Taylor 5460 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Taylor 5460 (1 pagina's) in de categorie Thermometer. Deze handleiding was nuttig voor 66 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
IN
M
T
OR / OUTDOOR
XIMUM / MINIMUM
RMOMETER
SEPARAT ED FLUID:
The liquid in this thermometer may
become separated or air bubbles may
also appear in the clear liquid on the
maximum side. This does not represent
defect or damage. To reunite heavy
liquid and eliminate air bubbles prior to
thermometer use, please perform the
following steps:
1. Hold thermometer at the top as shown
in Fig. 2 and strike the bottom end
sharply against the palm of the other
hand.
2. Next, grasp the thermometer at the
top (as in a tennis racquet grip, Fig.3)
and swing the thermometer downward
in an arc.
3. Repeat the above steps as necessary
to reunite the heavy liquid. If the Note:
steps above do not remove the air
bubbles or reunite the heavy liquid in
the columns completely, hold the
thermometer upright under hot tap
water so the water washes over the
temperature sensing bulb. Do NOT
allow the columns to rise about 130°F.
Hold the thermometer in an upright
position to cool to room temperature.
Wipe dry.
MOUNT ING
For accurate minimum/maximum
temperatures, always mount the
thermometer in an upright position. Do
not mount in direct sunlight or where
there is a great deal of reflected light.
To prevent further fluid separation, store
the thermometer in an upright, top end
up position.
RESE T TH ERM OMETER
Press and hold the center button, this
releases the markers. Hold until the
markers rest on top of the heavy liquid
columns. If the limit markers stick,
remove the red magnet from the
thermometer and place on the marker
and move it down to the top of the
liquid. Replace the magnet for future
use. To obtain best results from the
min/max thermometer, read and reset at
least once daily.
INDOOR/OUTDOOR
MAXIMUM / MINIMUM THERMOMETER
Temperature
Sensing Bulb
Reset
Button
Limit
Markers
Heavy
Liquid Columns
(Fig 2)
(Fig 3)
Large face with bold, easy-to-read numbers
Records highest and lowest daily temperatures
Convenient push button and magnet reset
Temperature range: -40°F to 120°F/ -40°C to 50°C


Product specificaties

Merk: Taylor
Categorie: Thermometer
Model: 5460

Heb je hulp nodig?

Als je hulp nodig hebt met Taylor 5460 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Taylor

Taylor

Taylor 5293767 Handleiding

18 Augustus 2023
Taylor

Taylor 481CR Handleiding

18 Augustus 2023
Taylor

Taylor 49562J Handleiding

18 Augustus 2023
Taylor

Taylor 6729 Handleiding

18 Augustus 2023
Taylor

Taylor 5267459 Handleiding

18 Augustus 2023
Taylor

Taylor 483CR Handleiding

18 Augustus 2023
Taylor

Taylor 92671T Handleiding

18 Augustus 2023
Taylor

Taylor 482CR Handleiding

18 Augustus 2023
Taylor

Taylor 6777 Handleiding

18 Augustus 2023
Taylor

Taylor 5460 Handleiding

18 Augustus 2023

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer

Owon

Owon TI219 Handleiding

21 December 2024
TFA

TFA 12.1004 Handleiding

21 December 2024
Optex

Optex PT-U80 Handleiding

16 December 2024
Optex

Optex PT-7LD Handleiding

16 December 2024
Ebro

Ebro TFI 260 Handleiding

15 December 2024
Ebro

Ebro TFI 54 Handleiding

15 December 2024
EMOS

EMOS E0522 Handleiding

13 December 2024
Senseca

Senseca PRO 111 Handleiding

11 December 2024