Techly I-ALARM Gas Detector Handleiding
Lees hieronder de đź“– handleiding in het Nederlandse voor Techly I-ALARM Gas Detector (4 pagina's) in de categorie Gasmelder. Deze handleiding was nuttig voor 41 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/4
Gas Detector
www.techly.com
EN
The product is an indoor combustible gas detector with
high stability, used for combustion gas leak detection. It
uses highly stable semiconductor gas sensor with fea-
tures of stable performance and low drift of sensitivity.
When it senses combustion gas leak that reaches the
alarm level, it will gives out alarm sound with red LED
flashing. The detector is applied in indoor areas where
combustion gas leaks may happen.
Product features
• Detect Natural Gas / LPG
• Wall Mounted
• High Reliability Semiconductor Sensor
• Manual Test Button
• MCU Processing
• Auto Reset After Gas Clears
• Auto-Check Sensor Failure
• Wireless Alarm Signal Transmission
• SMT Manufacture Technology, High Stability
Technical speciî…·cation
Installation
1. First please conî…·rm if your gas is heavier than air, or
lighterthan air. Heavier gases: LPG etc; Lighter gases: na-
tural gas, marsh gas etc.
2. Choose a suitable position to install the detector ac-
cording to the gas speciî…·c gravity. For detecting heavier
gases, installation height: 0.3 - 1.0m from floor, within
the radius of 1.5m from gas source. For detecting lighter
gases, installation height: 0.3-1.0m from ceiling, within
the radius of 1.5m from gas source (refer to the following
image).
3. Fix the attached installing base into a Wall î…·rmly with
screws and hang the detector.
4. When installing at home, keep the detector away
from gas cookers to avoid being roasted by flame. Do
not install the detector in places with heavy smoke and
oil which may cause false alarms or block the gas con-
vection holes of the detector, which aî…¶ects the detector
sensing sensitivity. Also do not install it near to exhaust
fans, windows, doors, and places with heavy vapor in
bathroom.
5. Correctly connect the wires. All wiring and installation
must accord with the National and Local eî…¶ective laws
and criteria. Improper connection will cause the detector
not alarm on gas leaking.
Installation guide layout
Operating instruction
1. The detector will work just simply by plug-in.
2. After plug-in, the power LED constant on green. With a
“Di” sound from buzzer, the detector enters into warming up
state.
Red and yellow LEDs flash alternatively. 3 minutes later, the-
LEDs go out and the detector goes into normal working state.
Testing with gas is forbidden during warming up.
3. When a combustible gas leak happened and reached the
given alarm level, the alarm LED will flash red and the buzzer
will give out “Di...Di...“ alarm sounds. Meanwhile, the detec-
tor will send out wireless alarm signal.
4. The detector checks sensor failure automatically during
working. For sensor failure, the Fault LED on yellow
constantly along with buzzer sounding. For this situation,
unplug the detector and contact your vendor. Do not take
apart the detector or try to repair it by yourself.
Register the detector in the alarm system
Switch to Connection Mode on the control panel. Press
the test button of the sensor twice. The control panel be-
eps once: the gas detector is registered. If you hear two
beeps,the detector has already been connected. To check
if the registration is complete, arm the system and trigger
the sensor again. If the siren rings out, the registration is
successful.
Testing
1. The detector has a self-test button for checking if the LEDs
and the buzzer work normally. Pressing the test button, the
red and yellow LEDs flash alternatively and the buzzer gives
out alarm sound and meanwhile the detector will sent out
Wireless alarm signal.
2. It is forbidden to test with a lighter directly towards the
gas convection holes. This may cause damage to the inside
sensor. Instead, gather the gas from a lighter into an empty
plastic bottle and point the bottle mouth towards the gas
convection holes to release the gathered gas for testing.
Failure analysis & treatments
Emergency alarm treatment
When the natural gas level in air around the detector rea-
ches or exceeds the given alarm level, the detector will
automatically enters into alarm state. Below treatments
are advised:
1.
Close the gas tube valve right away.
2.
Do not plug or unplug electrical appliances.
3.
Open Windows to circulate air.
4.
Inspect the gas leak reason and notify the related
department or professionals to inspect and handle the
leakage. If it turns out to be a false alarm, check if the
installing position is
improper.
Warning!
1. The product is a combustible gas detector. Can not be
used to detect toxic gases such as carbon monoxide.
2. Make sure proper wiring and power supply are applied.
Without normal power supply, the detector will fail to
work.
3. At working time, mild heat-up in housing surface is
normal.
4. Maintain the detector periodically as required in this
manual.
5. Use cleaner to vacuum the dust in surface every month.
6. Do not use any detergents or solvents to clean the
detector. Chemicals may cause permanent damage or
transient pollution to the sensor.
7. Avoid spraying air fresheners, hair gels, paints or other
aerosols near the detector.
8. Test the detector by a professional every year to as-
sure the detector sensitivity. If the detector fails to work
properly, repair or replace it asap.
9. The service life ofthe detector semiconductor gas sen-
sor is 5 years. Replace the detector immediately when
the service life expires.
10. The detector can reduce accidents happening, but can
not guarantee a hundred percent safety. For your securi-
ty, besides proper usage of the detector, pay attention to
build up safety conscious and take preventive measures
in daily life.
Rilevatore di Gas
IT
Il prodotto è un rivelatore di gas combustibile ad alta
stabilitĂ , utilizzato per la rivelazione di fughe di gas di
combustione. Esso utilizza un sensore a semicondutto-
re altamente stabile con prestazioni altrettanto stabili.
Quando rileva una fuga di gas di combustione che risulta
pericolosa, attiva subito l’allarme acustico e quello visivo
tramite LED rosso lampeggiante. Il sensore può essere
applicato in ambienti interni in cui possono veriî…·carsi
delle perdite di gas di combustione.
Caratteristiche del prodotto
• Rileva gas metano / GPL
• Installabile a muro
• Sensore a semiconduttore ad alta aî…ądabilitĂ
• Pulsante per test manuale
• Elaborazione tramite microprocessore
• Auto Reset dopo l’eliminazione del gas
• Auto-controllo di guasti del sensore
• Trasmissione wireless del segnale di allarme
• Tecnologia di fabbricazione SMT, elevata stabilitĂ
Speciî…·che tecniche
Installazione
1. In primo luogo vericare se il gas è più pesante o leg-
gero dell’aria. I gas più pesanti sono: GPL, ecc; i gas più
leggeri sono: gas naturale, gas metano ecc
2. Scegliere una posizione adatta per installare il rivela-
tore in base al peso speciî…·co del gas. Per il rilevamento
di gas più pesanti, si consiglia un’altezza di installazione
da 0,3 a 1,0 m dal pavimento, entro il raggio di 1,5 m dalla
fonte di gas. Per il rilevamento di gas più leggeri, l’altez-
za di installazione consigliata è da 0.3 a 1.0m dal sotto,
entro un raggio di 1,5 m dalla sorgente del gas (vedere
l’immagine seguente).
3. Fissare la base installata usando le viti e appendere il
rivelatore.
4. Quando si installa in una abitazione, tenere il rilevato-
re lontano dai fornelli a gas per evitare che venga brucia-
to dalla î…·amma. Non installare il rilevatore in luoghi con
presenza di fumo pesante e l’olio che potrebbero causare
falsi allarmi o bloccare i fori di convezione del gas del
rivelatore, influendo sulla sensibilità del sensore di rile-
vamento. Inoltre, non installare l’apparecchio nei pres-
si ventilatori, î…·nestre, porte, e luoghi con intensi vapori
come il bagno.
5. Collegare correttamente i î…·li. Tutto il cablaggio e in-
stallazione devono essere conformi alle leggi nazionali
e locali e ai criteri di sicurezza. Un collegamento erra-
to pregiudica la funzionalità del rilevatore e farà sì che
il rilevatore non sia in grado di veriî…·care la presenza di
perdite di gas.
www.techly.com
Product specificaties
Merk: | Techly |
Categorie: | Gasmelder |
Model: | I-ALARM Gas Detector |
Breedte: | 70 mm |
Diepte: | 40 mm |
Hoogte: | 110 mm |
Gebruikershandleiding: | Ja |
Stroombron: | AC |
LED-indicatoren: | Fault, Alarm, Power |
Geluidsalarm(en): | Ja |
Frequentie: | 433 MHz |
Spanning: | 220 V |
Ophangsysteem voor aan de muur: | Ja |
Transmissie-afstand: | 80 m |
AC-ingangsspanning: | 220 V |
Test knop: | Ja |
Alarm decibels: | 75 dB |
Gedetecteerde typen gas: | Methane, Natural gas |
Drempelwaarde gasdetectie: | 6 procent |
Heb je hulp nodig?
Als je hulp nodig hebt met Techly I-ALARM Gas Detector stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Gasmelder Techly
23 Juni 2023
Handleiding Gasmelder
- Gasmelder Abus
- Gasmelder Alecto
- Gasmelder AngelEye
- Gasmelder Elro
- Gasmelder Eminent
- Gasmelder FireAngel
- Gasmelder First Alert
- Gasmelder Gloria
- Gasmelder HQ
- Gasmelder Itron
- Gasmelder Konig
- Gasmelder Nedis
- Gasmelder Netatmo
- Gasmelder PCE Instruments
- Gasmelder Satel
- Gasmelder Smartwares
- Gasmelder Trotec
- Gasmelder Joy-it
- Gasmelder Nexa
- Gasmelder Fantini Cosmi
- Gasmelder Vemer
- Gasmelder Deltronic
- Gasmelder GEV
- Gasmelder Kidde
- Gasmelder Testo
- Gasmelder System Sensor
- Gasmelder Dahua Technology
- Gasmelder Carel
- Gasmelder Popp
- Gasmelder ORNO
- Gasmelder Airthings
- Gasmelder Vimar
- Gasmelder Pentatech
- Gasmelder WisuAlarm
- Gasmelder Schabus
- Gasmelder Gewiss
- Gasmelder Figaro
Nieuwste handleidingen voor Gasmelder
30 November 2024
24 November 2024
18 November 2024
17 November 2024
22 Oktober 2024
26 September 2024
24 September 2024
24 September 2024
3 Juli 2024
3 Juli 2024