Salus RXBC605 Handleiding

Salus Receiver RXBC605

Lees hieronder de 📖 handleiding in het Nederlandse voor Salus RXBC605 (2 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 80 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
886MHz
Instruction Manual
SALES
Email: sales@salus-tech.com
Tel: 01226 323961
TECHNICAL
Email: tech@salus-tech.com
Tel: 01226 323961
SALUS Controls plc, SALUS House,
Dodworth Business Park South,
Whinby Road, Dodworth, Barnsley S75 3SP
www.salus-controls.com
PRODUCT COMPLIANCE
This product complies with the essential
requirements of the following EC Directives:
Electro-Magnetic Compatibility
directive 2004/108/EC
Low Voltage Directive 2006/95/EEC
EC Marking Directive 93/68/EEC
R&TTE Directive 99/5/EC
SAFETY INFORMATION
These instructions are applicable to the
SALUS Controls model stated on the front
cover of this manual only, and must not
be used with any other make or model.
These instructions are intended to apply
in the United Kingdom only, and should
be followed along with any other statutory
obligations. This accessory must be fitted
by a Competent person, and installation
must comply with the guidance provided in
the current editions of BS7671 (IEE Wiring
Regulations) and PartP’ of the Building
Regulations. Failure to comply with the
requirements of these publications could
lead to prosecution.
Always isolate the AC Mains supply before
opening or removing the unit from the
boiler.
Please leave these instructions with the end
user where they should be kept in a safe
place for future reference.
INSTALLING THE RF
BOILER CONTROL
1. Remove the front panel from the boiler.
2. Pull out the mechanical timer.
3. Do not remove boiler loop.
4. Connect the electrical plug.
5. Push fit boiler control into housing.
6. Replace the front panel ensuring a
good seal is made.
7. Power up the boiler and check the
correct operation.
RF Boiler Control
LED indicator for learning / output status
Recessed button for ID learning
Max. ambient temperature 55°C
Transmitter link via radio frequency
Current rating 5A (resistive) @ 230V AC
Connections:
1 - Neutral input
2 - Live input
3 - Common input
4 - Normally open output
BOILER CONTROL
WIRING TERMINALS
Terminal Identifier Description
1 N Neutral
2 L Live feed (230V AC)
3 COM Common Terminal
(Volt free)
4 N.O. Normally Open
TYPICAL WIRING
INSTALLATION
Boiler Control Boiler
BOILER CONTROL
MANUAL OVERRIDE
The AUTO/MANUAL switch allows you
to turn on the Boiler Control manually if
required.
When the switch on the Boiler Control is
in the AUTO (normal) position, the Boiler
Control will automatically receive the RF
signal from the transmitter and control the
boiler based on the programming of the
transmitter.
The user can also move the switch to
the MANUAL position; when in this
mode, the boiler will be always turned
on and the LED indicator will also be lit
constantly. The manual mode is only to be
used as a temporary control if problems
develop with the communication from the
thermostat.
MANUAL AUTO
SYNCHRONISING THE
BOILER CONTROL
Boiler Control RF Sync mode - Press and
hold “SYNC” button on the boiler control for
a few seconds to enter ID learning mode,
LED flashes. - Until ID is captured and
memorized into EEPROM (within max 12
minutes), LED stops flashing and stays ON
(relay close) or OFF (relay open) if ID is never
captured, LED will keep flashing to alert user
to re-sync, until 12 minutes timeout.
PLEASE REFER TO THE THERMOSTAT
MANUAL FOR PAIRING OPTIONS
* For full instructions on
thermostat pairing see:
RT505TX Manual - Page 13
ST325TX Manual - Page 15
RT305TX Manual - Page 9
ST625TX Manual - Page 11
PRODUCT SPECIFICATION
Model: RXBC605
Type: RF Boiler Control
Boiler Control
Power Source: 230V AC / 50Hz
Radio Frequency: 868 MHz
Switching Voltage: 0-230V AC / 50Hz
Switching Current: 5A resistive,
1A inductive
When the thermostat is operating in
NORMAL mode, if the Boiler Control has
not received a signal from the transmitter
after 1 hour, the Boiler Control will turn off
the boiler, and the LED indicator will flash
constantly (two times every second). Once
the Boiler Control receives a valid ON or
OFF signal, the Boiler Control will control
the heating system accordingly.
SYNC Button
RXBC605


Product specificaties

Merk: Salus
Categorie: Receiver
Model: RXBC605

Heb je hulp nodig?

Als je hulp nodig hebt met Salus RXBC605 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Salus

Salus

Salus RXBC605 Handleiding

22 Februari 2023

Handleiding Receiver

Nieuwste handleidingen voor Receiver