Winix L200 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Winix L200 (2 pagina's) in de categorie Luchtbevochtigers. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
1
4
2
5
3
6
PACKAGE CONTENTS
Water Tank
Nozzle
Water Tank Cap
UV+ SYSTEM
User
Manual
User Manual
L200 / L2 01Model Na me:
Use & Care
Guide:
Ultrasonic Humidifier
The Product warrranty is printed on the back of this guide.
This Product is manufactured for use only i n USA / C A .
This Product is sui table for 120 V only .
Demineralization
Capsules (2)
Pre-Soaked
Aroma Pads (2)
Unit
Handle
Control
Display
Mist Tube
Aroma Pad
Tray
Power Cord
LightCel™ Cover
Guide Bracket
Silencer
Water Valve
Air Outlet
WHERE TO USE
MODEL PART DIAGRAM
12~18 in 12~18 in
Position the humidifier at least 12 in / 30 cm away from walls and
appliances to prevent them from getting wet.
Place the humidifier on a table or desk. Do not place it directly on the
floor or carpet.
DO NOT place the unit against walls or objects or in areas with poor
air circulation. Doing so may result in improper readings produced
by the built-in humidity sensor.
If used in a closed (sealed) room without proper ventilation and no
heat exchange with outside air, water collection can occur when
the humidified air touches the cold surface. In such cases, it is
recommended to use in a lower mist level.
01. Power Button
Plug unit into a 120-volt AC electrical outlet.
Press the power button to turn unit on.
If there is no water inside, the power button does
not work.
02. Warm Mist Setting
To change the mist temperature from cool to warm
mist, press the warm mist button.
Warm humidification mode is always OFF and is
heated only when the user operates the button.
03. Night Mood Light
Press the Night Mood Light Display Button once
to turn on the Night Mood Light. The light at the
bottom of the water tank will turn on, illuminating
the tank.
The brightness of the light should be switched
OFF > 100% > 50% > 20% > OFF > Display light Off.
04. Programable Auto-Off Timer
Keep pressing the programmable timer button until
the desired timer setting is lit on the display.
The programable timer button will cycle through the
following settings: 0 hours, 2 hours, 4 hours, 8 hours,
and 12 hours. To cancel the timer at any time, press
the timer button until 0 hours is shown on the display.
CONTROL PANEL
Capacity
2 Gallons - 7.5 Liters
LightCel™ Technology
UV-C LED antibacterial.
Runtime: Max 120 Hours
Based on the natural humidity level in your home, the
temperature of water you use, and the mist level setting
you choose, you may experience longer or shorter
runtimes.
Adjustable Mist Level
Mist adjusts from the lowest output to highest ouput.
The corresponding mist level will be lit on the LED
indicator.
Each press will increase by one. Once you reach level 5,
it will repeat at level 1.
360 Rotating Mist Nozzle°
Rotate the mist nozzle to adjust the mist output direction.
Whisper-Quiet Operation
Quiet operation allows you to sleep easily in a
comfortable and quiet environment.
Night Mood Light
A useful light feature is included with the option of an
independent Night Mood Light and control light display.
Auto Shut Off Protection
When the tank is empty, the unit will shut off
automatically.
Demineralization Capsules
The Winix demineralization capsule will help reduce the
potential for white dust; a deposit of minerals left behind
from using hard water in your humidifier.
Installation Instructions:
1. Open the Water Tank Cap and fill the tank with water up
to 'max'.
2. Remove demineralization capsule from the package.
3. Put the capsule into the tank and wait for 10 minutes.
4. Demineralization capsule cannot be reused. If you
want to place an order of our demineralization capsule,
please visit www.winixamerica.com.
Pre-Soaked Aroma Pads & Aroma Pad Tray
Includes 2 Pre-Soaked Aroma Pads. Use your favorite
essential oil to deliver aroma into the air.
Installation Instructions:
1. Turn off the humidifier.
2. Push the Oil Tray at the back of the base and pull it out.
3. Tear the pouch at the notch to expose pad, insert pad
into the Aroma Tray.
4. Enjoy the refreshing aroma! The scent lasts up to 48
hours (2 full days).
CAUTION
1) Contact with exposed pad may cause eye irritation. In
case of contact with eyes, flush with water immediately.
If eye irritation persists, consult with a doctor.
2) If you want to remove the aroma pad or if the humidifier
has not been operating for a long time, clean and dry
the tray and put it back in place.
3) Never put the aroma pad in the water tank.
MAINTENANCE AND CLEANINGULTRASONIC WARM & COOL MIST HUMIDIFICATION
Read all instructions before installation and use
Always place humidifier on a firm, flat surface.
A waterproof mat or pad is recommended for under
the humidifier. A finished floor may be damaged by
water or moisture exposure.
Do not reach for a unit that has fallen into water.
Unplug it immediately.
Always unplug the unit from the electrical outlet
immediately after using and before cleaning.
Do not place or store the unit where it can fall or be
pulled into a tub or sink.
Wash the nozzle, cover separately, and let tank dry in
the shade
Clean tank at least once or twice a week using
clean water.
Naturally occurring stains inside the tank can be
cleaned using a soft cloth.
Do not use chemicals such as bleach, abrasive, etc.
to clean.
Cleaning the ultrasonic transducer
Clean the ultrasonic module of
the humidifier at least once or
twice a week.
Tilt it in the direction of the air
hinge when disposing of
the water in the main body.
Do not allow water into this
opening (air outlet).
Never touch the transducer/ultrasonic membrane
with your fingers; the natural oil and cosmetics
in the skin can damage the surface.
Never clean the ultrasonic membrane by scraping
with a hard object. Scratching the surface of the
vibrator with a sharp object may cause the Mist
Output to weaken or cause failure.
Never submerge the base in water or any other liquid.
In general, if the user touches the transducer/
ultrasonic membrane with their fingers, the natural
oil and cosmetics on the skin can damage the
surface, resulting in irregular mist output.
In order to have the unit run properly after this
occurs, you need to:
1. Wash the water tank and the base 2 ~ 3 times and
then restart the unit. In case the unit is not washed,
the unit will operate normally after running for
30 min ~ 1 hour on continuous mode.
2. If the water is not enough, the mist may not be
generated properly. (This may be a defect in the air
hinge or water valve).
There should be at least
30 mm of water in the base after removing the
water tanks.
Guide bracket silencer
Press down on the hook and lift it up.
It is best to wash off with clean, running water.
Dry and refit.
Deep cleaning (with vinegar)
Before and after storing the humidifier for a long
period of time, be sure to dry the Mist Output
completely and wipe clean.
Clean the tank, reservoir, tank cap, and transducer/
ultrasonic membrane with a 10:1 ratio mixture of
water and white vinegar.
Fill the tank with diluted vinegar water to the
maximum level.
Put roughly 400 mL of mixed water into the main
body.
Fill the water tank and main body with water and
leave for 30 to 60 minutes.
Pour out mixed water and rinse with clean tap water
2 ~ 3 times.
Dry the parts in a well-shaded place.
Please reassemble the dried product.
INITIAL OPERATION
CAUTION: Before filling the tank with water, turn the power off and unplug the unit from the outlet.
NOTE: Always use 2 hands to carry the water tank.
1. Remove the water tank cap to fill the tank.
The convenient top-fill tank can be filled with a
pitcher or at the faucet.
2. Lift the water tank from the base by using the
handle located on the back of the unit.
3. Fill the tank with clean, room temperture water
until the water level reaches the MAX fill mark.
4. The water tank holds a maximum of 7.5 Liters.
Water level is visible from outside.
5. Plug in to outlet and turn appliance on. Always add
water to unit before connecting to power to avoid
burning the unit.
6. Always operate the humidifier with the tank
cover seated on the tank. Refill the water tank to
continue using the humidifier.
Replacing Aroma Pads
Pre-Soaked Aroma Pads last 48 hours each.
There are two Pre-Soaked Aroma Pad scents:
1 lavender and 1 eucalyptus.
Please don't put any other materials other than
Aroma Pads.
05. Programmable Humidistat
The default humidistat setting is CO (continuous).
The programmable humidistat can be set in 5%
increments, from 40% to 60% humidity.
Manual humidity is set in 40% > 45% > 50% > 55% >
60% > CO order.
NOTE: When the set humidity level is reached, the
humidifier will cycle off until the humidity in the
room drops 5% below the set humidity level, then
will cycle on until the set humidity level is reached
again.
06. Adjustable Mist Level
Mist adjusts from the lowest output to the highest
output.
The corresponding mist level will be lit on the
display. Each press will increase by one.
Once you reach level 5, it will repeat at level 1.
07. LightCel™ (UV+)
Displays the operation status of the UV-C LED that
sterilizes the flow path of the reservoir.
Power of the product is activated and turned off
when no water is detected.
NOTE: LightCel™ Technology Removes bacteria*
present in water, Ensuring a safe and sanitized mist
for you and your family.
(*Based on independent laboratory test conducted
on Escherichia coil, Staphylococcus aureus,
Salmonella typhimurium, Klebsiella pneumoniae)
08. Warm Light
If you select warm humidification, it turns on.
09. Timer/Display Light
When a time reservation is set, it turns on and
displays the time on the display.
10. Empty Tank Alarm
If there is not enough water, the unit will stop and
the red LED indicator will continue to blink at the
same time.
11. Mist Level Indicator
Displays the humidity level and goes up one step
each time the humidity level button is pressed.
07
08 11
09 10
01
02
03
04
05
06
LUNA2.0_EN.indd 1
LUNA2.0_EN.indd 1
LUNA2.0_EN.indd 1
LUNA2.0_EN.indd 1LUNA2.0_EN.indd 1 2020-10-22  5:54:09
2020-10-22  5:54:09
2020-10-22  5:54:09
2020-10-22  5:54:092020-10-22  5:54:09
7
9
8
10
U Man lser ua
The product warrranty is printed on the back of this guide.
This product is manufactured for use only in USA / CA.
This product is suitable for 120 V only.
L200 / L201Model Name:
Use & Care
Guide:
Ultrasonic Humidifier
IMPORTANT SAFETY INSTRUCTIONS
Thank you for purchasing a Winix Ultrasonic Humidifier. This product is for household use only.
Please read all instructions carefully before operating.
Do not repair or modify the unit. All repairs should be
completed by a qualified technician.
The plug for this unit is polarized with one blade wider than
the other. Do not force the plug into an electrical outlet.
Do not alter the plug in any way. If the plug does not
fit into the outlet, reverse the plug. If it still does not fit,
contact a qualified technician to install a proper outlet.
Do not use if the power cord or plug is damaged or
the connection to the wall outlet is loose.
Use AC 120 V only.
Do not damage, break, forcefully bend, pull, twist, bundle,
coat, pinch, or place heavy objects on the power cord.
Periodically remove dust from the power plug. This will
reduce the risk of shock due to humidity build up.
Remove the power plug from the outlet before cleaning
the unit. When removing the power plug, grasp by
holding the plug itself, never hold by the cord.
If the power plug is damaged, it must be replaced by
the manufacturer or a qualified technician.
Remove the power plug from the outlet when not in use.
Do not handle the power plug with wet hands.
Do not operate the unit when using indoor smoke-
generating insecticides.
Do not clean unit with benzene or paint thinner. Do not
spray insecticides on the unit.
Do not use the unit where it is humid or where the unit
may become wet, such as the bathroom.
Do not insert fingers or foreign objects into the air
intake or outlet.
Do not use the unit near flammable gases. Do not use
near cigarettes, incense, or other spark-creating items.
Unit will not remove carbon monoxide emitted from
heating appliances or other sources.
PRODUCT WARRANTY
Pressing the power button does not work
Insert the power plug carefully.
Check to see if there is water in the water tank. If not,
add water to the tank.
There's no steam coming out
Is the water tank empty?
-Please fill the tank with water more than halfway.
Is the nozzle and cover well seated?
-Please install the cover correctly.
Please clean the ultrasonic module.
It has a strong odor
Make sure the inside of the humidifier and the water
tank is not contaminated.
-Clean the inside of the main body and the water tank.
Did you leave water in the water tank and humidity
reservoir for an extended period?
-Dispose the remaining water from the main body
and the water tank from previous use. Refill the
water tank with new tap water.
The Empty Tank Alarm isn't turning off
Is this happening right after you set up the water tank?
-After a few moments,
the water in the water tank fills
the reservoir and the Empty Tank Alarm turns off.
Is it tilted?
-Drain the water inside the humidifier and place it
on a flat, stable surface.
FREQUENTLY ASKED QUESTIONS
The terms of the warranty are as follows:
1. This product is manufactured under stringent
quality control and inspections.
2. The warranty will be voided if product failure is
a result of negligence or misuse by the consumer.
Shipping and service fees may be incurred even
during the warranty period.
3. A proof of purchase must be presented upon
claiming a Product Warranty.
4. Store the proof of purchase in a safe place or
register your product on winixamerica.com to
upload your proof of purchase.
5. This warranty is valid only in the USA and Canada.
* for more information visit
https://winixamerica.com/terms-and-conditions/
Model Name L200 / L201
Warranty Period One (1) Year
Place of Purchas e
Place of Purchas e tel.
Customer
Address
Name
Tel.
This prouct is intended for household use only.
Never cover the unit while it is operating.
Always keep the cord away from high temperature and fire.
Perform regular maintenance on the ultrasonic
membrane.
Never use detergent to clean the ultrasonic membrane.
Do not attempt to adjust or repair the unit. Servicing must
be performed by a professional or qualified personnel.
Stop the unit if there is an unusual noise or smell.
Unplug this unit when not in use for a long period of
time.
Do not touch the water or any part of the unit that is
covered by water while the unit is on or plugged in.
Never operate without water in the tank.
Only use water in the tank.
Never use any additives in the water.
Keep this unit out of the reach of children. Do not allow
children to use this unit without supervision.
Do not use outdoors. For indoor use only.
W A R N I N G
Follow the instructions in this manual to reduce
the risk of electric shock, short circuit, and/or fire.
If the power cord is damaged, it must be replaced
with a special cord. Reassembly is available from the
manufacturer or its service agent.
This appliance is not intended for use by a person
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience or knowledge
about the unit, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure they do not play
with the appliance.
This unit is not intended to be used to preserve
documents or for art conservation.
Do not pull on the power cord when unplugging
the unit.
Do not tie or knot the power cord while unit is in
operation.
If the unit becomes submerged in water, unplug it
and contact customer service.
Do not unplug or move the unit while in operation.
Do not plug additional appliances into the same
outlet or power supply.
Do not touch the plug with wet hands.
Unplug the unit when not in operation for extended
periods of time.
Do not place around heating elements.
Do not use around mist or fumes from industrial oil
or around large quantities of metallic dust.
The cord can become damaged by forcefully
bending, pulling, twisting, bundling, pinching or
placing heavy objects on it.
Do not install in any sort of motor or transport
vehicle (trucks, boats, ships, etc.).
Do not place in an area with excessive amounts of
noxious gases.
Do not place near any flammable materials
(aerosols, fuel, gases, etc.).
Do not have the unit facing into wind or drafts.
Do not place below any electrical outlet.
Do not place in excessively humid areas where
the unit may become wet.
To reduce the risk of fire or electric shock,
do not use this appliance with any solid-state
speed control device.
SAFETY & CAUTIONS
UNIT SPECIFICATIONS
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 18 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
This device contains license-exempt transmitter(s) / receiver(s) that comply with Innovation, Science and Economic
Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the device.
Cet appareil contient des émetteurs/récepteurs exemptés de licence et conformes aux normes Innovation, Science
et Economic. RSS(s) sans licence de Développement Canada. Le fonctionnement est soumis aux deux conditions
suivantes:
cet appareil ne doit pas causer d’interférences nuisibles, et
cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant provoquer un fonctionnement
non souhaité.
Model Name
L200 / L201
Gallon Capacity
2.0 Gal / 7.5 L
Power V oltage
AC 120 V / 60 Hz
Warm Moistur e Output
Up to 350 mL/h
Power R ate
70 W
Runtime
Up to 120 hours
Weight
5.87 lbs / 2.67 kg
Product Dim ensions
10.6 in (W) × 8.5 in (D) × 14.6 in (H)
The exterior, design, and product specifications may be changed without prior notice to improve product performance.
FCC STATEMENTS
Dedicated Call Center: (877) 699-4649
Website: www.winixamerica.com
Contact Winix for
product related inquiries
and customer service
To expedite service, please specify the model name and number, the nature of the problem,
your contact information, and your address.
2610-0260-00 Rev. 02
Benefits of WINIX Pre-Soaked Aroma Pads:
New design and soothing relief: WINIX Waterless
Vaporizer Scent Pads are non-medicated refill pads
designed with Polymer PP to release soothing relief
vapors to enhance your humidification experience
and to help provide added comfort.
Provides long-lasting comfort per pad: Each pre-
soaked aroma pad offers 48 hours of long-lasting
comfort.
No spills or messy refilling: These refill pads are easy
to use and install, preventing messy spills and doing
away with the need for constant refilling.
These pads are designed for use with WINIX
Ultrasonic humidifier products: L100, L200, L201.
Humidifiers for bedrooms, desks, or tables: Our
humidifier helps add comfort wherever you are.
Uses Genuine
Demineralization Capsules
Questions or Orders:
(877)699-4649 info@winixinc.com
or visit: www.winixamerica.com
SKU: 1712-0111-00
Benefits of using WINIX Demineralization
Capsules:
(sold separately depending on model)
Reduces the mineral residue in your unit.
Results in less cleaning and lengthens the unit's
lifespan.
For optimal performance, replace each capsule every
5 tank fillings or when you notice an increase of white
residue.
The replacement period of the demineralization
capsule could differ based on the quality of water.
Consider using distilled water if white residue persists.
Never use water softening additives in your
humidifier.
LUNA2.0_EN.indd 2
LUNA2.0_EN.indd 2
LUNA2.0_EN.indd 2
LUNA2.0_EN.indd 2LUNA2.0_EN.indd 2 2020-10-22  5:54:10
2020-10-22  5:54:10
2020-10-22  5:54:10
2020-10-22  5:54:102020-10-22  5:54:10


Product specificaties

Merk: Winix
Categorie: Luchtbevochtigers
Model: L200

Heb je hulp nodig?

Als je hulp nodig hebt met Winix L200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden