Westinghouse W24V2DP Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Westinghouse W24V2DP (2 pagina's) in de categorie Effect machine. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
1
SAVE THESE INSTRUCTIONS
mWARNING! READ AND UNDERSTAND ALL INSTRUCTIONS. Failure to follow all
instructions listed below may result in electric shock, fire and/or serious personal injury.
mCAUTION! To reduce the risk of injury, charge the 24V lithium-ion battery packs only in
its designated 24V lithium-ion charger. Other types of chargers present risk of fire,
personal injury and damage. Do not wire a battery pack to a power supply plug or car cigarette
lighter. Such misuse will permanently disable or damage the battery packs.
Avoid dangerous environments – Do not charge the battery packs in rain, snow or in
damp or wet locations. Do not use the battery packs or charger in the presence of explosive
atmospheres (gaseous fumes, dust or ammable materials) because sparks may be
generated when inserting or removing the battery pack, which could lead to a re.
Charge in a well-ventilated area – Do not block the charger vents. Keep them clear to allow
for proper ventilation. Do not allow smoking or open ames near a charging battery pack.
Vented gases may explode.
NOTE: The safe temperature range for the batteries is 41°F – 105ºF (5°C – 40.5°C). Do not
charge the batteries outside in freezing weather; charge it at room temperature.
Maintain charger cord – When unplugging the charger, pull the plug, not the cord, from
the receptacle to reduce the risk of damage to the electrical plug and cord. Never carry the
charger by its cord or yank it by the cord to disconnect it from the receptacle. Keep the cord
away from heat, oil and sharp edges. Make sure the cord will not be stepped on, tripped over
or subjected to damage or stress when the charger is in use. Do not use the charger with a
damaged cord or plug. Replace a damaged charger immediately.
Using the wrong, Do not use an extension cord unless it is absolutely necessary –
damaged or improperly wired extension cord poses a risk of re and electric shock.
The charger must be plugged into an appropriate Charger is rated for 120 volt AC only –
receptacle.
Use only recommended attachments – Use of an attachment not recommended or sold by
the battery charger or battery pack manufacturer may result in risk of re, electric shock or
personal injury.
Make sure to remove the battery packs from Unplug charger when not in use –
unplugged charger.
mWARNING! To reduce the risk of electric shock, always unplug the charger before
performing any cleaning or maintenance. Do not allow water to ow into the charger. Use a
Ground Fault Circuit Interrupter (GFCI) to reduce shock hazards.
Store your charger in a cool, dry place – Do not store charger where temperatures may
exceed 105ºF (40.5ºC), such as in direct sunlight or inside a vehicle or metal building during
the summer.
Charge times vary. Refer to battery specications.
Charger Input .................................................................................................120V AC, 60 Hz, W160
Charger Output ....................................................................................................... 26V DC, 2 x 2.2A
Battery Charge Level Indicator
Each battery pack is equipped with a push button for checking the charge level. Simply press the
push button to read o the battery charge level from the LEDs of the battery indicator:
When to Charge the Lithium-Ion Batteries
NOTE: The 24V lithium-ion battery packs do not develop a “memory” when charged after only
a partial discharge. Therefore, it is not necessary to run down the battery pack before
connecting it with the charger.
Use the battery charge indicator lights to determine when to charge your 24V
lithium-ion battery packs.
You can “top-off” your battery packs’ charge before starting a big job or after a
long day of use.
Charge the Battery
1. Press the push lock buttons on the battery to pull it out of the equipment.
2. Check that the mains voltage is the same as that marked on the rating plate of the battery
charger. Then, insert the charger’s plug into the electrical wall outlet. When you plug in the
charger, the top right green light will illuminate and stay green (Fig. ).1
3. Place the battery packs into the charger by sliding the packs to lock them into position.
When you insert the batteries into the charger, the two green lights will go off, and the red
lights will illuminate to indicate that the batteries are charging (Fig. 3).
SAFETY INSTRUCTION
TECHNICAL DATA
OPERATION
W24V2DP
24V 2x2 .2 AMP
DUAL CHARGER
FOR WESTINGHOUSE 24V BATTERIES
To register your Westinghouse battery pack on-line, visit us at:
wpowereq.com/pages/warranty-registration
All 3 A, B, C LEDs are lit: Battery charge level is high.
Light A, B LEDs are lit: Battery charge level is decreasing. Stop work as
soon as possible.
Light A LED is lit: Battery is flat. Stop work IMMEDIATELY and charge the
battery. Otherwise the battery’s service life will be greatly shortened.
* Generates 48 V max with two 24 V* lithium-ion batteries. Initial no-load voltage, per fully charged battery, peaks at 24 V*.
Nominal voltage under typical load is 21.6 V.
**Not compatible with 24V ystem batteries 8.0 Ah and above. S
2
4. When the charger lights turn green, the batteries are fully charged (Fig. 3).
NOTE: A fully discharged pack with an internal temperature in the normal range will fully
charge in 1 hrs and 50 mins (between 32°F/0°C and 113°F/45°C).
5. If the light indicators do not come on at all, check that the battery packs are fully seated into
the bay. Remove the battery packs and reinsert. If the problem persists, contact
Westinghouse Outdoor Power Equipment (855) 944-3571.
6. When charging is complete, remove the batteries from the charger by pressing the push
lock buttons and sliding the batteries upward to unlock them from the charger
(Fig. ).3
Charge a Hot or Cold Battery Pack
The green indicator light on the charger base indicates that the battery pack temperature is
outside the charging range. Once the pack is within the acceptable range, normal charging will
take place and the red light will be continuous. Hot or cold battery packs may take longer to
charge.
Battery + Charger O-Season Storage
1. Do not expose your battery pack or charger to water, rain or allow them to get wet. This s
could permanently damage the charger and the battery pack . Do not use oil or solvents to s
clean or lubricate your battery pack as the plastic casing can become brittle and crack, s
causing a serious risk of injury.
2. Store the battery pack and charger at room temperature away from moisture. Do not store s
in damp locations where corrosion of terminals may occur. As with other battery pack
types, permanent capacity loss can result if the battery packs are stored for long periods of
time at high temperatures (over 120ºF/49ºC).
3. 24V lithium-ion battery packs maintain their charge during storage longer than other battery
pack types. As a general practice, it is best to unplug the battery charger and remove the
battery packs when they are not in use. Recharge the battery packs every 6 60% months to
capacity (2 lights on) during off-season storage to maintain optimal battery performance.
If your lithium-ion charger requires service or maintenance, please call the Westinghouse
Westinghouse Outdoor Power Equipment (855) 944-3571.
When contacting the company, or arranging service from an authorized dealer, you will need to
provide the model and serial numbers, which can be found on the decal located on the housing
of the unit.
Federal Communications Commission (FCC)
Class B Device:
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Lithium-Ion Charging Status
Battery Pack
Temperature
Charger Base
Indicator Light
Battery Pack
Indicator Light Charging Status
Too hot Green Light C Flashing Not charging
Normal range Red Flashing one by one Normal charging
Too cold Green Not charging
SERVICE AND SUPPORT
MODEL + SERIAL NUMBER
Light C Flashing


Product specificaties

Merk: Westinghouse
Categorie: Effect machine
Model: W24V2DP

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse W24V2DP stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Effect machine Westinghouse

Handleiding Effect machine

Nieuwste handleidingen voor Effect machine