Saxon 8710P3 Handleiding
Saxon
Weerstation
8710P3
Lees hieronder de π handleiding in het Nederlandse voor Saxon 8710P3 (4 pagina's) in de categorie Weerstation. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/4
1
Operation Instruction
β
. Main Functions:
1. Weather forecast for 5 states: sunny, semi-sunny, cloudy, rainy, cloudburst.
2. Time display (displaying month, date, day, hour, minute, second)
3. Indication of the trend of air pressure/temperature/humidity
4. Indication of the comfort index: dry, comfortable and wet.
5. Air pressure record of 12-hour
6. Units of air pressure for choice: mb/hpa, or inHg.
7. Calculation of sunrise and sunset time of 160 cities in Europe.
8. The indoor/outdoor temperature/humidity and Max/Min record.
9. Temperature alert.
10. Dual alarms.
11. Sunrise and Sunset display
12. Time display format for choice:12/24 hour.
13. Temperature display format for choice: β/β.
14. Moon phase calculated.
β
‘. Power-On or Reset
1. When Power-On or reset, LCD full displays for 3 seconds, and after a βBeepβ it begins testing indoor temperature, humidity and air
pressure.
2. The calendar defaults 0:00:00 January 1, 2007
3. Alarm defaults 0:00.
4. The weather icon defaults semi-sunny.
β
’. Instruction of operating the KEYS
1. Key functions
Twelve functional keys: DOWN,UP, ALARM,TIME SET,LOCATION,SNOOZE,HISTORY,β²,
βΌ,ALERT,MAX/MIN,CHANNEL.
TIME SET
ALARM
UP
DOWN
SNOOZE
LOCATI
ON
Standard mode
Click
-----
Time
displaying /
alarm1/
Alarm2
------
Alarm on/off
-----
----
Hold
Enter into
time setting
Enter into
alarm setting
-----
-------
-----
Enter 160
cities set
Time set
Click
Confirm
the setting
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Alarm set
Click
-----
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
City set
Click
-----
-----
One step
forward
One step
backward
-----
Confirm
the setting
Hold
-----
-----
8steps/seco
nd forward
8steps/second
backward
-----
-----
Channel
Alert
β²
βΌ
MAX/MIN
HISTORY
Standard
mode
Click
Exit RF
receiving
state/shift
channel
All the
MAX/MIN
temperature alert
on/off
Shift Hpa/inHg
Β°C/Β°F switchable
Showing the
Max value
----
Function
Operation
Function
Operation
2
Hold
Enter into
RF
registering
state
Enter into
temperature alert
setting
-----
-----
Enter into
snooze state
Enter 160
cities set
Temperature set
Click
Choose the
channel
need to be
set
Confirm the
setting
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8 steps/second
forward
8steps/second
backward
-----
-----
Height
set
Click
-----
-----
One step
forward
One step
backward
-----
-----
Hold
-----
-----
8steps/second
forward
8steps/second
backward
-----
-----
TIME SET Key:
Hold βTIME SETβ key for 2 seconds to enter into time setting mode, the sections being set will flash in the frequency of 1 Hz/second,
press βUPβ or βDOWNβto choose the value needed then press βTIME SETβ key to confirm the setting.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
ALARM Key
Click βAlarmβ key to display alarm time, press once to display AL1; twice for Al2; thrice to return to standard state. Hold βAlarmβ key
for 2 seconds to enter alarm setting, the sequence: AL1/ AL2ο Hourο Minuteο Exit.
It will return to standard mode automatically, if there is no operation for more than 7 seconds.
UP Key
Under setting mode, click βUPβ Key to adjust one step (forward), holding the βUPβ Key for 2 seconds to enter speedy adjusting mode (8
steps/seconds).
DOWN Key
Under setting mode, click βDOWNβ Key to adjust one step (backward), holding the βDOWNβ Key for 2 seconds to enter speedy
adjusting mode (8 steps/seconds).
Under standard mode, Click βDOWNβ Key to turn alarm on/off, the setting sequence: AL1 on/ AL2 off ο AL2 on/ AL1 off ο AL1,
AL2 on ο AL1, AL2 off.
SNOOZE Key
When the alarm is ringing, click βSNOOZEβ key to pause the alarm, and enter 5 minutes of snooze function.
LOCATION Key
Under standard mode, hold the βLOCATIONβ key for 2 seconds to enter city setting.
Under city setting state, hold βUPβ or βDOWNβ key to choose the city, and then click βLOCATIONβ key to confirm the setting and exit
the state.
CHANNEL Key
Under standard mode, click βChannelβ key to shift RF channel, CH1ο CH2 ο CH3ο displaying circularly.
Under standard mode, hold βChannelβ Key for 2 seconds to clean out RF registering state, temperature displays and MAX/MIN value.
Under Alert setting channel state, choose the needed setting channel..
MAX/MIN Key
Click βMax/Minβ key to display MAX value of indoor/outdoor temperature, humidity for 5 seconds. Click once again to display the
MIN values for 5 seconds, click again to return to standard mode.
When it displays the Max or Min values, hold Max/Min key for 2 seconds to clear out the memory of the Max/Min values, then return to
normal standard state.
ALERT Key
Under standard mode, click Alert key to turn temperature alert on/off.
Under standard mode, hold Alert key for 2 seconds, it will enter temperature alert setting.
3
Under temperature alert setting mode, click Alert key to confirm the setting items, the sequence: channelο setting the Maxο setting the
Min.
β²Key
Under standard mode, click β² to choose the unit of air pressure: Hpa/Mb or inHg.
Under setting mode, click once to go forward one step/second, hold for 2 seconds to go forward 8 steps/second.
βΌKey
Under standard mode, click to choose the unit of temperature between Β°C/Β°F.
Under setting mode, click to go backward one step, hold for 2 seconds to go backward 8 steps/second.
HISTORY Key
Under standard mode, clicking to check the air pressure record of past 12 hours.
RF Receiving Mode
1. After power-on and finishing testing temperature, humidity and air pressure, it enters RCC receiving state for 3 minutes. Under
standard mode, hold CH key for 3 seconds to enter RF receiving mode. If there is no new effective signal from sensors in 60 minutes,
the outdoor temperature of that CH will display β----β.
2. The outdoor temperature will display valid value of that CH from β----β when the main unit detects and receives the correct signal
from that CH again.
3. Hold βCHANNELβ, it displays CH1-->CH2-->CH3-->auto recycling (5 seconds a shift).
TIME MODE
1. The default time after power-on is 2007.1.1, 0:00:00, the range of perpetual calendar 2000-2099.
2. Under standard mode, hold βTIME SETβ key for 2 seconds to enter time setting mode.
3. Under setting mode, press βUPβ or βDOWNβ key to adjust the data of items to be set, click βTIME SETβ to confirm the data.
4. Under setting mode, the items being set will flash in the frequency of 2Hz/second, the setting sequence: yearο monthο dateο
languageο 12/24HRο hourο minuteο time zoneο exit.
5. If there is no valid operation on the key after 7 seconds, it will exist the setting mode, but the items set will be kept. The valid keys
include βTIME SETβ, βUPβ, βDOWNβ.
ALARM ALERT MODE
1. Under standard mode, click βALARMβ to view the Alarm time, the sequence: AL1, AL2, Normal.
2. Under standard mode, click βUPβ key to switch the alarm ON/OFF, the sequence: AL1 ON, AL2 OFFο AL1 OFF, AL2 ONο AL1
ON, AL2 ONο AL1 OFF, AL2 OFF.
3. Under ALARM time displaying mode, hold βALARMβ key for 2 seconds to enter ALARM setting mode.The setting sequence:
AL1/AL2ο hour settingο minute settingο exist setting mode.
4. During the setting, click βUPβ or βDOWNβ key to adjust the items to be set, and click βALARMβ key to confirm the items.
5. If there is no effective operation on the key after 8 seconds, it will exit the setting mode, but the items set will be kept. The effective
keys include βALARMβ, βUPβ, βDOWNβ.
6. Alarm ringing for 2 minutes totally ,and Alarming format::
(1) 0~10 seconds: one Beep/second;
(2) 10~20 seconds: two Beeps/second;
(3) 20~30 seconds, three Beeps/second;
(4) After 30 seconds, Beeping continuously.
The alarm is switched on after set.
CITY SETTING
1. Under standard mode, hold βLOCATIONβ key for 2 seconds to enter location setting and choose the city you stay (there are 160
European cities for selection).
2. Click βUPβ or βDOWNβ to choose, and click βLOCATIONβ key to confirm.
SUNRISE / SUNSET , MOON PHASE AND TIDE
1. The unit will calculate automatically the time of sunrise/sunset of the city everyday after the city is selected.
2. It will calculate moon phase and tide ebb/ flux every day according to the calendar. There are 8 states of moon phase and 3
step(H,M,L) of tide in all
THERMOMETER AND HYGROMETER
1. The indoor temperature range: 0Β°C-50Β°C (32Β°F-122Β°F), and the outdoor temperature range: -50Β°C-70Β°C (-58Β°F-158Β°F).
2. Humidity range: 20%-95%.
AIR PRESSURE AND WEATHER REPORT MODE
Product specificaties
Merk: | Saxon |
Categorie: | Weerstation |
Model: | 8710P3 |
Heb je hulp nodig?
Als je hulp nodig hebt met Saxon 8710P3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Saxon
26 September 2023
26 September 2023
30 Oktober 2022
Handleiding Weerstation
- Weerstation Braun
- Weerstation Daewoo
- Weerstation Honeywell
- Weerstation Ade
- Weerstation Adler
- Weerstation Alecto
- Weerstation Ascot
- Weerstation Auriol
- Weerstation Balance
- Weerstation Balance Meteo
- Weerstation Beurer
- Weerstation Blaupunkt
- Weerstation Brandson
- Weerstation Bresser
- Weerstation Brigmton
- Weerstation Daikin
- Weerstation Davis
- Weerstation Denver
- Weerstation Dexford
- Weerstation Digi-tech
- Weerstation DMV Electronics
- Weerstation Durabase
- Weerstation Ea2 LABS
- Weerstation Elgato
- Weerstation Elro
- Weerstation ELV
- Weerstation EQ-3
- Weerstation Eurochron
- Weerstation Extech
- Weerstation Fluke
- Weerstation Garni
- Weerstation Gira
- Weerstation GlobalTronics
- Weerstation Guardo
- Weerstation Hama
- Weerstation Hesdo
- Weerstation HomeMatic
- Weerstation Hyundai
- Weerstation Inovalley
- Weerstation Irox
- Weerstation IT
- Weerstation Konig
- Weerstation Krontaler
- Weerstation La Crosse
- Weerstation Lexibook
- Weerstation Livoo
- Weerstation Lowrance
- Weerstation Marquant
- Weerstation Meade
- Weerstation Mebus
- Weerstation Medisana
- Weerstation Minox
- Weerstation Muse
- Weerstation Nasa
- Weerstation National Geographic
- Weerstation Nedis
- Weerstation Netatmo
- Weerstation Nor-tec
- Weerstation Paget Trading
- Weerstation PCE Instruments
- Weerstation Perel
- Weerstation Prestigio
- Weerstation Profile
- Weerstation Pyle
- Weerstation Renkforce
- Weerstation Rocktrail
- Weerstation Saphir
- Weerstation Sempre
- Weerstation Sencor
- Weerstation Soehnle
- Weerstation Solar
- Weerstation Steinberg
- Weerstation Tanita
- Weerstation Taylor
- Weerstation Techno Line
- Weerstation Technoline
- Weerstation Telefunken
- Weerstation TFA
- Weerstation Theben
- Weerstation Thierry Mugler
- Weerstation Thomson
- Weerstation Unitec
- Weerstation UPM
- Weerstation Velleman
- Weerstation Ventus
- Weerstation Vitek
- Weerstation Weinberger
- Weerstation Xeecom ApS
- Weerstation Ytora
- Weerstation Jacob Jensen
- Weerstation Jung
- Weerstation Optex
- Weerstation Oregon Scientific
- Weerstation Orion
- Weerstation Otio
- Weerstation Clas Ohlson
- Weerstation Camry
- Weerstation Clatronic
- Weerstation ECG
- Weerstation OBH Nordica
- Weerstation GoGEN
- Weerstation Goddess
- Weerstation EMOS
- Weerstation Cotech
- Weerstation Levenhuk
- Weerstation Cresta
- Weerstation Avidsen
- Weerstation Majestic
- Weerstation Prologue
- Weerstation Trevi
- Weerstation Day
- Weerstation Kemot
- Weerstation Chacon
- Weerstation AcuRite
- Weerstation Buienradar
- Weerstation La Crosse Technology
- Weerstation EVE
- Weerstation Waldbeck
- Weerstation EQ3
- Weerstation Homematic IP
- Weerstation EMOS SELECT
- Weerstation Uzoli
- Weerstation TFA Dostmann
- Weerstation Greisinger
- Weerstation Ease Electronicz
- Weerstation Rebel
- Weerstation PeakTech
- Weerstation YONO
- Weerstation JDC
- Weerstation Greenure
- Weerstation Chauvin Arnoux
- Weerstation ChiliTec
- Weerstation Global Water
- Weerstation Marathon
- Weerstation Gewiss
- Weerstation Browin
- Weerstation ClimeMET
- Weerstation Baldr
- Weerstation Setti+
- Weerstation Bearware
Nieuwste handleidingen voor Weerstation
15 December 2024
15 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024