Appendix D: Information for Lot 9 of ErP ( Ecod ) esign
This appendix designaddresses European Union E -(EU) co requirements for servers and storage
products only . All data and ratings within this appendix are in reference to the product(s) in this manual.
The below information corresponds to in Annex II of requirements laid down the commission regulation
2019/424.
3(1)(a): See section 1.1 of this manual for the product type.
3(1)(b): See title page and preface of this manual for trademark and manufacturer’s address.
3(1)(c): . See title page for product model number(s)
3(1)(d): See year . serial number on the physical system to determine the of manufacture
3(1)(e)*: PSU efficiency (Table) and power factor value (from 80 Plus report)
PSU Model #: PWS- - 2K20A 1R
Watts: 2200W
PSU efficiency
power factor
% of rated load
% % % % % 10 20 50 100 50
Single - )output (AC DC
. % 95. % 96. % 94. % 93 49 26 26 38 0.99
System (EUT) efficiency in idle state power
Representative Configurations
Measured Idle State Power (W)
Calculated Idle Power Allowance
(W)
High-end performance
configuration
569.1
1 013.9
Typical Configuration
N/A
N/A
Low-end performance
configuration
554.8
655.5
System (EUT) efficiency in active state power
Representative Configurations
Active state efficiency score
(Effserver)
Minimum active state
efficiency for 2 socket server
High-end performance
configuration
25.2
Typical Configuration
N/A
8
Low-end performance
configuration
17.4
3(1)(f)* :
3(1)(g)*:
3(1)(h)*:
3(1)(i)*: The following components, if included with the product in this manual, contain
additional idle power allowances: HDDs or SSDs, additional memory, and/or AOCs.
3(1)(j)* :
3(1)(k)*: is A2 The operating condition class
Dry bulb °Ctemp
Humidity range, non condensing-
Operating
condition
class
Allowable
range
Recom îž®
mended
range
Allowable range
Recommended range
Max dew
point (°C)
Maximum
rate of
change
(°
C/hr)
A1
15- 32
18 27-
–
12 and °C Dew P oint (DP)
8 % (RH) relative humidity to
17 80 ° C DP and % RH
–
9 °C DP to
15 °C DP and
60 % RH
17
5/20
A2
10 35-
18 27-
–
12 and to °C DP 8 % RH
21 °C DP % RHand 80
Same A1as
21
5/20
A3
5-40
18 27-
–
12 and to °C DP 8 % RH
24 °C DP % RHand 85
Same A1as
24
5/20
A4
5-45
18 27-
–
12 and to °C DP 8 % RH
24 °C DP % RHand 90
Same A1as
24
5/20
3(1)(l)*: The idle state power at the higher boundary temperature of the operating conditions
class is 569.1W
3(1)(m)*: The active state efficiency and performance: 25.2
3(1)(n): Secure data deletion description here. Chris/Michelle (SW) provide link----
3(1)(o): – List of recommended combinations of blade servers with chassis. N/A
3(1)( F619P3p) List of all current SKUs within this product family.---- SYS- -FT
3(3)(a): There is no use of cobalt in batteries in this product.
The indicative weight range of Neodymium in the HDD is if manufactured by 0.0
Western Digital, and is between 5- 25 grams if manufactured by Seagate.
3(3)(b): Disassembling Instructions
Illustrated System Disassembly Instructions
Please note: All the graphs in this disassembly instruction are for demonstration only. Components in the graphs may
not match exactly with the actual components.
Caution: Always power off system and unplug power cord(s) first before disassembling the
system!
SYS
SYS
SYS
SYSSYS-
-
-
-- 3-
3-
3-
3-3-FT
FT
FT
FTFT
F619P
F619P
F619P
F619PF619P
D ata storage devices
• Type of operation: Push the release button on the carrier. Swing the handle fully. Grasp
the handle and pull the drive carrier out of its bay.
• Type and number of fastenings to be unlocked: 1 latch and 4 Phillips screws.
• Tools required: Screwdriver with PH2 . bit


Product specificaties

Merk: Supermicro
Categorie: Server
Model: SuperServer F619P3-FT
Kleur van het product: Zwart
Gewicht: 68040 g
Breedte: 448 mm
Diepte: 737 mm
Hoogte: 177 mm
Gewicht verpakking: 90710 g
Breedte verpakking: 718.82 mm
Diepte verpakking: 381 mm
Hoogte verpakking: 1076.96 mm
LED-indicatoren: Fan fail, Fault, LAN, Power
Aan/uitschakelaar: Ja
Processorfamilie: Intel® Xeon® Scalable
VGA (D-Sub)poort(en): 1
Aantal Ethernet LAN (RJ-45)-poorten: 2
Netvoeding: 2200 W
Duurzaamheidscertificaten: RoHS
Type processor: Nee
Temperatuur bij opslag: -40 - 60 °C
Aantal ventilatoren: 8 ventilator(en)
Aantal poorten USB 3.2 Gen 1 (3.1 Gen 1) Type A: 2
Processor socket: LGA 3647 (Socket P)
Systeembus: 10.4 GT/s
Thermal Design Power (TDP): 165 W
Maximum intern geheugen: 3072 GB
On-board graphics adapter model: Aspeed AST2500
Luchtvochtigheid bij opslag: 5 - 95 procent
Type behuizing: Rack (4U)
80 PLUS certificatie: 80 PLUS Titanium
ECC: Ja
Chipset moederbord: Intel® C621
Type koeling: Actief
PCI Express x16 (Gen 3.x) slots: 2
Aantal 3.5" bays: 2
Ondersteunde opslagstationinterfaces: M.2, Serial ATA III
Soorten RAID: 0, 1,5, 10
PCI Express x8 (Gen 3.x) slots: 1
Compatibele processors: Intel® Xeon®
Aantal ondersteunde processoren: 2
Maximum UDIMM geheugen: 3072 GB
Aantal DIMM sloten: 12
Ondersteunende RDIMM klok snelheden: 2133,2400,2666,2933 MHz
Aantal storage drives ondersteund: 14
Opslagschijf afmetingen ondersteund: 3.5, M.2 "
Ondersteunde geheugen types: DDR4-SDRAM
AC-ingangsspanning: 100 - 240 V
AC-ingangsfrequentie: 50 - 60 Hz
Bedrijfstemperatuur (T-T): 10 - 35 °C
Relatieve vochtigheid in bedrijf (V-V): 8 - 90 procent
Ventilator diameter: 80 mm
Ondersteunde types opslag-drives: HDD & SSD
BIOS type: EEPROM
Grootte BIOS-geheugen: 128000 Mbit
PC gezondheids monitor: CPU, FAN, Temperature
Aantal M.2 (M) slots: 2
DC output stroom (+ 12 V): 100 A
IPMI LAN (RJ-45) port: Ja
Afmetingen voeding (BxDxH): 76 x 40 x 336 mm
DC uitgangsstroom (+ 5 V): 1 A