PF1 Instructions R2
Power Failure Alarm Cord, Model PF1
INSTRUCTIONS
SAVE THIS MANUAL FOR FUTURE REFERENCE
This ACCUCOLD power-failure line
cord has a built in power failure -
sensor with a loud audible n 80dB
alarm. It is intended for monitoring
essential 120 volt AC powered
cord-
connected appliances for
power failure events
, accidental
cord disconnection
and circuit
breaker failure. The loud signal
sounds for up to 90 minutes,
advising the user
to reconnect
power to the device.
Key C omponents of the Power Failure Alarm Cord
 15 Amp hospital grade - grounded three wire plug
 Alarm housing with rechargeable battery
 AC Power ON LED indicator
 Grounded three- wire 15 Amp connector
 Built-in switch that will silence the alarm when operated in the “alarm off” position
INSTALLATION
i. Attach the female connector to the plug of the appliance to be monitored.
ii. Plug the cord into any live 120 volt AC outlet.
Note: If the appliance plug is disconnected from the cord, the alarm will not sound. It will sound
only if power fails to reach the cord.
Summit Appliance Division, Felix Storch, Inc.
770 Garrison Ave ║Bronx, NY 10474 (718) 893 3900 Fax (844) 478 8799 ║Phone ║
║ ║www.summitappliance.com www.medicalrefrigerators.com
PF1
PF1 Instructions R2
Limited Warranty
SUMMIT products have a limited warr ranty pe iod of 1 year against defects in r mate ials and
wor e. kmanship from the date of purchas Accessory h e a w r items and sensors av limited ar anty
of 3 s. ser have a w rmonth Repair vices limited ar anty per fiod of 3 months against de ects in
mater wor pials and kmanshi . SUMMIT shall, at its option either repair or replace hard, ware
products that prov fe to be de ective, if a notice to fthat ef ect is received within the w rar anty
period. SUMMIT kma es other no w rar anties representations or any k everof ind whatso ,
e expressed or implied, xcept that of title, and all implied war arr any wanties including r anty of
merchantability fi fand tness or a pa pur ticular r pose are here y disclaimed.b
Summit, Div of Felix Storch, Inc. ‱ Bronx, NY 10474 ‱ Tel: 718 893 3900 - - ‱ Fax: - -844 478 8799
TESTING AND OPERATION
After the cord has been plugged into an AC outlet for 24 hours to obtain a full charge, simply disconnect
the cord from the AC outlet. The alarm should sound. Make certain that the switch is in the “alarm on”
position.
Printed in USA
SPECIFICATIONS
‱ Voltage and current: 120 VAC maximum, 15 amps maximum
‱ Frequency: 60 Hz
‱ For indoor use only
‱ Operating temperature range: 5oC to 40oC (41oF to 104oF)
PF1 Instructions R2
Cordon d’alarme pour panne de courant
INSTRUCTIONS
CONSERVER CE MANUEL POUR CONSULTATION ULTÉRIEURE
Ce cordon ACCUCOLD dispose d'un
capteur de panne de courant intégré
avec une alarme sonore 80dB. Il est
destinĂ© Ă  ĂȘtre utilisĂ© pour surveiller
des appareils essentiels alimentés
avec cordon de 120 volts CA pour les
événements de panne de courant,
déconnexion accidentelle du cordon,
et défaillance de disjoncteur. e signal L
fort sonne pour jusqu'Ă  90 minutes,
conseillant Ă  l'utilisateur de
reconnecter l’alimentation à
l'appareil.
P RINCIPAUX ÉLÉMENTS du CORDON d’ALARME pour PANNE de COURANT
 Bouchon Ă  trois fils de 15 a mpĂšres de qualitĂ© hospitaliĂšre, mis Ă  terre
 BoĂźtier d'alarme avec batterie rechargeable
 Indicateur LED d’alimentation CA allumĂ©e
 Connecteur Ă  trois- afils de 15 mpĂšres, mis Ă  terre
 Interrupteur intĂ©grĂ© qui fera taire l'alarme lorsqu'il est utilisĂ© dans la position « alarme Ă©teinte »
Summit Appliance Division, Felix Storch, Inc.
770 Garrison Ave ║Bronx, NY 10474 (718) 893 3900 Fax (844) 478 8799 ║TĂ©lĂ©phone ║
║ ║www.summitappliance.com www.medicalrefrigerators.com
INSTALLATION
i. Attacher le connecteur femelle Ă  la prise de l'appareil Ă  ĂȘtre surveillĂ©.
ii. active Branchez le cordon dans une prise de 120 volts CA.
Remarque: Si la fiche de l'appareil est déconnectée du cordon, l'alarme ne retentit pas. Elle
n’est audible que si le courant ne parvient pas à atteindre le cordon.
PF1


Product specificaties

Merk: Summit
Categorie: Niet gecategoriseerd
Model: Accucold PF1Kit

Heb je hulp nodig?

Als je hulp nodig hebt met Summit Accucold PF1Kit stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Summit

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd