Supermicro SuperServer 2028TP-DECFR Handleiding
Supermicro
Server
SuperServer 2028TP-DECFR
Lees hieronder de 📖 handleiding in het Nederlandse voor Supermicro SuperServer 2028TP-DECFR (146 pagina's) in de categorie Server. Deze handleiding was nuttig voor 33 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/146

SUPERSERVER®
2028TP-DECR
2028TP-DECFR
2028TP-DECTR
USER’S MANUAL
Revision 1.0a

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0a
Release Date: September 14, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2015 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America

iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the SuperServer
2028TP-DECR/DECTR/DECFR. Installation and maintainance should be performed
by experienced technicians only.
The SuperServer 2028TP-DECR/DECTR/DECFR is a high-end server based on
the SC217HD+-R1K28B 2U rackmount chassis and the X10DRT-P/PIBF/PT dual
processor serverboards with two BPN-ADP-E1C-L-O-P controller cards for SAS/
SATA drives. All models have an IPMI LAN port and two serverboard nodes, each
with twelve hot-swap Hard Disk Drives (HDD) each per node.
Each of the various models of the SuperServer 2028TP-DECR/DECTR/DECFR
servers and their associated serverboards for each of their unique options are
listed in the table below:
SuperServer 2028TP-DECR/DECTR/DECFR Model Variations
Server
Model
X9DRT
Serverboard Infi niBand 10G Ethernet
2028TP-DECR X10DRT-P
2028TP-DECFR X10DRT-PIBF YES
2028TP-DECTR X10DRT-PT YES
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with
the server system and describes the main features of the X10DRT-P/PIBF/PT
serverboard and the SC217HD+-R1K28B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer
2028TP-DECR/DECTR/DECFR into a rack and check out the server confi guration
prior to powering up the system. If your server was ordered without processor and
memory components, this chapter will refer you to the appropriate sections of the
manual for their installation.

SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual
iv
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 2028TP-DECR/DECTR/DECFR.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X10DRT-P/PIBF/PT serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC217HD+-R1K28B server
chassis. You should follow the procedures given in this chapter when installing,
removing or reconfi guring SATA or peripheral drives and when replacing system
power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information
on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specifi cations

vi
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
SAS/SATA/NVMe ............................................................................................ 1-2
PCI Expansion Slots ....................................................................................... 1-2
Onboard Controllers/Ports .............................................................................. 1-3
Graphics Controller ......................................................................................... 1-3
Infi niBand ........................................................................................................ 1-3
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
SAS/SATA Subsystem ..................................................................................... 1-4
Front Control Panel ......................................................................................... 1-4
I/O Ports .......................................................................................................... 1-4
Cooling System ............................................................................................... 1-4
Air Shrouds ..................................................................................................... 1-4
Mounting Rails ................................................................................................ 1-4
1-4 Advanced Power Management ....................................................................... 1-5
Intel® Intelligent Power Node Manager (IPNM) ............................................. 1-5
Manageability Engine (ME) ............................................................................. 1-5
1-4 Contacting Supermicro .................................................................................... 1-7
1-5 2U Twin: System Notes ................................................................................... 1-8
Nodes .............................................................................................................. 1-8
System Power ................................................................................................. 1-8
SAS Backplane/Drives .................................................................................... 1-8
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-2
2-4 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual

viii
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions ..................................................................................................... 5-1
5-2 Connecting Cables .......................................................................................... 5-2
Connecting Data Cables ................................................................................. 5-2
5-3 Rear I/O Ports ................................................................................................. 5-3
5-4 Processor and Heatsink Installation................................................................ 5-4
Installing a Passive CPU Heatsink ................................................................. 5-7
Removing the Heatsink ................................................................................... 5-8
5-5 Installing Memory ............................................................................................ 5-9
Memory Support .............................................................................................. 5-9
5-6 Adding PCI Expansion Cards ........................................................................5-11
5-7 Serverboard Details ...................................................................................... 5-12
X10DRT-P/PIBF/PT Quick Reference ........................................................... 5-13
5-8 Connector Defi nitions .................................................................................... 5-14
5-9 Jumper Settings ............................................................................................ 5-17
Explanation of Jumpers ................................................................................ 5-17
5-10 Onboard Indicators ........................................................................................ 5-19
5-11 PCI-Express and SATA Connections ............................................................ 5-21
5-12 Installing Software ......................................................................................... 5-22
SuperDoctor 5 ............................................................................................... 5-23
5-13 Onboard Battery ............................................................................................ 5-25
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
Unpacking ....................................................................................................... 6-1
6-2 Removing the Power Cord .............................................................................. 6-2
6-3 Control Panel .................................................................................................. 6-2
6-4 Chassis Cover ................................................................................................. 6-3
6-5 Air Shrouds ..................................................................................................... 6-4
6-6 Checking the Airfl ow ....................................................................................... 6-5
6-7 System Fans ................................................................................................... 6-5
6-8 Removing and Installing the Backplane .......................................................... 6-7
Removing the Backplane ................................................................................ 6-7
Installing the Backplane .................................................................................. 6-9
6-9 Installing the Serverboard ............................................................................. 6-10
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual

Compatible Motherboards ............................................................................. 6-10
Permanent and Optional Standoffs ............................................................... 6-10
Installing an Daughter Card .......................................................................... 6-12
6-10 Adding an Expansion Card ........................................................................... 6-13
6-11 Drive Bay Installation/Removal ..................................................................... 6-14
Accessing the Drive Bays ............................................................................. 6-14
6-12 Power Supply ................................................................................................ 6-17
Power Supply Replacement .......................................................................... 6-17
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data ......................................................... 7-1
How to Start the Setup Utility ......................................................................... 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations...................................................................... 7-4
7-4 Event Logs .................................................................................................... 7-33
7-5 IPMI ............................................................................................................... 7-35
7-6 Security Settings ........................................................................................... 7-37
7-7 Boot Settings ................................................................................................. 7-38
Use this feature to confi gure Boot Settings: ............................................................ 7-38
7-8 Save & Exit ................................................................................................... 7-40
Appendix A BIOS Error Beep Codes
Appendix B System Specifi cations
ix
Table of Contents

x
Notes
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual

1-4
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual
SAS/SATA Subsystem
The 2028TP-DECR/DECTR/DECFR supports up to twenty-four (24) 2.5" hot-swap
SAS/SATA drives in trays (12 for each node). These drives are hot-swappable units
and are connected to an adapter card that provides power and control.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the drives.
Front Control Panel
SC217 models include four front panels on the handles of the chassis which control
each of the systems. Each control panel on the 2028TP-DECR/DECTR/DECFR
server provides you with system monitoring and control for one server node. LEDs
indicate system power, HDD activity, network activity, system overheat and power
supply failure. A main power ON/OFF button is also included.
I/O Ports
The SC217 chassis designed to be used in a 2U rackmount confi guration. The
SC217 chassis provides a low-profi le add-on card slot, a VGA port, two USB 3.0 ports
(additionally one internal USB header is included on the serverboard), two gigabit
(2028TP-DECR/2028TP-DECFR servers) or 10-gigabit (2028TP-DECTR server)
Ethernet ports, an IPMI Ethernet port and an Infi niBand® port (2028TP-DECFR
server only) per node.
Cooling System
The SC217 chassis accepts four system fans, which are powered from the
backplane.
Note: The fans in this system are NOT redundant, hot-plug.
Air Shrouds
The SC217 chassis includes two Mylar air shrouds that direct the airfl ow where
cooling is needed on each serverboard. Always use the air shroud included with
your chassis on each serverboard.
Mounting Rails
The SC217 includes a set of quick-release rails, and can be placed in a rack for
secure storage and use. To setup your rack, follow the step-by-step instructions
included in this manual.

1-6
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual
Figure 1-1. PCH C612 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
SPI
LAN3
RGRMII
Debug Card
FRONT PANEL
SYSTEM POWER
CTRL
FAN SPEED
PCI-E X1 G2
USB 2.0
PCH C612
6.0 Gb/S
LPC
1
0
SATA
5
4
RTL8211E-VB-CG
3
2
RJ45
Temp Sensor
EMC1402-1 *2 at diff SMBUS
TPM HEADER
USB 3.0
USB
AST2400
BMC
RMII/NCSI
VGA CONN
BMC Boot Flash
DDR3
5 PHASE
145W
1333/2133
1333/2133
DDR4
P1
P1
P0
VR12.5
P0
#2-1
DDR4
#1-4
#1-3
#1-2
#1-1
QPI
9.6G
CX3 IB
CPU1
DMI2
PCI-E X8 G3
#1-5
#1-6
PCI-E X8 G3
DMI2
CPU2
DDR-4 DDR-4
QPI
9.6G
5 PHASE
145W
VR12.5
#1
i350/
X540
LAN
PCI-E X8
SLOT1
SLOT2
PCI-E X8 G3
PCI-E X16 G3
PCI-E X16 G3
#1-7
#1-8
#2-2
#2-3
#2-4
#2-5
#2-6
#2-7
#2-8
6789
SXB2
COM1
Connector
#1
#2 #2
DMI2
#3 #3
SXB1
SPI
BIOS
SPI

2-2
SUPERSERVER 2028TP-DECR/DECTR/DECFR User's Manual
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suf cient air ow and ease in servicing.
• This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow any hot plug drives and power supply modules to cool before touching
them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.

Chapter 2: Server Installation
2-9
Figure 2-6. Installing into a Rack
Ball-Bearing
Shuttle
Standard Chassis Installation
Installing the Chassis into a Rack (Figure 2-6)
1. Con rm that the inner rails are properly installed on the chassis.
2. Con rm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Note: The gure below is for illustration purposes only. Always install servers to
the bottom of the rack rst.
Product specificaties
Merk: | Supermicro |
Categorie: | Server |
Model: | SuperServer 2028TP-DECFR |
Kleur van het product: | Zwart |
Gewicht: | 29900 g |
Breedte: | 438 mm |
Diepte: | 730 mm |
Hoogte: | 88 mm |
Gewicht verpakking: | 38600 g |
LED-indicatoren: | HDD, Network, Power |
Stroom: | 6 - 12 A |
Aan/uitschakelaar: | Ja |
Ethernet LAN: | Ja |
VGA (D-Sub)poort(en): | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 2 |
Netvoeding: | 1280 W |
Duurzaamheidscertificaten: | RoHS |
Plug and play: | Ja |
Type processor: | Nee |
Ethernet LAN, data-overdrachtsnelheden: | 10,100,1000 Mbit/s |
Temperatuur bij opslag: | -40 - 70 °C |
Aantal ventilatoren: | 4 ventilator(en) |
Aantal poorten USB 3.2 Gen 1 (3.1 Gen 1) Type A: | 2 |
Processor socket: | LGA 2011 (Socket R) |
Systeembus: | 9.6 GT/s |
PCI Express slots versie: | 3.0 |
Maximum intern geheugen: | 2000 GB |
On-board graphics adapter model: | Aspeed AST2400 |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Type behuizing: | Rack (2U) |
80 PLUS certificatie: | 80 PLUS Platinum |
Redundante voeding: | Ja |
ECC: | Ja |
Geheugen form factor: | 288-pin DIMM |
Ethernet interface type: | Fast Ethernet, Gigabit Ethernet |
Chipset moederbord: | Intel® C612 |
PCI Express x16 slots: | 1 |
Koperen ethernetbekabelingstechnologie: | 10BASE-T, 100BASE-TX, 1000BASE-T |
Ondersteunde opslagstationinterfaces: | Serial Attached SCSI (SAS)-3 |
Seriële poort(en): | 2 |
PCI Express x8 slots: | 1 |
Geheugen voltage: | 1.2 V |
LAN controller: | Intel I350-AM2, Realtek RTL8201N |
Geheugenbus: | 72 Bit |
Compatibele processors: | Intel® Xeon® |
Aantal ondersteunde processoren: | 2 |
Intel® Xeon series: | E5-2600 |
Maximum UDIMM geheugen: | 512 GB |
Aantal DIMM sloten: | 16 |
Ondersteunende RDIMM klok snelheden: | 1600,1866,2133,2400 MHz |
Ondersteunend DIMM module capaciteiten: | 4GB, 8GB, 16GB, 32GB, 64GB, 128MB |
Aantal storage drives ondersteund: | 12 |
Opslagcontroller: | LSI SAS3008 |
Opslagschijf afmetingen ondersteund: | 2.5 " |
Ondersteunde geheugen types: | DDR4-SDRAM |
Hot-swap HDD bays: | Ja |
AC-ingangsspanning: | 100 - 240 V |
AC-ingangsfrequentie: | 50 - 60 Hz |
Bedrijfstemperatuur (T-T): | 10 - 35 °C |
Relatieve vochtigheid in bedrijf (V-V): | 8 - 90 procent |
Aantal geïnstalleerde redundante voedingen: | 1 |
Type systeembus: | QuickPath Interconnect (QPI) |
Ventilator diameter: | 80 mm |
Ondersteunde types opslag-drives: | HDD |
BIOS type: | AMI |
Grootte BIOS-geheugen: | 16 Mbit |
ACPI version: | 1.0 / 2.0 |
Systeem Management BIOS (SMBIOS) versie: | 2.3 |
DC output stroom (+ 12 V): | 106.7 A |
Intelligent Platform Management Interface (IPMI) support: | Ja |
Geïntegreerde BMC met IPMI: | Ja |
IPMI LAN (RJ-45) port: | Ja |
DC uitgangsstroom (+ 5 V): | 4 A |
Maximale cache: | 55 MB |
Aantal SAS-poorten: | 12 |
BIOS-functies: | APM 1.2, PCI 2.2, Plug & Play, SMBIOS 2.3, UEFI |
Heb je hulp nodig?
Als je hulp nodig hebt met Supermicro SuperServer 2028TP-DECFR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server Supermicro

30 Januari 2025

8 Januari 2025

17 November 2024

17 November 2024

17 November 2024

17 November 2024

17 November 2024

17 November 2024

17 November 2024

17 November 2024
Handleiding Server
- Server HP
- Server Sony
- Server Asus
- Server Medion
- Server Toshiba
- Server Abus
- Server Acer
- Server Acti
- Server Allnet
- Server Apc
- Server Asrock
- Server Axis
- Server Buffalo
- Server D-Link
- Server Dell
- Server Digi
- Server Digitus
- Server Dual Bay
- Server Eaton
- Server Elac
- Server EMC
- Server Fantec
- Server Flir
- Server Freecom
- Server Fujitsu
- Server GeoVision
- Server Gigabyte
- Server Hikvision
- Server Ibm
- Server In Win
- Server Iomega
- Server Kathrein
- Server LaCie
- Server Lenovo
- Server LevelOne
- Server Linksys
- Server Luxman
- Server Maxdata
- Server Megasat
- Server Monacor
- Server MSI
- Server Nec
- Server Netgear
- Server Provision ISR
- Server QNAP
- Server Quantum
- Server Revox
- Server Seagate
- Server Sitecom
- Server Sun
- Server Synology
- Server Technics
- Server Trendnet
- Server Veritas
- Server Western Digital
- Server ZyXEL
- Server Conceptronic
- Server Atlona
- Server SilverStone
- Server Intel
- Server SIIG
- Server Tripp Lite
- Server Valcom
- Server Cisco
- Server Matrox
- Server Asustor
- Server Gefen
- Server Planet
- Server Intellinet
- Server Silex
- Server G-Technology
- Server Lindy
- Server AVerMedia
- Server Black Box
- Server Blackmagic Design
- Server ATen
- Server Extron
- Server Areca
- Server AMX
- Server SEH
- Server StarTech.com
- Server HGST
- Server Sonnet
- Server TAIDEN
- Server Advantech
- Server Moxa
- Server Smart-AVI
- Server Kramer
- Server KanexPro
- Server Avocent
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server MvixUSA
- Server Promise Technology
- Server Raidsonic
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Middle Atlantic
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nieuwste handleidingen voor Server

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

10 Maart 2025

20 Februari 2025