26.4 24VDC @ 9.2A 16 2.5 10A/
250V
2.5A/
250V
10A/
250V
3A/
250V –
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane(s) from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners
and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper
screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes
and install the three fasteners. Place the enclosure’s upper keyholes over the three upper screws. Install the three
lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite
hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2” from the right side
(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed
reporting device. To activate alarm signal open the door of the enclosure.
4. Refer to the for eFlow6NB, eFlow102NB, eFlow104NB and eFlow Power Supply/Charger Installation Guide
Sub-Assembly Installation Guide for the following models: ACM4, ACM8, LINQ2, PDS8, VR6 for further
installation instructions.
5. Fasten snap on standoffs onto metal pems configuration of backplane depending on the Mercury access controller
.(Fig. 2-5, pg. 3-6)
6. Position Mercury access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2-5, pg. 3-6).
7. Mount backplane to enclosure with hardware.
Fig. 1
Tamper Switch
(provided)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
T2MK Kits - 3 -
T2MK3F4, T2MK3F4Q, T2MK3F8, T2MK3F8Q: Configuration of Mercury Boards:
1. Fasten snap on standoffs onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 2, pg. 3).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 2a, pg. 3).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
EP1502, MR52, MR16IN, MR16OUT A
EP2500, MUX8 B
EP1501, MR51e C
MR50 D
Fig. 2
OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8
NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM
IN GND IN GND IN GND IN GNDIN GND IN GND IN GND IN GND
1 2 3 4 5 6 7 8
INPUT
TRIGGER
10A 250V
+INP- T + RET-NO C NC
FACP INT ERFACEPower Control
- + - +
F1 F2 F3 F4 F5 F6 F7 F8
MAIN
T RG
FACP
1 2 3 4
ON
1 2 3 4
ON
Altronix ACM8 (T2MK3F8(Q))
Altronix LINQ2 Module (T2MK3F4Q, T2MK3F8Q)
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1 EOL NO GND
SUPERVISED RESET
+AUX-
- BAT + - D C +
L G N
OFF - 24V
ON - 12V
ON
Altronix
eFlow6NB
T RG
T RIGGER
INPUT
ACM4
ACCESS POWER
CONT ROLLER
LED1 LED2 LED3 LED4
MAIN
OUT P UT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUT P UT 2 OUT PUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUT P UT 4
-- +
CO N T RO L
-- +
PO WER
+INP - T +RET -
INT ERFAC E
NO C NC
FAC P
Altronix
ACM4
(T2MK3F4(Q))
+ INP 1 --
DM1 + OFF
IN1
IN2
Ou t1
<1 off 2>
DM1 +
DM2 +
DM2 +
Co mm on (--- )
Co mm on (--- )
+ INP 2 --
IN2 Fuse
IN1 Fuse
Comm on P owe r Out put s (NEG)
N
P
OU T 1 OU T 2 OU T 3 OU T 4 OU T 5 OU T 6 OU T 7 OU T 8
1 2 3 4 5 6 7 8
10
10
3
33 3 3 3 3 3
Ou t2<
1 off 2 >
Ou t3<1 off 2>
Ou t4
<1 off 2>
Ou t5
<1 off 2>
Ou t6
<1 off 2>
Ou t7
<1 off 2>
Ou t8
<1 off 2>
Altronix PDS8
Altronix VR6 mounted under PDS8
B
B
AB
CC
CC
C
D
D
B
A
A
A
Snap On
Standoff
Mercury Board
Backplane
Pem
Fig. 2a


Product specificaties

Merk: Altronix
Categorie: Niet gecategoriseerd
Model: T2MK77F16

Heb je hulp nodig?

Als je hulp nodig hebt met Altronix T2MK77F16 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Altronix

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd