Ventus W210 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Ventus W210 (10 pagina's) in de categorie Weerstation. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Big Digit Multi-Channel Display Wireless Thermo-Hygrometer
with Self-Calibration & Auto-Night Light
Model: C2065A
User Manual
Thank you for purchasing this delicate Big Digit Multi-Channel Display
Wireless Thermo-Hygrometer with Self-Calibration & Auto-Night Light.
Utmost care has gone into the design and manufacture of the clock.
This manual is used for EU version. Please read the instructions
carefully according to the version you purchased and keep the manual
well for future reference.
OVE VIER W
MA UNIN IT
1. [ LIGHT ] key
- In normal mode, press once for 5-second backlight.
- When using the key to activate the backlight, operating [ LIGHT ]
other function keys will re-time the 5-second backlight.
- Press once to stop temperature and humidity alert sound.
2. [ CHANNEL / + ] key
- In temperature and humidity calibration mode, press to increase
the value.
- In normal mode, press to switch between , INDOOR Channel
1,2,3,4,5,6,7 8.and
- In normal mode, press and hold for 2 seconds to enter auto-
cycle mode that and ’s temperature Channel 4~8 INDOOR
and humidity readings will alternately be displayed at 4 second
intervals. The “ ” icon will display during auto-cycle mode.
- During auto-cycle mode, press once to return to normal mode.
3. [ MODE / ALERT ] key
- In temperature and humidity calibration mode, press once to
switch between setting options.
- In temperature and humidity calibration mode, press and hold for
- In normal mode, press and hold for 2 seconds to enter
temperature and humidity alert setting mode.
- In temperature and humidity alert setting mode, press once to
switch between setting options. Press and hold for 2 seconds to
4. key[ MEM / - ]
- In temperature and humidity calibration mode, press to decrease
the value.
- In normal mode, press once to check maximum and minimum
temperature and humidity records. Press again to return to
normal mode.
- When the maximum and minimum temperature and humidity
records are displayed, press and hold for 2 seconds to erase the
current records.
5. key[ TUNE ]
- In normal mode, press and hold for 2 seconds to enter
temperature and humidity calibration mode.
- In temperature and humidity calibration mode, press and hold for
2 seconds to return to normal mode.
6. [ ALERT ON / OFF]
- In temperature and humidity alert setting mode, press to turn on/
- Press once to stop alert sound.
7. Auto night-light slide switch
- Slide to position to activate night-light function. When it [ ON ]
is ON, the backlight will automatically turn on in dim and dark
environment detected by the light sensor. The brightness of night-
light is weaker than normal backlight.
- Slide to [ OFF ]
8. key[ °C / °F ]
- Press to switch between °C/°F.
9. key[ SENSOR ]
- In normal mode, press once to manually enter current channel’s
receiving mode. The unit will receive active sensor’s signals for 5
minutes and erase the current channel’s records.
10. [ RESET ] key
- Press once to perform overall function and display option resets.
- In case of malfunction, the unit may be required to reset.
WI ELES YG SE SOR S H R THEO- RMO N R
2
3
4
5
1
1. Transmission status LED
- Flash when the sensor is
transmitting.
2. Wall mounting holder
3. slide switch[ CHANNEL ]
- Assign the sensor to Channel
1,2,3,4,5,6,7 8 or .
4. key[ RESET ]
- Press to restart the sensor.
5. Battery compartment
- Accommodates 2 x AA size
batteries.
1
2
3
4
5
6
7
8
9
10
WIRELESS SENSOR
1. Remove the battery door of the sensor.
2. Insert 2 x AA size batteries into the battery compartment. Make
sure you insert them the right way according to the polarity
information marked on the battery compartment.
3. Close the battery door.
Note:
- Once the channel is assigned to one sensor, you can only
change it by removing the batteries or resetting the unit.
- Avoid placing the sensor in direct sunlight, rain or snow.
MAIN UNIT
1. Remove the battery door of the main unit.
2. Install 4 new AA size batteries according to the polarity
information marked on the battery compartment and then press
[ RESET ] key by using a metal wire to reset the unit.
3. Close the battery door.
4. Once the batteries are installed, all the segments of the LCD will
be shown.
Note:
To avoid the wireless sensor and main unit pairing failure, please
SRZHUXSWKHVHQVRUV¿UVWDQGWKHQSUHVV[ RESET ] key on the
main unit (no need on sensors).
INDOOR TEMPERATURE AND HUMIDITY FUNCTION
1. Press key to switch between °C/°F. Decimal point is [ °C / °F ]
HႇHFWLYHIRUERWKVHWWLQJV
2. When the temperature is below -40°C or above 70°C, “ ” or “ Lo Hi
will be displayed respectively. The humidity display will show “ ”.--
Temperature below -40°C Temperature above 70°C
3. When the humidity is below 1% or above 99%, “ ” or “ ” will be Lo Hi
indicated respectively.
Humidity below 1% Humidity above 99%
COMFORT INDICATION
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
Too cold Comfortable Too hot
Note:
- Comfort indication can vary under the same temperature,
depending on the humidity.
- There is no comfort indication when temperature is below 0°C
(32°F) or over 60°C (140°F).
TEMPERATURE & HUMIDITY TREND
The temperature & humidity trend indicator shows the trends of
changes in the forthcoming few minutes. Arrows indicate a rising,
steady or falling trend.
Arrow indicator
Trend Rising Steady Falling
TEMPERATURE AND HUMIDITY CALIBRATION
1. In normal mode, press and hold key for 2 seconds to [ TUNE ]
enter temperature and humidity calibration mode in which the
current outdoor channel or “IN [ CHANNEL ´LFRQZLOOÀDVK3UHVV
/ + ] [ MEM / - ] INDOOR or key to choose for or GLႇHUHQW
CHANNEL.
2. Press [ MODE / ALERT ] key again to switch between channel,
temperature and humidity. Press or [ CHANNEL / + ] [ MEM / - ]
key to adjust the value.
Choose Channel
3. key for 2 seconds or leave the unit :KHQ¿QLVKHGSUHVV[ TUNE ]
for 60 seconds to return to normal mode.
4. Pressing [ MODE / ALERT ] key for 2 seconds during
temperature and humidity calibration mode will reset the value to
the actual or uncalibrated measurement.
5. Reset the temperature and humidity values for each channel
individually. There is no batch reset.
6. &DOLEUDWLRQPRGHVHTXHQFHFKDQQHOĺWHPSHUDWXUHĺKXPLGLW\
7. In temperature calibration mode, press ] or[ CHANNEL / +
[ MEM / - ] key to modify 0.1 °C or °F of the value. Long press to
quick-adjust the value.
Temperature calibration mode
8. In humidity calibration mode, press ] or[ CHANNEL / + [ MEM
/ - ] key to modify 1% of the value. Long press to quick-adjust the
value.
Humidity calibration mode
9. If the current reading of the selected channel displays the
ÀDVKLQJ³-- Hi Lo”, “ ” or “ ”, it will be impossible to adjust. Pressing
[ CHANNEL / + ] [ MEM / - ] or key will not change the value.
10. If re-enter temperature and humidity calibration mode, the
adjusted value will reset to the original value.
11. The comfort indication is based on calibrated temperature and
humidity values to calculate.
MAX/MIN TEMPERATURE AND HUMIDITY RECORD
The unit preserves the MAX/MIN temperature and humidity records
since the last manual reset.
1. In normal mode, press key once to show the current [ MEM / - ]
maximum temperature and humidity values; press again to show
the minimum values; press the third time to return to normal
mode.
2. When the MAX/MIN records are shown, the display will return to
normal mode after leaving the unit for 5 seconds.
MAX records MIN records
3. Perform a manual reset or press and hold key for [ MEM / - ]
2 seconds when the unit is displaying MAX/MIN records or in
normal mode to erase the records.
Erase MAX/MIN records
WI ELES SE SO SIG EIVI ISPLR S N R NAL REC NG DAND AY
Signal receiving
1. In normal mode, press key once to start receiving [ SENSOR ]
and reset & the 4th row outdoor channel. The signal CH 1,2,3
For example, when & is displayed, pressing CH 1,2,3 6
[ SENSOR ] CH 1,2,3 6 key will receive & ’s signals.
2.
signal is received within 5 mins the icon will disappear.
3. If the reception fails, you can press key to restart [ SENSOR ]
pairing process for the on screen channels.
For example, when and are shown on the screen, CH1, 2, 3 5
pressing key will pair this 4 channels only. [ SENSOR ]
Receiving wireless signal after
manual reset or key [ SENSOR ]
is pressed
When waiting for signals, “--” will
Fair wireless sensor signal
The 4th row display
1. In normal mode, the 4th row display will show indoor data. “IN”
Press key repeatedly to switch to outdoor [ CHANNEL / + ]
channel .CH 4~8
2. In normal mode, press and hold key for 2 [ CHANNEL / + ]
seconds to toggle auto-cycle mode, which alternately displays the
channels at 4 second intervals. The “ ” icon will show on the
display.
3. During auto-cycle mode, press key once to [ CHANNEL / + ]
stop.
4. To check the validity of the signals of , press CH 6~8 [ CHANNEL
/ + ] key repeatedly in normal mode to display each channel.
Using auto-cycle mode will only display the communicated
channels.
For example, when and have received the signals from CH 6 8
the corresponding sensors, you can press and hold [ CHANNEL
/ + ] INDOOR CH 6 8 key for 2 seconds to auto-cycle , and ’s
display.
INDOOR CHANNEL 6 CHANNEL 8
5. If the wireless sensor’s signal has discontinued and does
not recover within 1 hour, the signal icon will disappear. The
temperature and humidity will display ” for the corresponding Er
channel.
6. If the signal does not recover within 48 hours, the “ ” display will Er
become permanent. You need to replace the batteries of the Er
channel’s sensors and then press key to pair up with [ SENSOR ]
the sensors per each “ ” channel again. (For , you need Er CH 4~6
pairing process.)
Signal discontinued
Note:
You need to press key to manually receive the sensor’s [ SENSOR ]
signal after you’ve placed the new batteries to the wireless sensor, or
the main unit fail to receive the wireless sensor’s signal.
A R NG D AYLE T SETTI AND ISPL
The unit can set up multiple temperature and humidity HI/LO alert for
indoor and up to 8 outdoor channels.
1. In normal mode, press and hold [ MODE / ALERT ] key for 2
seconds to enter alert setting mode. On the 4th row display, the
IN [ CHANNEL / + ] [ MEM / - ] or key to
choose the channel.
CHANNEL 1 INDOOR/CHANNEL 4~8
2. Press [ MODE / ALERT ] key to switch between channel,
temperature/humidity HI/LO alert setting.
CHANNEL 1
INDOOR/CHANNEL 4~8
3. Press or key to modify the value by [ CHANNEL / + ] [ MEM / - ]
0.1 °C/°F for temperature or 1% for humidity. Long press to quick-
adjust the value.
4. Press [ ALERT ON / OFF ]
regarding HI/LO alert.
5. [ MODE / ALERT ] key or without pressing
keys for 60 seconds. The display will return to normal mode.
6. 7KHVHWWLQJVHTXHQFHFKDQQHOĺWHPSHUDWXUHKLJKDOHUWĺ
WHPSHUDWXUHORZDOHUWĺKXPLGLW\KLJKDOHUWĺKXPLGLW\ORZDOHUW
ĺUHSHDW
7. Once the alert is set, you can clear the setting by hard resetting
the unit.
Note:
- The temperature alert setting range is -40°C~80°C. The humidity
alert setting range is 1%~99%.
- <RXFDQQRWHQWHUFRQÀLFWLQJ+,/2YDOXHVLQWKHVHWWLQJ)RU
example, if the HI temperature/humidity alert value is 40°C/%,
you cannot enter more than 39.9°C/% for the LO alert, and so
forth.
- When the alert is triggered, the alarm will sound and the alarm
LFRQRQWKHGLVSOD\ZLOOÀDVK3UHVV [ Light ] key to stop the alarm
sound. If you ignore the alarm, it will stop after 2 minutes.
- In normal mode, the 4th row display will switch from “ ” to the IN
current alarming channel. If another channel’s alarm is triggered
at that time, the 4th row display will switch to the latest alarming
channel and the 2 minutes alarm sound will re-time.
- If the alarm is ignored the 4th row will display the last alarmed
channel after 2 minutes.
- When the 4th row is in auto-cycle mode, if any alarm is triggered
the display will switch to the regarding channel. You can press
[ LIGHT ] [ ALERT ON / OFF ]or key or leave the unit for 2
minutes to stop the alarm. The display will return to auto-cycle
mode afterwards.
THE SNOW ICON
When the outdoor temperature is 3°C or below, the snow icon “
will display.
THE LOW BATTERY ICON
If the main unit or sensor is low in battery, the low battery icon
will display on the regarding / door channel section.IN OUT
For example, the sensor of is low in battery. When CHANNEL 4
CHANNEL 4 is displayed, the icon “ ” will show.
IMPORTANT NOTE
- Attention! Please dispose of used unit or batteries in an
ecologically safe manner.
- Always place the unit away from interfering sources such as TV
set, computer, etc.
- Avoid placing the unit on or next to metal plates.
- 7HFKQLFDOVSHFL¿FDWLRQVDQGXVHUPDQXDOFRQWHQWVIRUWKLVSURGXFW
are subject to change without notice.
SPECIFICATION
MAIN UNIT
Indoor operating temperature range -5°C ~ 50°C ( 23°F ~ 122°F )
Humidity display range 1% ~ 99 %
Resolution of temperature 0.1°C/°F
Resolution of humidity 1%
WIRELESS SENSOR
Outdoor operating temperature
range (based on Lithium battery)
-40°C ~ 60°C ( -40°F ~140°F)
Outdoor operating humidity range 1% ~ 99 %
Resolution of temperature 0.1°C/°F
Resolution of humidity 1%
Wireless sensor signal 433MHz
No. of remote sensor Up to 8 units
RF transmission range Maximum 30 meters
POWER
Main unit 1.5V AA x 4 (alkaline battery recommended)
Wireless sensor 1.5V AA x 2 (alkaline battery recommended)
DIMENSION
Main unit 130(W) x 112(H) x 27.5(D)mm
Wireless sensor 61(W) x 113.6(H) x 39.5(D)mm
1
2
3
4
5
6
7
8
9
10
2
3
4
5
1


Product specificaties

Merk: Ventus
Categorie: Weerstation
Model: W210

Heb je hulp nodig?

Als je hulp nodig hebt met Ventus W210 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Weerstation Ventus

Handleiding Weerstation

Nieuwste handleidingen voor Weerstation