WHALE Gusher 10 Mk3 Handleiding

WHALE Niet gecategoriseerd Gusher 10 Mk3

Lees hieronder de šŸ“– handleiding in het Nederlandse voor WHALE Gusher 10 Mk3 (8 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Thank you for purchasing this WhaleĀ® product.
For over 60 years WhaleĀ® has led the way in the design and manufacturer of water and waste systems
including:- plumbing, faucets, showers and pumps for low voltage applications. The company and its products have
built a reputation for quality, reliability and innovation backed up by excellent customer service.
For information on our full product range visit: www.whalepumps.com
CONTENTS
1. Principles of Operation
2. Specification
3. Application
4. Warnings
5. Parts List
6. Optional Extras
7. Installation
8. Maintenance
9. Trouble Shooting
10. Winterising
11. Service Support Details
12. EU Declaration of Conformity
13. Patents and Trademarks
14. Warranty
LIST OF IMAGES
Fig. 1 Through deck installation
Fig. 2 Incorrect installation
Fig. 3 Typical installation diagram
Fig. 4 Mounting arrangements for a standard model
Fig. 5 Dimensions
Fig. 6 Discharge point is well above the water line
Fig. 7 Deck fitting for Gusher Pumps (Half sectional elevation of deck fitting, pump and bracket)
Fig. 8 Exploded diagram
Read the following carefully before installation
To the Fitter:
Check that the product is suitable for the intended application. Follow these installation instructions and ensure all
relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the
end user. The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised
modification or misuse of the product.
To the User:
Read the following instructions carefully.
Whale GusherĀ®10 Mk3 Pump BP3708 / BP3740
INSTALLATIONā€ˆ&ā€ˆUSERā€ˆINSTRUCTIONS
1
This bilge pump is designed to exhaust standing water only. Manufactured from durable diecast alloy to withstand
tough marine conditions.
This bilge pump is suitable as a primary bilge pump on boats equal to or greater than 12m (40ft). Output capacity
depends on installation, conditions during use and pumping rate. Users should be aware that capacity may not be
sufficient to cope with rapid influx of water. If it is intended for any other purpose or with any other liquid, it is the
users responsibility to ensure that the pump is suitable for the intended use and, in particular, that the materials are
fully compatible with the liquids to be used.
ā€¢ The pump is designed to evacuate standing bilge water only. Bilge pump capacities may not be sufficient to
prevent flooding from rapid accumulation of water due to storms, rough weather and/ or rapid leaks created
by hull damage and or unsafe navigational conditions.
ā€¢ Fitting an inlet strainer will ensure the maximum efficiency of the pump.
ā€¢ This pump is not for use in systems evacuating water through a skin fitting or seacock below the waterline.
All pipework must contain a corectly installed anti-syphon valve/loop (next page see Fig 3 - Typical
installation diagram).
ā€¢Not suitable for pumping flammable liquids, diesel, chemicals etc. Suitable for bilge water only.
ā€¢ With all applications, it is important that a system of safe working practice is applied to installation, use and
maintenance. Ensure the waste water system is drained before installation. In order to securely fasten the
unit, ensure that the mounting surface is a minimum thickness of 18mm (45/64") as shown in Fig. 4
ā€¢NOTE Do not screw directly to the hull - must be mounted on a bulkhead or on an additional board.
1. PRINCIPLES OF OPERATION
4. WARNINGS
2. SPECIFICATION
Model On Deck / Bulkhead Thru Deck / Bulkhead
(includes deck plate)
Product Code BP3708 BP3740
Hose Connections 38 mm (1 1/2ā€) Smooth Hose Connections
Weight 2.3 kg (5 lbs)
Materials
Pump Body: Marine Grade LM6 Aluminium Alloy (epoxy coated).
Diaphragm: Neoprene (NitrileĀ®option available)
Fasteners: Stainless Steel
Materials In Contact With Fluid Marine Grade LM6 Aluminium Alloy (epoxy coated).
Neoprene, NitrileĀ®, Stainless Steel
Service Kit
AK3706 - Neoprene Parts
AK3714 - NitrileĀ® Parts for Oil &ā€ˆDiesel
Contains: Diaphragms, Valves, Gasket
Maximum Suction Lift 4 m (13.5ft)
Maximum Discharge Head 4 m (13.5ft)
3. APPLICATIONā€ˆ
Performance Data BP3708 / BP3740 BP3708 / BP3740
Suction Lift 1 m (3 ft) 2 m (6 ft)
Discharge Head 0.5 m (1.5 ft) 0.5 m (1.5 ft)
45 Strokes per Minute 41 ltrs (11 USā€ˆgals) 41 ltrs (11 USā€ˆgals)
70 Strokes per Minute 65 ltrs (17 US gals) 65 ltrs (17 US gals)
2
1 x Mk3 GusherĀ® 10 pump
1 x Stainless steel handle
(BP3740 includes deckplate)
1 x Mounting hole template
AS4405 -ā€ˆSpare handle
DP3804 - Metal deckplate & lid
DP8904 - Plastic deck plate
SB5865 - Strum box (top entry)
SB4222 - Strum box (side entry)
Please note that incorrect installation may invalidate the warranty.
LOCATION
Choose a position to mount the pump that is dry and away from standing water and is free from obstacles, where the
pump can be operated efficiently and comfortably. Ensure that the pump is installed to allow easy access for
servicing.
Avoid installation locations which require a cockpit locker to be opened in order to operate the pump.
To ensure good priming and flow:
ā€¢ Avoid sharp bends in pipework.
ā€¢ Fit a Whale strumbox / strainer part number SB4222 / SB5865
which prevents the end of the hose sucking against a flat
surface and allows the water level to be reduced to a minimum.
ā€¢ To minimise pumping effort, site the pump halfway (in height)
between the strumbox / strainer and hull outlet.
ā€¢ Mount in a position with the shortest run lengths possible.
ā€¢ Use a reinforced hose on inlet to prevent collapsing during suction.
The GusherĀ® 10 is designed for mounting on deck / bulkhead (BP3708), or
through deck / bulkhead (BP3740). The handle can be fixed on four different
positions relative to the inlet and outlet (see Fig. 4).
To Reposition Handle:
(a) Slacken wormdrive clip and remove diaphragm
(b) Undo the bolts from bracket and rotate body to new position relative to the fork and diaphragm. Note: Inlet
and outlet are always at 180 degrees to each other
(c) Reassemble bolts, washers and securing brushes in bracket and tighten
6. OPTIONAL EXTRAS
5. PARTSā€ˆLIST
Fig. 1 Through deck installation
7. INSTALLATION
Fig. 4 Mounting arrangements for a standard model
3
Fig. 2 Incorrect installation Fig 3 - Typical installation diagram


Product specificaties

Merk: WHALE
Categorie: Niet gecategoriseerd
Model: Gusher 10 Mk3

Heb je hulp nodig?

Als je hulp nodig hebt met WHALE Gusher 10 Mk3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd WHALE

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd