WARNING!
1. Please make sure to turn off the power before starting the installation.
2. The light source of this luminaire is not replaceable, when the light source reaches its
end of life the whole luminaire should be replaced.
2. Installation should only be done by a certified electrician.
WEEE Number: 80133970
INSTALLATION INSTRUCTION
NEON FLEX LIGHT
This marking indicates that this
product should not be disposed of
with other household wastes.
Caution, risk of electric
shock.
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU
FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS.
V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B
TECHNICAL DATA:
2
YEARS
WARRANTY
*
IP65
RATING
Model Was Lumens
Beam
Angle
Body Type CRI
PCB
Width
Roll/M
LED
QTY/M
Opera on
Temperature
VT-559 13 1000 120° Silicone >80 8mm 10 120 -20 to +60°c
VT-560 8 530 120° Silicone >90 4mm 5 238 -20 to +60°c
VT-555 8 320 160° Silicone >80 5mm 10 120 -20 to +60°c
INTRODUCTION
Attention
!
vertically bending
Cutting instruction
SAFETY INSTRUCTION AND WARNINGS!
1. Please cut the LED Neon Flex according to the cutting as shown in the cutting instruc-
tions. Cutting outside the marking will damage the product. Please cut only on the
dotted/scissor marking on the LED Neon Flex. End Cap required.
2. LED Neon Flex cannot be folded, bent or twisted during the installation. Please install
in straight direction. DO NOT turn on power until LED Neon Flex is connected properly
and well-installed.
3. DO NOT touch/cut the LED Neon Flex when power is on.
4. DO NOT power the LED Neon Flex in roll/package.
5. DO NOT install in water or flammable environment, and make sure well ventilated.
6. DO NOT wrap or cover LED Neon Flex with any objects. Additional waterproof measure
needed when used outdoors.
7. DO NOT directly connect LED Neon Flex to AC power. Special power plug is needed.
8. If LED Neon Flex does not work when Power is on, please check "+" and "-" polarity.
9. When selecting power supply always add additional 10% to the maximum load.
10. DO NOT use excessive wire length between the power supply and LED Neon Flex to
avoid voltage drop
Thank you for selecting and buying V-TAC product. V-TAC will serve you the best.
Please read these instructions carefully before starting the installing and keep this
manual handy for future reference. If you have any another query, please contact
our dealer or local vendor from whom you have purchased the product. They are
trained and ready to serve you at the best. The warranty is valid for 2 years from
the date of purchase. The warranty does not apply to damage caused by incorrect
installation or abnormal wear and tear. The company gives no warranty against
damage to any surface due to incorrect removal and installation of the product.
The products are suitable for 10-12 Hours Daily operation. Usage of product for 24
Hours a day would void the warranty. This product is warranted for manufacturing
defects only.
Please cut only on the dotted/scissor marking on the LED Neon Flex.
End Cap required.
>60°
INFORMATION CONCERNING INSTALLATION
1) Use only DC power Supply (kindly check the technical data sheet).
2) When selecting appropriate power supply, please take into account, the electric power
consumed by LED Neon Flex (kindly check the technical data sheet).
3) In case when section is longer than 5M/10M, we recommend to power strips from the
ends
11. Once the LED Neon flex is cut it loses its IP X5. To ensure and regain its IP use
Silicone and ensure the IP is secured. Place End Cap at the end of LED Neon Flex
REMARKS CONCERNING MAINTENANCE
1) Use dry delicate cloth for cleaning.
2) Switch off the LED Neon Flex, prior to cleaning and make sure that the plug is pulled
out of the outlet.
3) Please wait until the lamp cools down in case it is heated.
4) During cleaning, follow the general safety rules and always be careful.
REMARKS CONCERNING SAFETY
1) The product should be safeguarded from children and in any case, should not be the
subject of play.
2) If the product is damaged, it should not be used (Advisably for recycling).
3) To be used for indirect lighting/architectural purpose only.
4) The manufacturer is not responsible for any damage arisen from not following safety
instruction or misuse of product.
INSTALLATION INSTRUCTIONS
Step 1: Switch Off the power before starting the installation.
Step 2: Connect the LED Neon Flex polarity “+” and “-” to the driver’s polarity “+”
and “-”. Follow the wiring diagram to ensure the wiring is done correctly [Refer to
Figure 1].
DC24V Power
Red wire should be connected to positive (+) side of the power supply.
Black wire should be connected to negative (-) side of the power supply.
Figure 1
Step 3: Wire the AC input source to the power supply and the AC plug. Additional
waterproof measure needed when used outdoors.
Step 4: Switch on the power to test the light.
AC IN
DC OUT
N
L
Power Supply
AC Power
WIRING DIAGRAM
Live Supply Can be Red or Brown
Neutral Supply can be Blue or Black