Sloan G2 Optima Plus Handleiding

Sloan Niet gecategoriseerd G2 Optima Plus

Lees hieronder de 📖 handleiding in het Nederlandse voor Sloan G2 Optima Plus (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 4 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Code No. 0816452
Rev. 0a (05/03)
INSTALLATION INSTRUCTIONS
FOR RETROFIT AND COMPLETE
VALVE INSTALLATION
8100 Series Complete Flushometer Models
RESS Series Retrofit Conversion Kit Models
Made in the U.S.A.
LIMITED WARRANTY
Sloan Valve Company warrants its G2 Optima Flushometers to be made of first class materials, free from defects of material or workmanship underPlus
normal use and to perform the service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for
a period of five years (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any
part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under
this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who
purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
The Sloan G2 Optima Flushometer provides the ultimate in sanitaryPlus
protection and automatic operation. The Optima uses advanced infraredPlus
technology to detect a user's presence and initiate a flushing cycle once the
user steps away. The Optima is powered by four AA batteries which willPlus
provide up to three years of service (based on 4000 flushes per month).
RESS Optima models are used to convert existing Royal and Regal stylePlus
flushometers to sensor operation.
8100 series Optima valves are complete flushometer valves and idealPlus
for new installations.
When installing any Optima valve it is important that the flush modelPlus
matches the requirements of the plumbing fixture.
Optima Plus Water Closet Models can be furnished for the following:
1.6 gpf/6.0 Lpf For Low Consumption Bowls
2.4 gpf/9.0 Lpf For 9 Liter European Water Closets
3.5 gpf/13.2 Lpf For older Water Closets
Optima Plus Urinal Models can be furnished for the following:
0.5 gpf/1.9 Lpf For Wash Down Urinals
1.0 gpf/3.8 Lpf For Low Consumption Urinals
1.5 gpf/5.7 Lpf For older Siphon Jet Urinals
3.5 gpf/13.2 Lpf For older Blow Out Urinals
2¼” (57 mm) MIN.
Y”
C/L OF
WASTE
FINISHED WALL FINISHED
FLOOR
C/L OF
FIXTURE
1” I.P.S.
(25 mm DN)
SUPPLY
4¾”
(121 mm)
Reference for RESS-C Retrofit Reference for RESS-U Retrofit
11½”
(292 mm)
When installing the G2 Optima
Plus in a handicap stall:
Per the ADA Guidelines (section
604.9.4) it is recommended that
the grab bars be split or shifted to
the wide side of the stall. If grab
bars must be present over the
valve, use the Alternate ADA
Installation as shown below.
2¼” (57 mm) MIN.
16½”
(419 mm)
C/L OF WASTE
FINISHED
WALL FINISHED
FLOOR
C/L OF
FIXTURE
1” I.P.S.
(25 mm DN)
SUPPLY
4¾”
(121 mm)
11½”
(292 mm)
2¼” (57 mm) MIN.
16½”
(419 mm)
C/L OF
FIXTURE
FINISHED
FLOOR
FINISHED
WALL
4¾”
(121 mm)
8
8
8
8
81
1
1
1
18
8
8
8
80
0
0
0
0
1” I.P.S. (25 mm DN) SUPPLY
8
8
8
8
81
1
1
1
18
8
8
8
86
6
6
6
6
¾” I.P.S. (20 mm DN) SUPPLY
Lower water supply rough-in to 10” (254 mm) and mount grab
bar at the 36” (914 mm) maximum allowed height.
“X” Model 8115 & 8116 valves
are designed for installations
where the water supply is
roughed-in 24” - 27 (610
mm - 686 mm) above the top
of the water closet.
For new installations, Sloan
strongly recommends the use
of our Model 8111 which has
a shorter installation height.
2
Prior to installing the Sloan G2 Optima Flushometer, install the itemsPlus
listed below as illustrated in Figure 1. (New installations only.)
Closet or urinal fixture
Drain line
Water supply line
Important:
ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE
VOLUME OF WATER FOR EACH FIXTURE.
FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.
The Sloan G2 Optima is designed to operate with 15 to 100 PSI (104Plus
to 689 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO
THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult
fixture manufacturer for pressure requirements.
Most Low Consumption water closets (1.6 gallon/6 liter) require a minimum
flowing pressure of 25 psi (172 kPa).
Slotted screwdriver to adjust control stop.
Sloan A-50 “Super-Wrench™” or smooth jawed spud wrench for
couplings.
Trimpot adjustment screwdriver (supplied) to adjust range, if necessary.
Strap wrench (supplied) to install Optima to valve body.Plus
7/64” hex wrench (supplied) to secure Optima cover to base plate.Plus
IMPORTANT: The Strap Wrench provided with Optima Plus is a
convenience tool and is not to be used to remove or install the
Flushometer Couplings. Use Strap Wrench ONLY to install Optima
Plus Locking Ring.
Protect the chrome or special finish of this Flushometer. DO NOT
USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE. Also,
see "Care and Cleaning" section of this manual.
IMPORTANT: WITH THE EXCEPTION OF CONTROL STOP INLET, DO
NOT USE PIPE SEALANT OR PLUMBING GREASE ON ANY VALVE OR
OPTIMA PLUS COMPONENT!
10”
(254 mm)
2¼” (57 mm) MIN.
15”
(381 mm)
C/L OF WASTE
FINISHED
WALL FINISHED
FLOOR
18”
(457 mm)
36”
(914 mm)
Model “X” “Y”
8113 16” (406 mm) 21” (533 mm)
8115 24” (610 mm) 29” (737 mm)
8116 27” (686 mm) 32” (813 mm)
Use the Model 8113 when
toilet seat with covers are
being used.
Step 1 Install Control Stop (Figures 2 & 3)
Install the Sloan Bak-Chek Control Stop to the water supply line with the
outlet positioned as required.
For Sweat Solder applications, refer to the following instructions and
Figure 3:
1A. Measure distance from finished wall to centerline of fixture spud. Cut
water supply pipe 1¼" (32 mm) shorter than this measurement.
Chamfer O.D. and I.D. of water supply pipe.
1B. Slide Threaded Adapter onto water supply pipe until end of pipe rests
against shoulder of Adapter. Sweat Solder Adapter to water supply pipe.
1C. Determine length of Covering Tube by measuring distance from finished
wall to the first thread of Adapter (Dimension “X” in Illustration 1C
below). Cut Covering Tube to this length.
1D. Slide Covering Tube onto water supply pipe. Slide Wall Flange over
Covering Tube until it rests against the finished wall.
Install the Sloan Bak-Chek Control Stop to the water supply line with the
outlet positioned as required. Refer to Figure 2.
Step 2 Flush Out Supply Line (Figure 4)
Open Control Stop. Turn on water
supply to flush line of any debris or
sediment. Close Control Stop.
Step 3 Install Vacuum Breaker Flush Connection
(Figure 5)
Slide the Spud Coupling, Nylon Slip Gasket, Rubber Gasket and Spud
Flange over the Vacuum Breaker Tube. Insert Vacuum Breaker Tube into
fixture spud. Hand tighten Spud Coupling onto fixture spud.
If cutting Vacuum Breaker Tube to size, note that Critical Line (C/L) on
Vacuum Breaker must typically be 6” (152 mm) above fixture. Consult Code
for details.
Step 4 Install Flushometer (Figures 6 and 7)
SLOAN ADJUSTABLE TAILPIECE (Figure 6)
The Sloan Adjustable Tailpiece
compensates for "off-center" roughing-in
on the job. Maximum adjustment is ½"
(13 mm) IN or ½" (13 mm) OUT from the
standard 4¾" (121 mm) (centerline of
Flushometer to centerline of Control Stop).
IMPORTANT: WITH THE EXCEPTION
OF CONTROL STOP INLET, DO NOT
USE PIPE SEALANT OR PLUMBING
GREASE ON ANY VALVE OR OPTIMA
PLUS COMPONENT!
Refer to Figure 7
Insert Adjustable Tailpiece into Control Stop. Wet O-ring Seal with water to
lubricate. Secure by hand tightening Tailpiece Coupling.
Align Flushometer body on top of Vacuum Breaker Flush Connection and
secure by hand tightening Vacuum Breaker Coupling.
Align Flushometer body and securely tighten Tailpiece Coupling, Vacuum
Breaker Coupling and Spud Coupling, respectively.
I
I
I
I
Im
m
m
m
mp
p
p
p
po
o
o
o
or
r
r
r
rt
t
t
t
ta
a
a
a
an
n
n
n
nt
t
t
t
t N
N
N
N
No
o
o
o
ot
t
t
t
te
e
e
e
e:
:
:
:
: Use a smooth jawed wrench to secure all couplings. This will
eliminate damage to chrome or special finish that normally occurs when slip-
joint pliers, pipe wrenches or other "toothed" tools are used.
3
WATER
SUPPLY PIPE
Figure 3
FINISHED WALL
C/L OF FIXTURE SPUD
1¼” (32 mm)
ADAPTER
COVERING TUBE
WALL FLANGE
“X”
Figure 4
G-44 FRICTION RING
Figure 7 C/L
SUPPLY
ADJUSTABLE
TAILPIECE
C/L
FIXTURE
CONTROL STOPO-RING
TAILPIECE COUPLING
VACUUM BREAKER
FLUSH CONNECTION
VACUUM BREAKER
COUPLING
FLUSHOMETER BODY
SPUD COUPLING
Figure 6 4¼” MIN.
(108 mm)
5¼” MAX.
(133 mm)
Figure 5
8110/8111/8115/811
8110/8111/8115/811
8110/8111/8115/811
8110/8111/8115/8118110/8111/8115/8116
6
6
66 8180
8180
8180
81808180 8186
8186
8186
81868186
VACUUM
BREAKER TUBE
SPUD
COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
VACUUM
BREAKER TUBE
SPUD
COUPLING
NYLON SLIP
GASKET
RUBBER
GASKET
SPUD FLANGE
4-3/4"
(121 mm)
SUPPLY
FLANGE
BAK-CHEK®CONTROL STOP
IRON PIPE NIPPLE OR COPPER PIPE WITH
SWEAT SOLDER ADAPTER
SETSCREW
COVERING TUBE
Figure 2


Product specificaties

Merk: Sloan
Categorie: Niet gecategoriseerd
Model: G2 Optima Plus

Heb je hulp nodig?

Als je hulp nodig hebt met Sloan G2 Optima Plus stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Sloan

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd