Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: Phone +39.0438.30.91.31 www.adfweb.com
User Manual
Modbus TCP Server
to Modbus RTU Master
Document code: MN67507_ENG Revision 1.102 Page 1 of 16
User Manual
Revision 1.102
English
Gateway / Bridge
Modbus TCP Server to Modbus RTU Master
(Order Code: HD67507 – HD67507M)
for Website information:
www.adfweb.com?Product=HD67507
for Price information:
www.adfweb.com?Price=HD67507
Benefits and Main Features:
Very easy to configure
Low Cost
Rail mountable
Wide supply input range
Galvanic Isolation
Industrial temperature range:
-30°C / 70 °C (-22°F / 158°F)
For others products for Modbus:
Converters / Adapters
See also the following links:
www.adfweb.com?Product=HD67118 (Modbus RTU Slave)
www.adfweb.com?Product=HD67119 (Modbus TCP Master)
www.adfweb.com?Product=HD67120 (Modbus TCP Slave)
For others Gateways / Bridges:
Modbus RTU Master / Slave
See also the following links:
www.adfweb.com?Product=HD67001 (CANopen)
www.adfweb.com?Product=HD67502 (CANopen)
www.adfweb.com?Product=HD67011 (CAN bus)
www.adfweb.com?Product=HD67012 (CAN bus)
Modbus TCP Client to Modbus RTU Slave
See also the following link:
www.adfweb.com?Product=HD67510
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
HD67507M
Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: Phone +39.0438.30.91.31 www.adfweb.com
User Manual Modbus TCP Server to Modbus RTU Master
Document code: MN67507_ENG Revision 1.102 Page 2 of 16
INDEX:
Page
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
CHARACTERISTICS 3
CONNECTION SCHEME 4
USE OF COMPOSITOR SW67507 7
NEW PROJECT / OPEN PROJECT 7
GENERAL PARAMETER 8
PING DEVICE 9
OPERATIONAL MODE: ROUTING 9
OPERATIONAL MODE: NATTING 9
TRANSLATE TABLE 10
UPDATE VIA TCP 12
UPDATE VIA SERIAL 13
CHARACTERISTICS OF THE CABLES 14
DETAILS ABOUT THE ETHERNET CABLE 14
MECHANICAL DIMENSIONS 15
ORDER CODE 15
ACCESSORIES 15
WARRANTIES AND TECHNICAL SUPPORT 16
RETURN POLICY 16
PRODUCTS AND RELATED DOCUMENTS 16
UPDATED DOCUMENTATION:
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code” that
appears at the top right-hand corner of each page of this document.
With this Document Code” go to web page www.adfweb.com/download/ and
search for the corresponding code on the page. Click on the proper “Document
Code” and download the updates.
To obtain the updated documentation for the product that you own, note the
“Document Code” (Abbreviated written "Doc. Code" on the label on the product)
and download the updated from our web site www.adfweb.com/download/
REVISION LIST:
Revision Date Author Chapter
Description
1.000 31/10/2008 Fl All First release version
1.100 17/11/2008 Fl All Enclosure Small
1.101 19/01/2009 Fl All Revision
1.102 03/07/2009 Ml All Revision
WARNING:
ADFweb.com reserves the right to change information in this manual about our
product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
All trademarks mentioned in this document belong to their respective owners.
Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: Phone +39.0438.30.91.31 www.adfweb.com
User Manual Modbus TCP Server to Modbus RTU Master
Document code: MN67507_ENG Revision 1.102 Page 3 of 16
CHARACTERISTICS:
The Modbus TCP to Modbus RTU Gateway allows the following characteristics:
Power supply 12...18 VAC or 12...24 VDC;
Opto-isolation RS485;
Choice possibility between RS232 or RS485;
Mountable on Rail DIN;
Temperature range -30°C to 70°C;
EMS EN 61000-6-2.
This device is able to manage a maximum of ten simultaneous connections from Ethernet side.
To configure the Gateway, use the available software that runs with Windows, called SW67507. It is downloadable on the site
www.adfweb.com and its operation is described in this document.
It can be used in two operative ways: routing and natting. In the “Routing Mode” the command Modbus is forwarded on the serial line using
the same requested addresses. In the “Natting Mode” the device addresses and data are altered through a translation table of the
addresses.


Product specificaties

Merk: Wachendorff
Categorie: Niet gecategoriseerd
Model: HD67507

Heb je hulp nodig?

Als je hulp nodig hebt met Wachendorff HD67507 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Wachendorff

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024
Senal

Senal ME-220-CL Handleiding

21 November 2024
Senal

Senal ASM-4 Handleiding

21 November 2024
Senal

Senal CS-88 Handleiding

21 November 2024
Senal

Senal CSP-162 Handleiding

21 November 2024
Senal

Senal ASM-3 Handleiding

21 November 2024
Senal

Senal ASM-5 Handleiding

21 November 2024