Supermicro SuperServer SYS-120TP-DC9TR Handleiding
Supermicro
Server
SuperServer SYS-120TP-DC9TR
Lees hieronder de 📖 handleiding in het Nederlandse voor Supermicro SuperServer SYS-120TP-DC9TR (1 pagina's) in de categorie Server. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/1
SuperServer 120TP-DTTR/DC8TR/DC9TR Quick Reference Guide
UID Button
Power Button
Information LED
NIC LED
1
2
3
4
Power LED5
DescriptionNo.
Board Layout
Caution and Product Resources
NODE
UID
NODE
UID
UID
4 53
1 2
A
B
Serverboard
A
Serverboard
B
Serverboard Drawer Locations in the Chassis
Serverboard A Controls HDDs A0 through A4
Serverboard B Controls HDDs B0 through B4
http://www.supermicro.com MNL-2441-QRG Rev. 1.0
IMPORTANT: See installation instructions and safety warning before
connecting system to power supply.
http://www.supermicro.com/about/policies/safety_information.cfm
SAFETY INFORMATION:
Always be sure all power supplies for this system have the same power output.
If mixed power supplies are installed, the systemwill not operate.
CAUTION:
To reduce risk of electric shock/damage to equipment, disconnect power from
server by disconnecting all power cords from electrical outlets.
If any CPU socket empty, install protective plastic CPU cap.
WARNING:
CAUTION:
This unit has redundant power sources.
Please disconnect all the power cords before servicing.
For more information go to: http://www.supermicro.com/support
PRODUCT RESOURCES:
A1
A0
A3
A2
B1
B0
B3
B2
1 2 543 6
Description
No.
1
2
3
4
5
6
PCI-E 4.0 p1-x16 Low Profile Slot
2 RJ45 10G Ports
2 USB Ports
VGA Port
Redundant 1000W Titanium Level Power Supplies
UID Button
Dedicated BMC LAN Port
2
1
2
1
2
1
DescriptionDrive Bay(Node A-B)
4x 2.5” Hot-Swap SATA/SAS Drive Bays
3
0
~
Remove the plastic protective cover from the CPU
socket. Gently squeeze the grip tabs then pull the
cover off. Gr Tabsip
Locate four threaded fasteners (a, b, c, d) on the CPU socket.
Locate four PEEK nuts (A, B, C, D) and four rotating wires (1, 2, 3, 4) on
the heatsink as shown below.
Align nut A (next to the triangles and pin 1) on the heatsink with
threaded fastener "a" on the CPU socket. Also align nuts B, C, D
on the heatsink with threaded fasteners b, c, d on the CPU socket.
Gently place the heatsink on the CPU socket, making sure that
each nut is properly aligned with its corresponding threaded
fastener.
Press all four rotating wires outward to
latch the PHM onto the CPU socket.
With a t30-bit screwdriver, tighten all PEEK
nuts in the sequence of A, B, C, and D with
even pressure not greater than 12 lbf-in.
A
B
C
D
a
b
c
d
Rotating Wire
Rotating Wire
A
B
C
D
a
b
c
d
(a, b, c, d: Threaded Fasteners) CPU Socket Pin1
Threa asteded F nerCPU tSocke
Heatsink
A, B, C, D: Peek Nut
1, 2, 3, 4: Rotating Wire
a, b, c, d: Threaded Fastener
Peek Nut
(Unlatched) (latched)
Rotating Wire
B
D
Rotating Wire2
Rotating Wire 4
Rotating Wire 3
Peek Nut
A
C
Rotating Wire 1
CPU tSocke
Heatsink Installation
Description
No.
SXB1 : PCIe 4.0 p1-x8 Slot supported by CPU1 for Supermicro proprietary riser
card and six SATA connections (S-SATA0 - S-SATA5) supported by PCH
Intel PCH Powered I-SATA 3.0 Ports with support for SuperDOM (Disk on
Module) devices
JSD1 : SATA DOM (Disk-On-Module) Power Connector
JSD2 : SATA DOM (Disk-On-Module) Power Connector
P1-DIMMB1/P1-DIMMA1 slot
P1-DIMMD1/P1-DIMMC1 slot
P1-DIMMG1/P1-DIMMH1 slot
P1-DIMME1/P1-DIMMF1 slot
P2-DIMMB1/P2-DIMMA1 slot
P2-DIMMD1/P2-DIMMC1 slot
P2-DIMMG1/P2-DIMMH1 slot
P2-DIMME1/P2-DIMMF1 slot
SXB3 :
PCIe 4.0 p1-x16 Slot supported by CPU1 for the Supermicro proprietary riser card
SXB4 :
PCIe 4.0 p1-x16 Slot supported by CPU2 for the Supermicro proprietary riser card
SXB5 : PCIe 4.0 p1-x8 Slot supported by CPU1
LAN1, LAN2 : 10Gb Base-T Ethernet Ports
JBT1: CMOS Clear
CPU1 (Install CPU1 first)
CPU2
BAR CODE
PCH
LAN
CTRL
FAN4
BIOS
LICENSE
REV:1.01
X12DPT-PT46
DESIGNED IN USA
FAN3
JSD1
I-SATA4
CPLD1
JPTG1
JPAUX1
JPME2
JHS1
SXB6
I-SATA5
JSD2
LEDM1
LEDPWR
USB0/1
(
3.2 Gen 1
)
S-S A0~5AT
LAN2 LAN1
COM1
UID-LED
JUIDB1
BMC_LAN
VGA
CPU1 SXB6 PCI-E 4.0 X8
JRK1
JIPMB1
CPU1
CPU2
P2-DIMMC1
P2-DIMMD1
P2-DIMMA1
P2-DIMMB1
SXB1
CPU1 SXB1 PCI-E 4.0 X8
P2-DIMMF1
P2-DIMME1
P2-DIMMH1
P2-DIMMG1
SXB5
CPU1 SXB5 PCI-E 4.0 X8
P1-DIMMG1
P1-DIMMH1
P1-DIMME1
P1-DIMMF1
P1-DIMMB1
P1-DIMMA1
P1-DIMMD1
P1-DIMMC1
JBT1
JTPM1
JNCSI1
SXB3
CPU1 SXB3 PCI-E 4.0 X16
SXB4
CPU2 SXB4 PCI-E 4.0 X16
BT1
MAC CODE
IPMI CODE
1
7
3
2
6
11
9
10
12
13
15
16171819
14
8
5
4
Air shrouds concentrate airflow to maximize cooling efficiency
1. Screw the guide pins into the sled as shown below.
2. Position the air shrouds and drop them onto the
guide pins and into place.
Guid PIne s
Memory Support Front view & Interface Rear View
Nodes and Corresponding Hard Drives Air Shroud installation
Type
Ranks Per
DIMM and
Data Width
DIMM Capacity (GB) Speed (MT/s) and
Voltage
DRAM Density One DIMM per Channel
8Gb 16Gb 1.2V
RDIMM
SRx8 8GB 16GB
3200*
SRx4 16GB 32GB
DRx8 16GB 32GB
DRx4 32GB 64GB
RDIMM 3Ds (4R/8R) x4 2H-64GB
4H-128GB
2H-128GB
4H-256GB
LRDIMM QRx4 64GB 128GB
LRDIMM 3Ds (4R/8R) x4 4H-128GB 2H-128GB
4H-256GB
CP /DI s DI tsUs MM MM Slo
1 CPU & 1 DIMM A1
1 CP & 2 DI *Us MMs A1, E1
1 CP & 4 DI *Us MMs A1, , E1, G1C1
1 CP & 6 DI sUs MM A1, B1, , E1, F1, G1C1
2 CP & 8 DI *Us MMs A1, B1, , , E1, F1, G1, H1C1 D1
2 CP & 2 DI *Us MMs CP 1U1: A
CP 1U2: A
2 CP & 4 DI *Us MMs CP 1, E1U1: A
CP 1, E1U2: A
2 CP & 6 DI sUs MM CP 1, , E1, G1U1: A C1
CP 1, E1U2: A
2 CP & 8 DI *Us MMs CP 1, , E1, G1U1: A C1
CP 1, , E1, G1U2: A C1
2 CP & DI sUs 10 MM CP 1, B1, , E1, F1, G1U1: A C1
CP 1, , E1, G1U2: A C1
2 CP & DI *Us 12 MMs CP 1, B1, , E1, F1, G1U1: A C1
CP 1, B1, U2: A C1, E1, F1, G1
2 CP & DI sUs 14 MM CP 1, B1, , , E1, F1, G1, H1U1: A C1 D1
CP 1, B1, , E1, F1, G1U2: A C1
2 CP & DI *Us 16 MMs CP 1, B1, , , E1, F1, G1, H1U1: A C1 D1
CP 1, B1, , , E1, F1, G1, H1U2: A C1 D1
* o ed for ti l p o ncerec mmend op ma erf rma
DDR4 Mem ry rt 3r te ca cess o Suppo for d Gen In l Xe Son la e Probl ors
Memory Population for DDR4-only Configurations, 16 DIMM Slots
Product specificaties
Merk: | Supermicro |
Categorie: | Server |
Model: | SuperServer SYS-120TP-DC9TR |
Heb je hulp nodig?
Als je hulp nodig hebt met Supermicro SuperServer SYS-120TP-DC9TR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server Supermicro
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
Handleiding Server
- Server HP
- Server Sony
- Server Asus
- Server Medion
- Server Toshiba
- Server Abus
- Server Acer
- Server Acti
- Server Allnet
- Server Apc
- Server Axis
- Server Buffalo
- Server D-Link
- Server Dell
- Server Digi
- Server Digitus
- Server Dual Bay
- Server Eaton
- Server Elac
- Server EMC
- Server Fantec
- Server Flir
- Server Freecom
- Server Fujitsu
- Server GeoVision
- Server Gigabyte
- Server Hikvision
- Server Ibm
- Server In Win
- Server Iomega
- Server Kathrein
- Server LaCie
- Server Lenovo
- Server LevelOne
- Server Linksys
- Server Luxman
- Server Maxdata
- Server Megasat
- Server Monacor
- Server MSI
- Server Nec
- Server Netgear
- Server Provision ISR
- Server QNAP
- Server Quantum
- Server Revox
- Server Seagate
- Server Sitecom
- Server Sun
- Server Synology
- Server Technics
- Server Trendnet
- Server Veritas
- Server Western Digital
- Server ZyXEL
- Server Conceptronic
- Server Atlona
- Server SilverStone
- Server Intel
- Server SIIG
- Server Tripp Lite
- Server Valcom
- Server Cisco
- Server Matrox
- Server Asustor
- Server Gefen
- Server Planet
- Server Intellinet
- Server Silex
- Server G-Technology
- Server Lindy
- Server AVerMedia
- Server Black Box
- Server Blackmagic Design
- Server ATen
- Server Extron
- Server Areca
- Server AMX
- Server SEH
- Server StarTech.com
- Server HGST
- Server Sonnet
- Server TAIDEN
- Server Advantech
- Server Moxa
- Server Smart-AVI
- Server Kramer
- Server KanexPro
- Server Avocent
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server MvixUSA
- Server Promise Technology
- Server Raidsonic
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Middle Atlantic
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nieuwste handleidingen voor Server
18 December 2024
18 December 2024
9 December 2024
7 December 2024
3 December 2024
3 December 2024
3 December 2024
2 December 2024
1 December 2024
1 December 2024