Supermicro SuperServer F648G2-FC0PT+ Handleiding
Supermicro
Server
SuperServer F648G2-FC0PT+
Lees hieronder de 📖 handleiding in het Nederlandse voor Supermicro SuperServer F648G2-FC0PT+ (1 pagina's) in de categorie Server. Deze handleiding was nuttig voor 21 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/1
Board Layout
SuperServer F648G2-FC0+/FC0PT+ Quick Reference Guide
CPU Installation Front View & Interface
Heatsink Installation
1. Place the heatsink on top of the installed CPU.
2. Align the four screws to the socket.
3. Holding the heatsink in place, screw down as shown
(cross pattern, in order: A, C, B, D).
4. Note: Only use 6-8 lb/f of torque; otherwise, hand-tighten
each screw to avoid damaging the CPU.
Memory
Caution
SAFETY INFORMATION
IMPORTANT: See installation instructions and safety warning
before connecting system to power supply.
http://www.supermicro.com/about/policies/safety_information.cfm
WARNING:
To reduce risk of electric shock/damage to equipment,
disconnect power from server by disconnecting all power
cords from electrical outlets.
If any CPU socket empty, install protective plastic CPU cap
CAUTION:
Always be sure all power supplies for this system have
the same power output. If mixed power supplies are
installed, the system will not operate.
!
!
!
Rear View
Descrip iot n
No.
1
2
3
4
5
6
7
Full-height & half-length PCI-E Expansion Slot
UID Button
Power Button
VGA Port
GbE LAN1/LAN2 Ports
Dedicated LAN for IPMI
USB 0/1 Ports
Nodes and Corresponding Hard Drives
1 2
Descrip iot nNo.
1
2
Power Supply Module
Rear Fan
2
46 57 3 1
Pro ors and their Co g ory M escess rrespondin Mem odul
seludoM MMID gnidnopserroC#UPC
CPU 1 P1-
DIMMA1
P1-
DIMMB1
P1-
DIMMC1
P1-
DIMMD1
P1-
DIMMA2
P1-
DIMMB2
P1-
DIMMC2
P1-
DIMMD2
CPU2 P2-
DIMME1
P2-
DIMMF1
P2-
DIMMG1
P2-
DIMMH1
P2-
DIMME2
P2-
DIMMF2
P2-
DIMMG2
P2-
DIMMH2
Pro or and ory M e n for ti l P o ncecess Mem odul Popul ioat Op ma erf rma
Number of
CPUs+DIMMs
CPU and Memory Population Confi guration Table
(For memory to work properly, please follow the instructions below.)
1 CPU &
2 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1
1 CPU &
4 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
5~8 DIMMs
CPU1
P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + any pair of P1-DIMMA2/P1-
DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
4 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
6 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
8 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-
DIMMG1/P2-DIMMH1
2 CPUs &
9~16 DIMMs
CPU1 + CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-
DIMMG1/P2-DIMMH1 + any pair of P1, P2 DIMM slots
2 CPUs &
16 DIMMs
CPU1+ CPU2
P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-
DIMMG1/P2-DIMMH1, P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/
P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
F G N e s in the Ch is442B od Lo ioncat ass
Node 1
Controls eight 2.5" HDDs, A1-A8
Node 2
Controls eight 2.5" HDDs, B1-B8
http://www.supermicro.com MNL-1756-QRG
Screw #D
Screw #A
Screw #B
Screw #C
For more information go to :
http://www.supermicro.com/support
Align CPU to socket;
install CPU straight down
NOTE:
1. Do not bend pin inside socket.
2. Please contact Technical Support for additional information
about frequency optimized CPUs and specialized system
optimization.
!
13
14
15
16
17
18
19
20
21
22
23
24
25
JSD1 & JSD2: I-SATA4 & I-SATA5
Power Connector
I-SATA4~5: Support SMCI SuperDOM
T-SGPIO 1/2: Intel SATA SGPIO
I-SATA0~3: Internal SATA 3.0 Ports
P2-DIMME1 / P2-DIMME2
P2-DIMMF1 / P2-DIMMF2
CPU2 Socket
SXB2: CPU2 PCI-E p1-x32
Proprietary Slot
P2-DIMMH1 / P2-DIMMH2
P2-DIMMG1 / P2-DIMMG2
P1-DIMMD1 / P1-DIMMD2
P1-DIMMC1 / P1-DIMMC2
DescriptionNo.
1
2
3
4
5
6
7
8
9
10
11
12
SXB1: CPU1 Slot1 PCI-E 3.0 p1-x16
CPU1 Slot2 PCI-E 3.0 x8
CPU2 Slot3 PCI-E 3.0 x8
CPU1 Socket
PCH Slot4 PCIE-E 2.0 x4
JBT1: CMOS Clear
1G_bit LAN Ports 1/2 (X10DRFF-iG/CG)
10G_bit LAN Ports 1/2 (X10DRFF-iTG/CTG)
IPMI_LAN1: IPMI dedicated LAN Support
JTPM1: Trusted Platform Module Header
S-SATA 0~3: SATA 3.0 connectors
P1-DIMMB1 / P1-DIMMB2
P1-DIMMA1 / P1-DIMMA2
Proprietary Slot
DescriptionNo.
J23
JVRM1
JVRM2
JWD1
JPME2
UID_LED1
COM1
JSD2
JUIDB1
FAN7
FAN6
FAN1
FAN4
FAN5
FAN3
FAN2
FAN8
JBT1
I-SATA5
I-SATA3
I-SATA2
I-SATA1
I-SATA0
S-SATA2
S-SATA3
S-SATA0
S-SATA
1
I-SATA4
SXB1
HDD_LED1
LEDBMC
USB1
JPW1
HDD_PWR2
HDD_PWR1
JPW3
LEDS2
J22
BT1
S-SGPIO1
T-SGPIO2
JIPMB1
JP
REAR_FAN1
REAR_FAN2
SAS4-7
SAS0-3
PCH SLOT4 PCIE-E 2.0 X4
CPU2 SLOT3 PCI-E 3.0 X8
CPU1 SLOT2 PCI-E 3.0 X8
SXB1: CPU1 SLOT1 PCI-E X16 PROPRIETARY SLOT
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P1-DIMMA1
P2-DIMME1
P2-DIMME2
P2-DIMMF1
P2-DIMMF2
P2-DIMMG1
SXB2:CPU2 PCI-E X32 PROPRIETARY SLOT
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
JPW2
P1-DIMMC2
P1-DIMMC1
P1-DIMMD2
P1-DIMMD1
JNVI2C1
T-SGPIO1
CPU2
CPU1
X10DRFF-CG/CTG
JNVI2C2
BIOS
PCH
Battery
USB0
JSD1
JPS1
12
11
15
23 22 21
5 6 7
14
8
1920 18
25 24
1 2 3 4
10
17
9
16
13
JTPM1
mini-SAS HD Connectors:
SAS0-3: LSI SAS Port 0-3
SAS4-7: LSI SAS Port 4-7
Rev. 1.0a
Populating RDIMM/LRDIMM DDR4 Memory Modules
Type
Ranks
Per DIMM
and Data
Width
DIMM Capacity
(GB)
Speed (MT/s); Voltage (V); Slots per Channel (SPC) and
DIMMs per Channel (DPC)
2 Slots per Channel
1 DPC 2 DPC
E5-2600 V3 E5-2600 V4 E5-2600 V3 E5-2600 V4
4 GB 8 GB 1.2 V 1.2 V 1.2 V 1.2 V
RDIMM SRx4 8 GB 16 GB 2133 2400 1866 2133
RDIMM SRx8 4 GB 8 GB 2133 2400 1866 2133
RDIMM DRx8 8 GB 16 GB 2133 2400 1866 2133
RDIMM DRx4 16 GB 32 GB 2133 2400 1866 2133
LRDIMM QRx4 32 GB 64 GB 2133 2400 2133 2400
LRDIMM 3DS 8Rx4 64 GB 128 GB 2133 2400 2133 2400
Product specificaties
Merk: | Supermicro |
Categorie: | Server |
Model: | SuperServer F648G2-FC0PT+ |
Heb je hulp nodig?
Als je hulp nodig hebt met Supermicro SuperServer F648G2-FC0PT+ stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server Supermicro
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
17 November 2024
Handleiding Server
- Server HP
- Server Sony
- Server Asus
- Server Medion
- Server Toshiba
- Server Abus
- Server Acer
- Server Acti
- Server Allnet
- Server Apc
- Server Axis
- Server Buffalo
- Server D-Link
- Server Dell
- Server Digi
- Server Digitus
- Server Dual Bay
- Server Eaton
- Server Elac
- Server EMC
- Server Fantec
- Server Flir
- Server Freecom
- Server Fujitsu
- Server GeoVision
- Server Gigabyte
- Server Hikvision
- Server Ibm
- Server In Win
- Server Iomega
- Server Kathrein
- Server LaCie
- Server Lenovo
- Server LevelOne
- Server Linksys
- Server Luxman
- Server Maxdata
- Server Megasat
- Server Monacor
- Server Nec
- Server Netgear
- Server Provision ISR
- Server QNAP
- Server Quantum
- Server Revox
- Server Seagate
- Server Sitecom
- Server Sun
- Server Synology
- Server Technics
- Server Trendnet
- Server Veritas
- Server Western Digital
- Server ZyXEL
- Server Conceptronic
- Server Atlona
- Server SilverStone
- Server Intel
- Server SIIG
- Server Tripp Lite
- Server Valcom
- Server Cisco
- Server Matrox
- Server Asustor
- Server Gefen
- Server Planet
- Server Intellinet
- Server Silex
- Server G-Technology
- Server Lindy
- Server AVerMedia
- Server Black Box
- Server Blackmagic Design
- Server ATen
- Server Extron
- Server Areca
- Server AMX
- Server SEH
- Server StarTech.com
- Server HGST
- Server Sonnet
- Server TAIDEN
- Server Advantech
- Server Moxa
- Server Smart-AVI
- Server Kramer
- Server KanexPro
- Server Avocent
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server MvixUSA
- Server Promise Technology
- Server Raidsonic
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Middle Atlantic
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nieuwste handleidingen voor Server
9 December 2024
7 December 2024
3 December 2024
3 December 2024
3 December 2024
2 December 2024
1 December 2024
1 December 2024
23 November 2024
20 November 2024