Power over the Ethernet
PoE Managed Midspan Solution for
Standard Network Infrastructure
Installation Guide
Models Include:
NetWay8M NetWay16M
- Eight (8) Port PoE Midspan Injector - Sixteen (16) Port PoE Midspan Injector
DOC#: NETM
Rev. 052110 More than just power.™
- 2 - NetWay8M/ NetWay16M
Overview:
Altronix NetWay8M/NetWay16M Managed Midspans provide power and pass data for PoE compliant cameras/edge devic-
es. Cameras/edge devices may be located up to 100m (328 ft.) from the NetWay unit. A NetWayXT repeater module can be
utilized to extend the distance an additional 100m (328 ft.) for a total range of up to 200m (656 ft.). A maximum range of
600m (1968 ft.) is possible using multiple repeaters, based on camera/device port requirement. NetWay Managed Midspans
are capable of supporting non-PoE compliant fixed and PTZ IP cameras utilizing NetWay1512 or NetWay3012 adapters.
NetWayM Specifications:
NetWay8M:
•Eight(8)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,3amp(NetWay8M).
NetWay16M:
•Sixteen(16)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,4.9amp(NetWay16M).
Common Specifications:
Agency Listings:
•UL/CULListedforInformationTechnologyEquipment
 (UL60950-1).
• ULListedforAccessControlSystems(UL294).
• CEapproved.
Power:
•UnitsuppliesPoEoutputvoltage(55V),andupto30Wmax.
full power per port. Total power: NetWay8M - 150W,
NetWay16M - 300W.
•IEEE802.3afandIEEE802.3atcompliant(PoEPlus).
•Alloutputcircuitsarepowerlimited.
•Shortcircuitprotection.
Functions:
•ProgrammblePoEshutdownforeachport.Utilizedto
reset cameras/edge devices
(see Technical Specifications pg. 5).
• PoEmanualshutdown(ForUL60950-1applications
only) . (see Technical Specifications pg. 5)
•Autodetectionandprotectionoflegacy
non-PoE cameras/edge devices.
Features:
•LANorlaptopconnectionenablesprogrammingof
PoE shutdown and port monitoring.
•Userinterface(Fig. 5, pg. 7).
•Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset (switch).
•IndividualportstatusLEDs.
•IEC320-3-wiregroundedlinecord(detachable).
•Unitcanberackorshelfmounted.
•1UrackmountchassisforuseinstandardEIA19”rack.
Accessories:
NetWay1512:
•15Wadapterfornon-PoEcompliantIPcameras.
 (ForUL60950-1applicationsonly).
NetWay3012:
•25Wadapterfornon-PoEcompliantIP
fixed or PTZ cameras.
(ForUL60950-1applicationsonly).
NetWayXT:
•PoErepeatermoduleextendsrange100m(328ft.)
 (ForUL60950-1applicationsonly).
Installation Instructions:
WiringmethodsshallbeinaccordancewiththeNationalElectricalCode(ANSI/NFPA70),localcodes,andtheauthoritieshaving
jurisdiction.
NetWayM is not intended to be connected to outside plant leads. These products are for indoor use only and must be
installed within the protected premises.
1. NetWayM .Attachmountingbracketsto unitforrackorwallmountinstallation(Figs. 8 or 9, pg. 10)
Affix rubber pads to for shelf installation NetWayM (Fig. 10, pg. 10).
2. Securetheunitinarackorplaceunitonashelfasdesired.
Note:Thefollowingfactorsshouldbetakenintoconsiderationwheninstallingtheserackmountunits:
 a.Theunitistobeinstalledinaspacewherethemaximumambienttemperaturedoesnotexceed104ºF(40ºC).
 b.Takecaretoinsurethereissufficientairflowaroundtheunitandthatobstructionsdonotimpedeit.
 c.Whenmountingunitsinrack,takecaretoavoidunevenloadingwhichcancauseahazardouscondition.
3. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig. 1g, pg. 3).
4. PlugthegroundedAClinecord(included)intotheIEC320connectoroftheNetWayMunit
(Fig. 1h, pg. 3).Plugunitintoareliableearthgroundedsocket.Whenusingmultipleunitsthesumoftheindividual
 nameplateratingsshouldnotexceedthesupplycircuitrating.DonotConnectToAReceptacleControlledByA
 Switch.
5. Connectstructuredcablesfromportmarked[IN]onNetWayMtothecorrespondinginputsofanethernetswitchor
video server .(Fig. 1b, pg. 3, Fig. 4, pg. 5)
Note:AllcablingandwiremustbeULListedand/orRecognizedwiresuitablefortheirapplication.
6. Connectstructuredcablesfromportmarked[OUT]onNetWayMtoPoEcompliantcamera/edge
devices . (Fig. 1a, pg. 3, Fig. 4, pg. 5)
Note: ForUL294applications,theproductsaretobetestedaspartofacompleteAccessControlSystemandin
 accordancewithULListedAccessControlDevices.
NetWay8M/ NetWay16M - 3 -
Fig. 1
1a OUT1-8(NetWay8M),OUT1-16(NetWay16M):StructuredcabletoPoEcompliantcameras/edgedevices.
1b IN1-8(NetWay8M),IN1-16(NetWay16M):Structuredcabletoethernetswitchorvideoserver.
1c LED(s)1-8(NetWay8M),1-16(NetWay16M):PortstatusLEDs.
1d Reset:Restoresunittofactorysettings.
1e +---,PoEShutdown:Lowvoltagetriggerinput(see Technical Specifications pg. 5).
1f Ethernet:LANorlaptopconnectionenablesNetWayMprogrammingandstatusmonitoring.
AC POWER
NetWay8M & Net y16M - Rear PanelWa
NetWay8M - Front Panel
NetWay16M - Front Panel
+ PoE --
SHUTDOWN
+ PoE --
SHUTDOWN
1a 1b 1c 1d 1e 1f
1g 1h
Note: AllinterconnecteddevicesmustbeULListed.
7. UponcompletionofwiringsetilluminatedmasterpowerdisconnectcircuitbreakertotheRESET(ON)
position .(Fig. 1g, pg. 3)
8. PortstatusLEDsontheNetWayMwillinitializewhenPoEdevicesareconnectedasfollows:
 - LEDwillilluminatewhendevicesareIEEE802.3afcompliant.
 - LEDwillblinkonceandilluminatewhendevicesareIEEE802.3atcompliant(PoEPlus).
9. To utilize the PoE shutdown feature it is necessary to do the following:
a. Connect a device that will provide a low voltage trigger input (see Technical Specifications pg. 5) to terminals
  marked[+---,PoEShutdown]ontheNetWayM(Fig. 1e, pg. 2). When voltage is applied, the PoE shutdown
  enabledPoEport(s)willdroptozerovolts.Removingthelowvoltagetriggerinputatthe[+---,PoEshutdown]
terminals will allow the PoE port(s) to operate normally and supply power to PoE compliant devices. Power will
  resetinapproximately4seconds.AlthoughthereisnooutputvoltagetopowerPoEdevicesduringshutdown,data
signals may still be present on the data pair lines of the structured cable.
b. Individual ports must be programmed utilizing the user interface .(see User Interface and Programming, pgs. 6-9)
Port Status and LED Flash Codes:
Port Status Flash Codes Description
AllPortsOff SequentialLEDPortScan No devices connected
PortOff OFF LEDOFF
PortOn ON LEDON
Class4detectionPort Blinks2times Enables power to PoE devices.
Non-compliantDevice 2Hz Will prevent port from turning on.
PortOverloadFault 5Hz Will prevent port from turning on.
4PortOverloadGrouped 5Hz 4LEDs
Will prevent ports from turning on.
8PortOverloadGrouped 5Hz LED’s1-8PowerSupplyOverloadforports1-8.
LED’s9-16PowerSupplyOverloadforports9-16.


Product specificaties

Merk: Altronix
Categorie: Netwerkkaart/adapter
Model: NETWAY16M
Gewicht: 3628 g
LED-indicatoren: Ja
Stroom: 4.9 A
Aantal Ethernet LAN (RJ-45)-poorten: 16
Certificering: UL 60950-1, UL294, CUL UL 60950-1, CE, RoHS
Ingangsspanning: 115 V
Bekabelingstechnologie: CAT5
Frequentie: 60 Hz
Power over Ethernet (PoE): Ja
Afmetingen (B x D x H): 486 x 216 x 42 mm
Stroom via Ethernet (PoE): - V

Heb je hulp nodig?

Als je hulp nodig hebt met Altronix NETWAY16M stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Netwerkkaart/adapter Altronix

Handleiding Netwerkkaart/adapter

Nieuwste handleidingen voor Netwerkkaart/adapter