Swann SW351-MD2 Handleiding

Swann Alarmsysteem SW351-MD2

Lees hieronder de 📖 handleiding in het Nederlandse voor Swann SW351-MD2 (4 pagina's) in de categorie Alarmsysteem. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
Operating Instructions
Magnetic Window
Alarm SW351-MDA
Advanced security made easy
222
Congratulations on your purchase of this stand-alone window alarm from ! This Swann
alarm unit is a simple, easy to install security device which will help you to protect one door
or window from unwanted intrusion.
This magnetic window alarm unit can effectively protect a single window (or door) being
opened, though it cannot prevent a window being broken. Thus, for more complete
protection of a window, we suggest using either infrared alarm or a glass breakage alarm
as a backup to the door alarm.
This package includes:
Magnetic Window Alarm
Double-Sided Mounting Tape
Operating Instructions
2
• Do not expose any part of the alarm unit to any sudden shocks (such as being dropped
or struck).
• Do not install the alarm unit near devices which generate magnetic fields (such as
microwaves).
• Do not install any the alarm unit in direct sunlight.
• Use only alkaline batteries.
• All components are for indoor use only. Do not install outdoors.
• Replace the batteries in the unit every six months.
• Test the alarm periodically (every 1 - 2 months and each time you change the
batteries) to ensure it is working properly.
• This alarm system is designed to be, and acts as, a theft deterrent. This system,
like any other, cannot offer complete protection for your home or business - it
is simply an alarm system. Like all practical systems, it has limitations and it could be
disabled by a skilled intruder. We suggest that you avoid relying solely on this magnetic
alarm unit to protect your property, but use it as part of a comprehensive security
solution. You can increase your level of protection through the use of high-quality
locks, stronger doors, guards for your windows and a CCTV system and recording
devices.
IMPORTANT - Read Before Installing
Overview
Battery Compartment
Siren Magnetic
Trigger
Battery
Indicator LED
Alarm Unit
33
How it works:
The sensor is composed of two separate, equally important parts: the alarm unit itself, and
the trigger. The alarm unit is the larger of the two parts, and is responsible for sounding the
alarm (hence the siren). Inside the transmitter is a magnetically sensitive switch, which is
held in the OFF position by the magnetic trigger.
When the trigger is moved farther than approximately 1/2” (10-15mm) away from the door
sensor, the switch closes to the ON position and the alarm is triggered.
Arming and Disarming
The arming/disarming switch is located underneath the battery compartment, just above
the battery slot. There are only two settings, ON and OFF. Whilst ON, the alarm will sound
whenever the two parts of the alarm are separated. Whilst OFF, the alarm will not sound
under any circumstances.
• To arm the sensor, simply set this switch to ON.
• To disarm the unit or stop an alarm in progress, set the switch to OFF.
Mounting
Included are two portions of double-sided tape, one for both the alarm unit and the
magnetic trigger.
1. Remove the plastic cover from one side of the larger piece of double sided tape, and
apply the tape to the rear side of the alarm unit.
2. Remove the plastic cover from one side of the smaller piece of mounting tape, and
apply to the rear of the magnetic sensor.
3. Clean the surfaces you want to mount the alarm on using cleaning alcohol or similar.
Ensure the surfaces are completely clean and dry before proceeding.
4. Remove the plastic cover from the other side of the double-sided tape, and apply one
part of the alarm to the door/window you want to monitor, and the other part to the
frame. Ensure that when the door/window is shut, the small black arrows on the sensor
and trigger line up. They don’t need to physically touch, but they should be no more
that 1/5”(5mm) apart when the door/window is shut for the sensor to work correctly.
Replacing Batteries
1. Open the battery compartment on the front of the of the sensor.
2. Remove any old batteries.
3. Place four fresh alkaline LR44 batteries into the sensor. The correct orientation is shown
on the base of the battery compartment.
4. Use only alkaline batteries. Do not use rechargeable batteries.
5. To test the curret state of your batteries, press the TEST button, located in the battery
compartment. If the Battery Indicator LED will lights up then the batteries have enough
power to operate the alarm. If it does not light up or is dim, then you should replace
the batteries as soon as possible.
Technical Specifications
Power Requirements 4 x LR44 Button Cell Batteries (6V DC)
Siren Duration 60s (approx.)
Siren Volume >110dB
Magnetic Switch Trigger Range 10mm ~ 26mm


Product specificaties

Merk: Swann
Categorie: Alarmsysteem
Model: SW351-MD2
Kleur van het product: Wit
Soort: LR44
Gebruikershandleiding: Ja
Accu/Batterij voltage: 6 V
Smartphone ondersteuning op afstand: Nee
Aantal gelijktijdig verbonden apparaten (max): 2
Aantal bewegingssensoren: - stuk(s)
Alarm decibels: 110 dB
Aantal deur-/raamsensoren: 2 stuk(s)

Heb je hulp nodig?

Als je hulp nodig hebt met Swann SW351-MD2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Alarmsysteem Swann

Handleiding Alarmsysteem

Nieuwste handleidingen voor Alarmsysteem

Hager

Hager RLF444X Handleiding

3 December 2024
Hager

Hager RLF620X Handleiding

3 December 2024
Hager

Hager S163-22X Handleiding

3 December 2024
Hager

Hager S272-22F Handleiding

3 December 2024
Hager

Hager RLF001X Handleiding

3 December 2024
Hager

Hager S121-22X Handleiding

3 December 2024
Hager

Hager RLD414X Handleiding

3 December 2024
Hager

Hager RLD454F Handleiding

3 December 2024
Hager

Hager RLF660X Handleiding

3 December 2024
Hager

Hager RLA176X Handleiding

3 December 2024