V-Tac VT-80360 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor V-Tac VT-80360 (4 pagina's) in de categorie Bewegingsdetector. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
In case of any query/issue with the product, please reach out to us at: support@v-tac.eu
For More products range, inquiry please contact our distributor or nearest dealers.
V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000, bul.L.Karavelow 9B
INSTRUCTION MANUAL
MICROWAVE SENSOR DOWNLIGHT TYPE-ADJUSTABLE
MULTI-LANGUAGE
MANUAL QR CODE
Please scan the QR code to
access the manual in multiple languages.
TECHNICAL DATA
MODEL VT-80360
SKU 23165
INPUT POWER AC: 220-240V, 50/60 Hz
RATED LOAD Max. 1200W
300W +LED
TIME DELAY Min. 10sec Ā±3sec
Max. 12min Ā±1min
DETECTION
RANGE 360Ā°
DETECTION
DISTANCE 1-8m (Radius), Adjustable
DETECTION
MOVING SPEED 0.6-1.5m/s
WORKING
TEMPERATURE -20Ā°C to +40Ā°C
POWER
CONSUMPTION Approx, 0.5W
AMBIENT LIGHT <3-2000 LUX (Adjustable)
INSTALLATION
HEIGHT 1.5-3.5m
POWER
CONSUMPTION approx w0.9
DETECTION
MOTION SPEED 0.6-1.5 m/s
IP RATING IP20
HF SYSTEM 5.8Ghz CW Radar, ISM
Band
DIMENSION Ƙ80x66.6 mm
INTRODUCTION & WARRANTY
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best. Please read these instructions
carefully before starting the installation and keep this manual handy for future reference. If you have any another
query, please contact our dealer or local vendor from whom you have purchased the product. They are trained
and ready to serve you at the best. The warranty is valid for 5 years from the date of purchase. The warranty
does not apply to damage caused by incorrect installation or abnormal wear and tear. The company gives no
warranty against damage to any surface due to incorrect removal and installation of the product.
V-TAC LED
RANGE (UPTO 400W)
COMPATIBLE WITH
This marking indicates that this prod-
uct should not be disposed of with
other household wastes.
Caution, risk of electric shock.
FUNCTION
WARNING
1. Please make sure to turn oīš¦ the power before starting the installation.
2. Installation must be performed by a qualiļ¬ed electrician.
3. For Indoor use only
1. Can identify day and night: It can work in the daytime and at night when it is adjusted on the
ā€œsunā€ position (max). It can work in the ambient light less than 3LUX when it is adjusted on the
ā€œ3ā€ position (min). As for the adjustment pattern, please refer to the testing pattern.
2. SENS adjustable: It can be adjusted according to using location. The detection distance of low
sensitivity could be only 2m and high sensitivity could be 16m which ļ¬ts for large room.
3. Time-Delay is added continually: When it receives the second induction signals within the ļ¬rst
induction, it will restart to time from the moment.
4. Timeā€“Delay is adjustable. It can be set according to the consumerā€™s desire. The minimum time
is 10secĀ±3sec. The maximum is 12minĀ±1min.
NOTE: the high-frequency output of the HF sensor is
<0.2Mw- that is just one 5000th of the transmission power
of a mobile phone or the output of a microwave oven, the
baby can not touch it
INSTALLATION
1. Swing the plastic cover a little and adjust time and LUX knob.
2. Unload the transparent vinyl cover, loose the screws in the connection terminal, and then
connect the power to connection terminal of sensor according to connection-wire diagram.
3. Fold the metal spring of the sensor upwards, until they are in ā€œIā€ position with sensor, and
then put the sensor into the hole or installation box which is on the ceiling and has the similar
size with the sensor. Releasing the spring, the sensor will be set in this installation position.
4. Aīš®er ļ¬nishing installing, turn on the power and then test it
STEP 1
STEP 2 STEP 3
ā€¢ Turn the LUX knob clockwise on the maximum (sun). Turn the SENS knob clockwise on
the maximum (+). Turn the TIME knob anti-clockwise on the minimum (10s).
ā€¢ When you switch on the power, the light will be on at once. And 10secĀ±3sec later the
light will be oīš¦ automatically. Then if the sensor receives induction signal again, it can
work normally.
ā€¢ When the sensor receives the second induction signals within the ļ¬rst induction, it will
restart to time from the moment.
ā€¢ Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is less than 3LUX
(darkness), the inductor load could work when it receives induction signal.
CONNECTION-WIRE DIAGRAM
TEST
Note: When testing in daylight, please turn LUX knob to (SUN) position, otherwise the ā˜¼
sensor could not work!


Product specificaties

Merk: V-Tac
Categorie: Bewegingsdetector
Model: VT-80360

Heb je hulp nodig?

Als je hulp nodig hebt met V-Tac VT-80360 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsdetector V-Tac

V-Tac

V-Tac VT-8092 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-8091 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81014 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81013 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81012 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81011 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81010 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81009 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-81007 Handleiding

17 Augustus 2024
V-Tac

V-Tac VT-80360 Handleiding

17 Augustus 2024

Handleiding Bewegingsdetector

Nieuwste handleidingen voor Bewegingsdetector

Lucide

Lucide Eclips Handleiding

20 November 2024
Megatron

Megatron MT68030 Handleiding

19 November 2024
Megatron

Megatron MT68032 Handleiding

19 November 2024
D-Link

D-Link DCH-S150 Handleiding

16 November 2024
Hager

Hager TXD503 Handleiding

16 November 2024
Maxsa

Maxsa 40234 Handleiding

11 September 2024
Maxsa

Maxsa 43218 Handleiding

11 September 2024
ORNO

ORNO OR-CR-233 Handleiding

9 September 2024