Salus MP100A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Salus MP100A (16 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 215 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Energy Saving A Rated Circulating Pump
Models: MP100A, MP200A & MP280A
O P E R AT I O N M A N UAL
Product compliance & safety information
These instructions are applicable to the SALUS Controls model stated on the front cover of this
manual only, and must not be used with any other make or model.
This accessory must be tted by a Competent person, and installation must comply with the guidance
provided in the current IEE Wiring Regulations and any relevant Building Regulations. Failure to
comply with the requirements of these publications could lead to prosecution.
Please leave these instructions with the end user where they should be kept in a safe
place for future reference.
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
02 Energy Saving A Rated Circulating Pump
04 Energy Saving A Rated Circulating Pump
Notes
01. Read the installation manual carefully before installation and use.
02. SALUS will not be liable for any personal injury, pump damage and other property damage due to
failure to comply with contents specied in safety warning signs.
03. The installers and operators must comply with all relevant local safety regulations.
04. The user must conrm that only qualied personnel with professional certication and prociency of this
manual is allowed to install and maintain this product.
05. The pump must not be installed in a place that is damp or may be splashed by water.
06. For convenient access of maintaince, a shut-o valve shall be installed on each side of the pump.
07. The power supply of the pump shall be cut o before installation and maintainace.
08. For domestic hot water, copper or stainless steel pump body shall be used.
09. Heat supply pipelines shall not be frequently lled with non-softened water so as to avoid increasing calcium
in the circulating water inside the pipeline, which may thus block the impeller.
10. Do not start the pump without liquid.
11. Not suitable for drinking water.
12. The liquid may be high temperature and high-pressure; therefore, the liquid in the system must be
completely drained or the shut-o valves on both sides, closed before moving and dismantling the
pump to prevent burning.
13. If removing the vent plug, high temperature and high-pressure liquid will be overew. Therefore,
it is necessary to guarantee that the outow liquid will not cause personal injury or damage other parts.
14. Ventilation must be ensured in summer or high ambient temperature period to avoid condensation
that may cause electrical malfunctions.
15. In winter, the pump system does not work or when the ambient temperature drops below 0 , ℃
liquid in the system shall be completely drained so as to avoid frost cracking of pump body.
16. If the pump is left unused for a long time, please close the pipe valve in the inlet and outlet of
the pump and cut o the power supply.


Product specificaties

Merk: Salus
Categorie: Niet gecategoriseerd
Model: MP100A

Heb je hulp nodig?

Als je hulp nodig hebt met Salus MP100A stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Salus

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd