User manual
Movement detectors
Read all instructions carefully
The
Sensor 140
and
Sensor 200
proximity switches are electronic switching devices
containing micro-disconnection (µ) according to EN 60669-2-1. The output circuit is activated
when a heat source moves in front of the device and is deactivated when no movement is
intercepted, after a settable period of elapsed time.
SAFETY WARNINGS
During installation and operation of the device, comply with the following instructions:
1) The device must be installed by a qualied person, in strict compliance with the
connection diagrams
2) Do not power on or connect the device if any part of it is damaged
3) In the building where the device is to be installed, there must be a switch and a
device for protection from overloads
4) Before touching the connector terminals make sure that the wires to be connected
are not live.
Code Model Description
VE212700 Sensor 140 Movement detector 140° - White
VE213500 Sensor 200 Movement detector 200° - White
VE787700 Sensor 200 Nero Movement detector 200° - Black
TECHNICAL CHARACTERISTICS
• Power supply: 230V AC 50Hz
• Beaking capacity: 5A 250V AC (resistive load)
• Maximum recommended loads:
− Incandescent light bulbs: 1000W
− Non-compensated uorescent: 500W
− Compensated uorescent: 250W
− Halogen (230V AC): 1000W
− Low consumption bulbs: 200W
• Consumption: 6VA (1W)
• Range of brightness: 5-30-2000 lux
• Intervention time: from 3 seconds to 30 minutes (approximate)
• Angle of detection: − Sensor 140: 140°
− Sensor 200: 200°
• Range of detection: − frontal 12m at 20°C
− lateral 8m at 20°C
• Operating temperature: -20 °C ÷ +40 °C
• Protection degree: IP55
• Insulation: class II
INSTALLATION
• The device must be installed far from inductive loads (motors, transformers, telephone
antennas, transformer plants, industrial machinery, etc.) as especially strong magnetic
elds may alter operation. The device must also be protected from sunlight. It must not
be placed near lights, near devices that are subject to temperature changes (heating, air
conditioning). It must be located far from highly reective surfaces.
Remove the cover by loosening the screw at the bottom. Fasten the base cover at the point
on the wall where you want to install it, at a height of 2-3 metres.
The direction of movement of the heat source must be transversal to lens of the device,
because detection occurs by means of intersection of bands. Therefore, if source moves
parallel to the bands, detection will occur at a lesser distance. The ambient temperature
also affects the sensitivity of the device. The higher the temperature, the poorer sensitivity
will be.
• The head can rotate horizontally about 180° and vertically about 45°.
• To adjust the eld of detection:
− turn the intervention time selector to the minimum and the brightness selector to ();
− check coverage by moving inside the eld of detection.
The device is also equipped with limiters of the detection area divided into four sectors. If
applied to the lens, they make it possible to exclude one or more of the sectors of the eld
of detection.
• To adjust the brightness, turn the selector towards ( ); when the ambient brightness is as
desired for operation, start turning the selector the other way, until illumination occurs.
• To adjust the intervention time, turn the selector ( ) to the desired position. You can
choose from a minimum of 3 seconds to a maximum of 30 minutes. This time is reset
each time there is an interception by the detector.
OPERATION
• At start and after each restoring of the power supply after a blackout, the sensor activates
the loads connected for 30 seconds, regardless of the brightness level and the actual
presence of movement in the eld of detection.
• During normal operation, when the level of brightness drops below the set level, the
device sets up for detection, and signals this condition via ashing of the internal LED.
REFERENCE STANDARDS
Conformity to the EU directives:
2014/35/EU (LDV)
2014/30/EU (EMCD)
is declared with reference to harmonized standard:
EN 60669-2-1
Dimensions
10072
80
Connection diagrams
L' N L
L
N
L' N L
230 V ACLAMPADINA
µ
BULB
Sensitivity
GREATER SENSITIVITY LESS SENSITIVITY
direction of
movement
direction of
movement
Field of detection
information to users pursuant to art. 14 of the directive
2012/19 / EU of the european parliament and of the council
of 4 july 2012 on waste electrical and electronic equipment (WEEE)
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general
waste at the end of its working life.
The user must take the worn product to a sorted waste center,
or return it to the retailer when purchasing a new one.
Products for disposal can be consigned free of charge (without any new purchase obligation)
to retailers with a sales area of at least 400 m
2, if they measure less than 25 cm.
An efficient sorted waste collection for the environmentally friendly disposal of the used device,
or its subsequent recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or
recycling of the construction materials.
ISCOM017-2106
Mod. Sensor 140
Sensor 200
Product specificaties
Merk: | Vemer |
Categorie: | Bewegingsmelders |
Model: | Sensor 140 |
Heb je hulp nodig?
Als je hulp nodig hebt met Vemer Sensor 140 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Bewegingsmelders Vemer
18 December 2022
20 Oktober 2022
Handleiding Bewegingsmelders
- Bewegingsmelders Bosch
- Bewegingsmelders Philips
- Bewegingsmelders Bticino
- Bewegingsmelders Honeywell
- Bewegingsmelders Alecto
- Bewegingsmelders Berker
- Bewegingsmelders Blaupunkt
- Bewegingsmelders Brennenstuhl
- Bewegingsmelders Devolo
- Bewegingsmelders Eminent
- Bewegingsmelders ESYLUX
- Bewegingsmelders Gira
- Bewegingsmelders Goobay
- Bewegingsmelders Hager
- Bewegingsmelders Hama
- Bewegingsmelders Hikvision
- Bewegingsmelders HQ
- Bewegingsmelders KlikaanKlikuit
- Bewegingsmelders Konig
- Bewegingsmelders Marmitek
- Bewegingsmelders Nedis
- Bewegingsmelders Niko
- Bewegingsmelders Perel
- Bewegingsmelders Renkforce
- Bewegingsmelders Schneider
- Bewegingsmelders Silvercrest
- Bewegingsmelders Smartwares
- Bewegingsmelders Steinel
- Bewegingsmelders Technaxx
- Bewegingsmelders Theben
- Bewegingsmelders TP Link
- Bewegingsmelders Velleman
- Bewegingsmelders Optex
- Bewegingsmelders Orbis
- Bewegingsmelders Arlo
- Bewegingsmelders DSC
- Bewegingsmelders Merten
- Bewegingsmelders Chacon
- Bewegingsmelders Chamberlain
- Bewegingsmelders Black Box
- Bewegingsmelders Speed-Link
- Bewegingsmelders Busch-Jaeger
- Bewegingsmelders EVE
Nieuwste handleidingen voor Bewegingsmelders
7 Februari 2023
7 Februari 2023
7 Februari 2023
7 Februari 2023
7 Februari 2023
6 Februari 2023
6 Februari 2023
4 Februari 2023
4 Februari 2023
4 Februari 2023