Valcom PagePro SIP VIP-204 Handleiding

Valcom Server PagePro SIP VIP-204

Lees hieronder de 📖 handleiding in het Nederlandse voor Valcom PagePro SIP VIP-204 (4 pagina's) in de categorie Server. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1 947694
ISSUE 6
PagePro VIP-204
SIP Paging Gateway
INTRODUCTION
The VIP-204 SIP Paging Gateway is designed for
use with virtually all IP based telephone systems.
The unit provides SIP addressable groups and 4
analog outputs that may be included as part of
the SIP addressable groups. The VIP-204 can
control thousands of IP speakers and/or analog
speakers or provide an interface to legacy paging
systems.
Connection to a SIP server can be as individual
SIP Stations (extensions) or as a SIP trunk.
Station mode provides up to 8 SIP-adressable
groups. Trunk mode accepts up to 100 SIP
phone numbers for flexible grouping.
SPECIFICATIONS
Access Methods
SIP
Valcom Multicast Page Group
Features
SIP – Addressable Groups (phone numbers)
4 Analog Audio Outputs (for inclusion in
groups only)
4 Programmable Form A Relay Closures
RJ-45 for Network Connection
Provides Audio for Valcom Analog One-Way
Self Amplified Speaker Assemblies or 25/70
Volt central amplifiers
AUX Audio Input via RCA Jack
Background Music Input, Music Mutes During
a Page
Output Control Relay Closure Provided
During Paging Output
2.5mm Jack for optional DC Power (non-
PoE)
LED Status Indicator
Network Activity LEDs
Programmable Feedback Elimination/Page
Repeat
Programmable Night Ring
Power Options
Power over Ethernet (PoE) 802.3af, Class 3
Compatible
Optional External Power Supply (VIP-324D)
Dimensions/Weight
1 Standard 19” Rack Unit:
1.75” H x 16.6" W x 9.5" D
(4.57 cm x 42.16 cm x 24.13 cm)
Weight: 7.25 lbs. (3.28 kg)
Nominal Specifications
AUX Input Impedance: 8 to 600 Ohms
AUX Input Level: -10dBm nominal
Output Impedance: 50 Ohms
Output Level: - 10dBm nominal
Relay Current Rating: 1 Amp @ 24VDC
Nominal Power Requirements
Via rear panel barrel connector:
Voltage: 24VDC
Current: 325mA
Via 802.3af PoE Ethernet Switch: Class 3
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% Non-Precipitating
Packing List
Qty Item
1 VIP-204
4 RJ-45 Patch Cables
4 VM-186 RJ-45 Connectors
4 Rubber Pads
2 Mounting Brackets W/ Hardware
1 VSP Document
2
CAUTION: To reduce the risk of electric shock,
Do not remove cover.
No user serviceable parts inside.
Refer servicing to qualified service pe rsonnel.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This sym bol indicates that dangerous
voltage constituting a risk of electric
shock is present with in this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This
equipment generates, uses and can radiate
radio frequency energy and if not installed
and used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area may cause
harmful interference in which case the user
will be required to correct the interference at
their own expense.
Precautionary Designations
Mounting
The VIP-204 SIP Paging Gateway is designed for
rack, shelf, or wall mounting.
Rack: Attach the brackets to the four holes
closest to the front on each side, and then mount
the unit to a 19” rack.
Shelf: Provided with the VIP-204 SIP Paging
Gateway are four rubber stick-on pads. Peel the
pads from their carrier backing and place at the
four corners of the bottom of the unit.
Wall: Using the brackets and wood screws
provided, secure the VIP-204 SIP Paging
Gateway to the wall.
Power Connections
The preferred method of powering a VIP-204 is
via a Power over Ethernet switch meeting the
802.3af specification.
If the rear panel barrel connector is used for
power, the preferred power supply is a Valcom
VIP-324D.
Make all required signal connections before
applying power to the unit.
Network Connection
The VIP-204 has one RJ-45 network connector
on the front panel.
Use a standard Ethernet patch cables to connect
the VIP-204 to an Ethernet switch. If the Ethernet
switch is 802.3af compliant, it will power the VIP-
204.
Signal Connections
The VIP-204 has 5 signal connectors on the rear
panel:
• 1 RCA jack for AUX audio input
• 4 RJ-45 connectors for audio and relay
connections for each networked channel.
AUX Input: Local audio may be input via the
rear panel RCA jack. Nominal input impedance
is 600 Ohms. Connect any compatible audio
source using an RCA patch cable. Audio
supplied through the rear panel RCA jack
broadcasts to all Audio Outs whenever they are
idle. This is typically used for background music.
Input / Output Connections: Access to the
audio output and relay output for each of the four
channels is provided through the four RJ-45 jacks
on the rear panel of the VIP-204. Four patch
cables and four VM-186 terminal block
connectors are included for ease of installation.
The following chart shows the pin assignments
for the four input/output connections.
N.O. Relay Closure Output: The Normally
Open Relay Closure Output connection can be
programmed on the VIP-204 to close the contacts
in response to paging events. The relay will
return to the open state when the event ends.
Audio Output: Typically connects to Self
Amplified Speakers or into an amplifier. Audio
feeds connected to the AUX Input mute on any
active Audio Output.
VM-186 Connector
Wire Color Signal
Blue & Blue/White N.O. Relay Closure
Output
Brown & Brown/White Audio Output
3
AUX
IN
+24VDC
PORT4PORT 3PORT 2PORT 1
RJ-45 PATCH CABLE
VIP-204 (REAR VIEW)
VM-186
RJ45
BLUE
ORANGE
GREEN
BROWN
BROWN
BLUE
N/O RELAY OUTPUT
AUDIO OUTPUT (TO SPEAKERS)
WHITE/BLUE
BLUE
WHITE/ORANGE
ORANGE
WHITE/GREEN
GREEN
WHITE/BROWN
BROWN
VIP-204 Audio/Relay Connections (one per channel)
Status Indicator Lights
The VIP-204 Network Interface has 3 status
indication lights:
STATUS: Flashes during normal operation and
solid during system startup.
LINK: Indicates a 100 Mbit Ethernet connection
when illuminated. A non-illuminated LINK LED
indicates a 10 Mbit connection or no network
connection.
ACT: Indicator flashes to indicate network activity
Operation
Provides paging from SIP connection or from
another Valcom VIP unit. Interface to customer
telephone system can be via SIP registration,
FXO port (with VIP-811), or FXS port (with
VIP-821). Unit can also be accessed from a
VIP-801 connected to a page port or a Valcom
page control.
Setup
Information specific to your application will need
to be programmed into the VIP-204. The PC
used for programming should be connected to
the same subnet as the VIP-204.
Setup will be done using the IP Solutions Setup
Tool. Download the latest version of the free IP
Solutions Setup Tool from the web site at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
Assistance in troubleshooting is available from
the factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
support@valcom.com.
Valcom equipment is not field repairable.
Valcom, Inc. maintains service facilities in
Roanoke, VA. Should repairs be necessary,
attach a tag to the unit clearly stating your
company name, address, phone number, contact
person and the nature of the problem. Send the
unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056


Product specificaties

Merk: Valcom
Categorie: Server
Model: PagePro SIP VIP-204
Kleur van het product: Zilver
Aantal Ethernet LAN (RJ-45)-poorten: 1
Spanning: 24 V
Ondersteunde protocollen: IETF SIP (RFC3261), IETF IGMP 3 (RFC3376), IETF RTP (RFC1889), IETF RFC2833\nDHCP, NTP
Afmetingen (B x D x H): 421.6 x 241 x 45.7 mm
Relatieve vochtigheid in bedrijf (V-V): 0 - 85 procent

Heb je hulp nodig?

Als je hulp nodig hebt met Valcom PagePro SIP VIP-204 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Server Valcom

Handleiding Server

Nieuwste handleidingen voor Server