Thank you for purchasing TOA's VM-3000 Series.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
VM-3000 Series
INTEGRATED VOICE EVACUATION SYSTEM
PLEASE READ THIS MANUAL FIRST!
1. COMPOSITION OF THE VX-3000 INSTRUCTION MANUAL ....................................................... 1
2. SAFETY PRECAUTIONS
2.1. Applicable to All Models ........................................................................................................... 2
2.2. Applicable to VM-3240VA, VM-3360VA, VM-3240E and VM-3360E ....................................... 3
2.3. Applicable to RM-300MF, RF-320F, RM-200M, and RM-210 .................................................. 5
2.4. Applicable to VP-2241, VP-2421, VP-2000DS and VX-200PS ................................................ 6
3. GENERAL DESCRIPTION ............................................................................................................. 7
4. FEATURES ..................................................................................................................................... 7
TABLE OF CONTENTS
1. COMPOSITION OF THE VX-3000 INSTRUCTION MANUAL
The VX-3000 system Instruction manual is divided into 4 parts.
Please read the proper manual for your purpose.
This manual
(PLEASE READ THIS MANUAL FIRST)
For persons who administer the system
operation and make necessary settings
For service personnel who makes modifications
inside the unit
Installation Manual
for Service Technicians Only
For broadcasting equipment operators and
equipment/wiring installers Operating Instructions
Setting Software Instructions
Separate Manual
(CD only)
Separate Manual
(CD only)
Separate Manual
(CD only)
2
2.1. Applicable to All Models
When Installing the Unit
• Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as
doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified
may result in fire or electric shock.
• Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface.
Doing so may result in the unit falling down and causing personal injury and/or property damage.
• Since the unit is designed for in-door use, do not install it outdoors. If installed outdoors, the aging of parts
causes the unit to fall off, resulting in personal injury. Also, when it gets wet with rain, there is a danger of
electric shock.
• Backup power shall be supplied from the stand-by power supply equipment designated by TOA. Using the
equipment other than designated may cause fire.
When the Unit is in Use
• To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage
components inside the unit. Refer all servicing to qualified service personnel.
• Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire or electric shock.
• Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as
this may result in fire or electric shock.
• Do not touch a plug during thunder and lightning, as this may result in electric shock.
2. SAFETY PRECAUTIONS
• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe
operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or
cautions regarding safety.
• After reading, keep this manual handy for future reference.
These safety precautions apply to the models below which make up the VM-3000 System.
• VM-3240VA, VM-3360VA, VM-3240E, and VM-3360E (VM-3000 Series Amplifiers)
• RM-300MF, RM-320F, RM-200M, and RM-210 (Remote Microphones
• VP-2241 and VP-2421 (VP Series Amplifiers)
• VX-2000DS and VX-200PS (Power Supply Units)
Safety precautions are described divided into the following categories: commonly applicable ones to all
models and the ones only to the equipment groups shown above.
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
WARNING
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.
3
When Installing the Unit
• Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric
shock.
• Note correct polarity (positive and negative orientation) when connecting the power supply cord. Reversed
polarity connections will cause damage to the unit.
• To avoid electric shocks, be sure to remove its power supply cord from the wall outlet when making
connections.
2.2. Applicable to VM-3240VA, VM-3360VA, VM-3240E and VM-3360E
When Installing the Unit
• Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power
cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power
cord, as doing so may result in fire or electric shock.
• Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe
as a catastrophic disaster may result.
• The apparatus shall be connected to a mains socket outlet with a protective earthing connection.
• The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily
accessible.
• An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the
electrical installation of the building.
• Terminals with the symbol are Hazardous Live and the external wiring connected to these terminals shall
be installed by instructed person or shall be done with ready made cords or leads.
• The apparatus must be securely attached according to instruction manual to prevent injury.
When the Unit is in Use
• Should the following irregularity be found during use, immediately switch off the power, disconnect the power
supply plug from the AC outlet and contact your nearest TOA dealer. Make no further attempt to operate the
unit in this condition as this may cause fire or electric shock.
· If you detect smoke or a strange smell coming from the unit.
· If water or any metallic object gets into the unit
· If the unit falls, or the unit case breaks
· If the power supply cord is damaged (exposure of the core, disconnection, etc.)
· If it is malfunctioning (no tone sounds.)
• When replacing the fuse, be sure to use the supplied one. Using any other fuse than supplied may cause re
or electric shock.
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
WARNING
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
CAUTION


Product specificaties

Merk: Toa
Categorie: Niet gecategoriseerd
Model: VX-2000DS AMQ

Heb je hulp nodig?

Als je hulp nodig hebt met Toa VX-2000DS AMQ stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Toa

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd