Taylor 5286498 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Taylor 5286498 (2 pagina's) in de categorie Thermometer. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
5
52
28
86
64
49
98
8
T
Th
he
er
rm
mo
oc
co
ou
up
pl
le
e
T
Th
he
er
rm
mo
om
me
et
te
er
r
w
wi
it
th
h
K
K-
-T
Ty
yp
pe
e
P
Pr
ro
ob
be
e
Thank you for purchasing a Taylor® Thermocouple Probe Thermometer with K-type Probe. Please
read this instruction manual carefully before use. Keep these instructions handy for future
reference. Please remember to keep the unit away from children and do not use it for safety
related applications.
THERMOCOUPLE PROBE
The K-type thermocouple probe is used to measure internal food temperature quickly and
accurately. To use, insert the plug of a K-type thermocouple probe into the thermocouple socket on
the unit.
THERMOCOUPLE PROBE FUNCTION
After installing the probe, press the (Power) button to turn the unit on. Then simply insert the
probe into the food to be measured for a reading. The unit will continuously display temperatures
for up to 5 minutes. After that, the unit will automatically shut off to preserve battery life. Or, press
and hold the ‘ button for 3 seconds to turn the unit off manually.
1. Placing stress on the probe may cause breakage.
2. After measuring high temperatures, the probe may remain HOT for a while. Allow the probe
to cool before touching.
3. Use caution while handling the probe to avoid injury. Keep probe out of reach of children.
The probe may be damaged if used to measure a temperature that exceeds the specification
of the measurement temperature range.
To avoid electric shock and thermometer damage, do not measure a live circuit where the
voltage exceeds 24V AC RMS or 60V CD with the thermocouple probe.
°F OR °C MODE
To switch between ‘°F’ and ‘°C’, press the ‘ (Power) button to turn the unit on, then press the
‘“◦F/◦C’ button to switch between temperature scales.
HOLD FEATURE
When the digital display has been stabilized, press the "HOLD" button and the temperature will be
held ("Hold" will appear). Press again to release
BACKLIGHT FEATURE
The backlight will activate for 15 seconds when any button is pressed while the units is on.
RECALIBRATION
If recalibration is necessary, suspend probe at least 1” into a 'slush' of crushed ice and water (32°
F) for at least 1 minute. Keep the probe from touching the container bottom or sides. Press the
“HOLDbutton 3 times. “CALu” flashes on the LCD, indicating the thermometer is in calibration
mode. The calibration will reset to zero and the thermometer will automatically return to normal
temperature measurement.
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
‘ ’HHH or LLL is displayed when the temperature being measured is outside of
the measurement range.
‘ ’Lo indicates a low battery warning. Replace both batteries at the same time.
“ERR” is displayed when the thermometer is exposed to temperatures exceeding
122°F (50°C). Move the thermometer away from the heat source for at least 2
minutes until “ERR” disappears.
BATTERY INSTALLATION
The thermometer operates on 2 AAA ies (included). batter
1. Remove any plastic wrap from the batteries before proceeding.
2. Loosen the screw on the battery compartment cover on the back of the thermometer and
remove the compartment.
3. Install 2 “AAA” batteries into the battery compartment according to the “+” and “ polarity-
symbols in the battery compartment.
4. Replace the battery compartment cover and tighten the screw.
NOTE: Please recycle or dispose of batteries correctly per local regulations.
WARNING: Batteries may pose a choking hazard. Do not let children handle batteries. Keep
batteries away from children Do not dispose of unit or batteries in fire, as the . batteries inside this
unit may explode or leak.
STORAGE & CLEANING
Take care when cleaning the rmometer, using only a soft cloth or cotton swab with water or the
medical alcohol, allow the thermometer to fully dry before using it. Do not submerge any part and
of the thermometer. The thermometer should be stored at room temperature between -4 to +140°F
(-20 to +60 ). °C
SPECIFICATIONS
Item
K Type Thermocouple Probe
Probe Measurement Range
- to +662°F (-50 to +350°C) 58
Operating Range
-4 to +122°F (-20 to +50°C)
Resolution
0.1°F/0.1°C (-9.9~199.9°C)
Probe Response Time
2 seconds
Probe Accuracy
±1% of reading or 1.8°F (1°C), whichever is greater
Battery Life
Typically 1 year
Batteries
2 AAA batteries
LCD 1.476x1.157 inch (37.5x29.4mm)
4.488×2.205× 0.688 inch (114×56x17.5 mm)
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field a
strength of approximately 3 volts per meter, but the performance of the instrument will not be
permanently affected.
DO NOT keep the unit too close to objects that continuously generate high heat (such as a
hot plate) for long periods of time. This may cause the unit to overheat.
CARE AND PRECAUTIONS
1. Always read instructions thoroughly to ensure that you have the full benefit of all the unit's
f ures. eat
2. Keep thermometer and probe out of reach of all children.
3. DO NOT immerse unit in water, as doing so will cause damage to internal components and void
the warranty. If you spill liquid on it, dry it immediately with a soft, lint-free cloth. The unit is not
dishwasher safe. Damage will void warranty.
4. DO NOT clean the unit with an abrasive or corrosive material. This may scratch the plastic parts
and corrode the electronic circuits.
5. DO NOT subject the units to excessive force, shock, dust, temperature or humidity. This may
result in malfunction, shorter electronic life span, damaged battery and distorted parts.
6. DO NOT operate or store the unit in high temperature or humidity conditions. The heat or
moisture may interfere with the unit’s internal components. Store the unit at temperatures between
-4 0°F ( 20 and +14 and +60°C).
7. DO NOT tamper with the unit's internal components. Doing so will invalidate the warranty on the
unit and may cause damage. The unit contains no user-serviceable parts.
8. This unit operates on 2 AAA batteries. Do not dispose of this product or batteries in fire, as
batteries inside this product may explode or leak. Always replace both batteries at the same time;
do not combine old and new batteries. Do not mix Alkaline, carbon-zinc (standard) or
Nickel-Cadmium (rechargeable) batteries.
One Year Limited Warranty
Taylor warrants this product to be free from defects in materials or workmanship for one (1) year
(excluding batteries) for the original purchaser from date of original purchase. It does not cover
damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized
adjustment and/or repair. If service is required, do not return to distributor. For service, call
between 7:30 AM and 4:30 PM, Mountain Standard Time, Monday through Friday. To assist us in
servicing you, please have the model number and date of purchase available. Should this product
require service (or replacement at our option), please pack the item carefully and return it prepaid,
along with receipt showing date of purchase and a note explaining reason for return to:
Taylor Precision Products, Inc.
2220 Entrada del Sol, Suite A
Las Cruces, New Mexico 88001
Customer Service Phone: 1- - -4834 800 225
Customer Service Fax: 1-575- -526 4347
www.taylorusa.com
There are no expressed warranties except as listed above. This warranty gives you specific legal
rights, and you may have other rights which vary from state to state.
For additional product information, or warranty information outside the USA, please contact us
through www.taylorusa.com.
© 20 Taylor, a division of Lifetime Brands, Inc. All rights reserved. 21
Made to our exact specifications in China.
5286498 12 21EN .


Product specificaties

Merk: Taylor
Categorie: Thermometer
Model: 5286498

Heb je hulp nodig?

Als je hulp nodig hebt met Taylor 5286498 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermometer Taylor

Taylor

Taylor 5293767 Handleiding

18 Augustus 2023
Taylor

Taylor 481CR Handleiding

18 Augustus 2023
Taylor

Taylor 49562J Handleiding

18 Augustus 2023
Taylor

Taylor 6729 Handleiding

18 Augustus 2023
Taylor

Taylor 5267459 Handleiding

18 Augustus 2023
Taylor

Taylor 483CR Handleiding

18 Augustus 2023
Taylor

Taylor 92671T Handleiding

18 Augustus 2023
Taylor

Taylor 482CR Handleiding

18 Augustus 2023
Taylor

Taylor 6777 Handleiding

18 Augustus 2023
Taylor

Taylor 5460 Handleiding

18 Augustus 2023

Handleiding Thermometer

Nieuwste handleidingen voor Thermometer

Owon

Owon TI219 Handleiding

21 December 2024
TFA

TFA 12.1004 Handleiding

21 December 2024
Optex

Optex PT-U80 Handleiding

16 December 2024
Optex

Optex PT-7LD Handleiding

16 December 2024
Ebro

Ebro TFI 260 Handleiding

15 December 2024
Ebro

Ebro TFI 54 Handleiding

15 December 2024
EMOS

EMOS E0522 Handleiding

13 December 2024
Senseca

Senseca PRO 111 Handleiding

11 December 2024