Taylor 5329 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Taylor 5329 (1 pagina's) in de categorie Thermometer. Deze handleiding was nuttig voor 55 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
COMPLETE ONE YEAR LIMITED WARRANTY
www.taylorusa.com
# 5329
©2018 Taylor Precision Products
Oak Brook, IL 60523
5329_4.26.18
Made in China
Place
Sticker
Here
INDOOR / OUTDOOR
THERMOMETER WITH HYGROMETER
Large, easy-to-read numbers
Humidity and temperature readings from inside
Indoor & outdoor temperature range: -50°F to 120°F / -45°C to 50°C
Indoor humidity range: 10%-80%
EXPOSURE:
Do not mount in direct sunlight, near a heat source, or near a large body of
water as these situations could affect the proper air temperature reading.
Ultraviolet light from sunlight can prematurely weather the product.
SEPARATED FLUID:
Under normal shipping conditions, the Permacolo
liquid in this thermometer may become separated. When
this occurs, the thermometer will not read accurately.
Should one of the tubes read substantially lower than the
other, it may be due to the fact that the liquid has
become separated, and is at the extreme top of the tube.
Such separation does not represent defect or damage.
The column may be reunited as follows:
1. Hold thermometer as shown in Fig. 2, supporting the
coil of tubing
2. Tap edge of thermometer lightly against palm of other
hand
3. Continue to tap lightly until column is reunited
MOUNTING INSTRUCTIONS:
Choose a window near which the thermometer is to be
installed, and where the bulb will be shielded from the
sun's rays. (North side is preferable for true air
temperature readings).
The tubing which connects the bulb to the outdoor
scale is liquid filled. Do not cut, disconnect or sharply
bend in a manner which may restrict the flow of liquid.
Make certain location chosen will permit ample tubing
to run along the window casing and over the frame as
illustrated (Fig. 1). For maximum accuracy, exactly 12"
(30.5cm) of tubing should be exposed to the outside
temperature.
Use the template guide at right to locate position for
mounting screws. Hold template against wall at location
selected for thermometer. Punch through cardboard at both dots until heads are
about 1/8" (2.8mm) from surface. Hang thermometer by means of keyhole slots in
backplate.
Form tubing over window casing as illustrated in Fig. 1, avoiding sharp bending.
Select either an upper or lower corner. Closing of the window must not crush the
tubing; if sufficient clearance does not exist, a small notch or groove should be
made with saw or file to provide for this. The same provision for clearance should be
made in storm sash of either permanent or removable type.
Using small screws , fasten outside bulb bracket and insert bulb.
FIG. 1
FIG. 2
REJOINING
SEPARATED FL UID
MOUNTING SCREWS TEMPL AT E - 4 1/2 INCHES
BLACK


Product specificaties

Merk: Taylor
Categorie: Thermometer
Model: 5329

Heb je hulp nodig?

Als je hulp nodig hebt met Taylor 5329 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Taylor

Taylor

Taylor 5293767 Handleiding

18 Augustus 2023
Taylor

Taylor 481CR Handleiding

18 Augustus 2023
Taylor

Taylor 49562J Handleiding

18 Augustus 2023
Taylor

Taylor 6729 Handleiding

18 Augustus 2023
Taylor

Taylor 5267459 Handleiding

18 Augustus 2023
Taylor

Taylor 483CR Handleiding

18 Augustus 2023
Taylor

Taylor 92671T Handleiding

18 Augustus 2023
Taylor

Taylor 482CR Handleiding

18 Augustus 2023
Taylor

Taylor 6777 Handleiding

18 Augustus 2023
Taylor

Taylor 5460 Handleiding

18 Augustus 2023

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer