4ms Row Power 25 Handleiding

4ms Niet gecategoriseerd Row Power 25

Lees hieronder de 📖 handleiding in het Nederlandse voor 4ms Row Power 25 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Row Power 25
4ms Company
Eurorack Power Module
User Manual 1.0 – Sept. 24, 2019
!
The Row Power 25 is a power supply module for the Eurorack modular system. It
requires a barrel-style power brick (15V – 20V DC) and supplies power to modules
via flying bus cables, direction connection, and/or bus boards using the single
standard 16-pin Eurorack header on the back. For custom power systems, the
Row Power 25 has a set of easily soldered holes for using large gauge wire or
MTA156 connectors to connect to distribution bus boards.!
Multiple Row Power modules can be powered from a single power brick by
daisy-chaining with an inexpensive barrel cable. The Row Power 25 can also be
daisy-chained to 4ms Company’s Pod enclosures.!
Maximum and recommended power output:
+12V: 1.4A maximum, 1.0A recommended!
-12V: 0.8A maximum, 0.5A recommended!
+5V: 1.0A maximum, 0.8A recommended!
Maximum power output can be expected under normal operating conditions.
Recommended power output is guaranteed under extreme temperature and limited airflow
conditions.
Power Brick:
Available wherever Row Power modules are sold.!
You may use your own power brick if it meets the following:!
15VDC to 20VDC!
Minimum 30W output power!
Positive center 2.1mm barrel plug!
Low-noise output!
Features:
Two identical barrel power jacks at top and bottom for daisy-chaining (either
jack can be used for power input or chaining)!
• !On/off switch
• !LED indicates +/-12V rails are functioning
• !25.6mm (1.01”) deep with power cable attached
• !22.0mm (0.87”) with no power cable (when using solder points)
• #4HP
Page of  1 4
Installation
The Row Power 25 can be used with flying bus cables, multi-
power cables, bus boards and other passive distribution
systems.!
Flying Bus Cables!
A flying bus cable has a female connector on one end. Simply
plug the female connector into the male pins on the back of
the Row Power 25. The notch on the male pin connector will
prevent you from plugging a standard cable in backwards, but
it’s always good practice to verify he red stripe on the cable t
is orientated towards the bottom of the module.!
If you have more than one flying bus cable, you can safely
daisy-chain them together. You also can daisy-chain a bus
board or bus stick to the end of the flying bus cable, or vice-
versa. To insure the lowest noise in a Eurorack system, always
use the shortest power cables available and the least number
of connectors.
Direct Connection
You can directly connect any Eurorack module to the Row Power 25. Simply plug the 16-pin cable to
the Row Power 25s 16-pin header. Verify the red stripe is down on both ends of the cable.!
Multi-Power Connectors
These type of cables are similar to flying bus cables, but have multiple female connectors instead of
male connectors. They will only be a good solution if you intend to power three or less modules which
all have the same time of power header (10-pin or 16-pin). Simply plug the 16-pin connector on the
end of the multi-power connector to the Row Power 25 and then plug the female connectors directly
to your modules. The multi-power connectors sold by 4ms can connect to up to three modules and
they cannot be daisy-chained since they have only female connectors. For powering more than three
modules, or for powering some modules with 10-pin headers and some modules with 16-pin headers,
we recommend using flying bus cables.#
Page of  2 4
Bus Board (4ms Bus Stick or other passive distribution board)
Any passive power distribution board can be used with the Row Power 25. If the bus board connects
to the power supply with a standard 16-pin Eurorack power cable, then simply use the male pin power
connector on the back of the Row Power 25 to connect to the bus board. Verify the red stripe is
pointed down on both ends of the cable. An example using the 4ms Bus Stick is shown below.!
The Bus Stick can be secured to the case using the adhesive pads on the back. Make sure the surface
is clean and apply pressure for 20 seconds. It’s safe to daisy-chain a flying bus cable or another Bus
Stick, but to insure the lowest noise system, use as few connectors as possible.!
Solder connectors
The Row Power 25 has a set of four holes for +12V, -12V, +5V, and ground. The holes are
0.082” (2.1mm) in diameter and are spaced 0.156” (3.96mm). They fit the Molex MTA156 connector
(example: Molex PN: 5273-04A or 09652048). They also will fit 14 AWG wire.!
These connectors are provided for advanced users with sufficient knowledge of soldering and power
systems. They can be used with a custom or specialized low-noise bus board system. While 4ms
Company will warranty and support the internal circuitry of the Row Power 25, we do not offer
support for 3rd party or DIY bus boards or distribution systems.!
#
Page of  3 4


Product specificaties

Merk: 4ms
Categorie: Niet gecategoriseerd
Model: Row Power 25

Heb je hulp nodig?

Als je hulp nodig hebt met 4ms Row Power 25 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd 4ms

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd