Rotel A10MKII Handleiding

Rotel Receiver A10MKII

Lees hieronder de 📖 handleiding in het Nederlandse voor Rotel A10MKII (12 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
A10MKII
Stereo Integrated Amplifier
Amplificateur Stéréo Intégré
Stereo-Vollverstärker
Amplificatore Integrato Estereofonico
Geïntegreerde stereoversterker
Amplificatore integrato stereo
Integrerad Stereoförstärkare
Интегрированный стерео усилитель
Owner’s Manual
Manuel d’utilisation
Bedienungsanleitung
Manual de Instrucciones
Gebruikershandleiding
Manuale di istruzioni
Instruktionsbok
Инструкция пользователя
2A10MKII Stereo Integrated Amplifier
The apparatus should be used in non tropical
climate.
The ventilation should not be impeded by
covering the ventilation openings with items,
such as newspapers, table-cloths, curtains, etc.
No naked flame sources, such as lighted
candles, should be placed on the apparatus.
Touching uninsulated terminals or wiring may
result in an unpleasant sensation.
WARNING: There are no user serviceable parts
inside. Refer all servicing to qualified service
personnel.
WARNING: To reduce the risk of fire or electric
shock, do not expose the unit to moisture or
water. Do not expose the unit to dripping or
splashing. Do not place objects filled with
liquids, such as vases, on the unit. Do not allow
foreign objects to get into the enclosure. If the
unit is exposed to moisture, or a foreign object
gets into the enclosure, immediately disconnect
the power cord from the wall. Take the unit to
a qualified service person for inspection and
necessary repairs.
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install
in accordance with the manufacturers
instructions.
Do not install near any heat sources such
as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce
heat.
Do not defeat the safety purpose of the
polarized or grounding-type plug. A polarized
plug has two blades with one wider than the
other. A grounding type plug has two blades
and a third grounding prong. The wide blade or
the third prong are provided for your safety. If
the provided plug does not fit into your outlet,
consult an electrician for replacement of the
obsolete outlet.
Protect the power cord from being walked on
or pinched particularly at plugs, convenience
receptacles, and the point where they exit from
the apparatus.
Only use attachments/accessories specified
by the manufacturer.
Use only with the cart, stand, tripod, bracket, or
table specified by the manufacturer,
or sold with the apparatus. When
a cart is used, use with caution
when moving the cart/apparatus
combination to avoid injury from tip-over.
Unplug this apparatus during lightning storms
or when unused for long periods of time.
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power
supply cord or plug is damaged, liquid has
been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to
rain or moisture, does not operate normally, or
has been dropped.
Rotel products are designed to
comply with international directives
on the Restriction of Hazardous
Substances (RoHS) in electrical
and electronic equipment and
the disposal of Waste Electrical
and Electronic Equipment (WEEE).
The crossed wheelie bin symbol
indicates compliance and that the
products must be appropriately
recycled or processed in accordance
with these directives.
Important Safety Instructions
This symbol means that this unit
is double insulated. An earth
connection is not required.
You must allow a minimum 10 cm or 4 inches
of unobstructed clearance around the unit.
WARNING: The rear panel power cord connector
is the mains power disconnect device. The
device must be located in an open area that
allows access to the cord connector.
The unit must be connected to a power supply
only of the type and voltage specified on the
rear panel. (USA: 120 V/60Hz, EC: 230V/50Hz)
Connect the component to the power outlet
only with the supplied power supply cable or
an exact equivalent. Do not modify the supplied
cable. Do not use extension cords.
The mains plug is the disconnect of the unit. In
order to completely disconnect the unit from
the supply mains, remove the main plug from
the unit and the AC power outlet. This is the
only way to completely remove mains power
from the unit.
Use Class 2 wiring for speaker connections to
ensure proper installation and minimize the
risk of electrical shock.
The batteries in the remote control should not
be exposed to excessive temperature such as
sunshine, fire or other heat sources. Batteries
should be recycled or disposed as per state
and local guidelines.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following to
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference
that may cause undesired operation.
This product shall be connected to a MAINS
socket outlet with a protective earthing
connection.
The MAINS plug or an appliance coupler is used
as the disconnect device, the socket-outlet shall
be installed near the equipment and shall be
easily accessible.
3
Figure 1: Controls and Connections
Commandes et branchements
Bedienelemente und Anschlüsse
Controles y Conexiones
De bedieningsorganen en de aansluitingen
Controlli e collegamenti
Kontroller och anslutningar
Органы управления и разъемы
1: Power Button
Activate the unit or put it into standby mode.
2
: Power Indicator
3
: Headphone Output
Connect headphones for private listening.
4
: Remote Sensor
Receives IR commands from the remote
control.
567
Balance / Bass / Treble Buttons
Audio Control Buttons.
8
: Volume Knob
Adjust the volume output level.
9: Source Button
Selects the input signal source.
0: Auto Power Down
Enable or disable the Automatic Power Off
feature.
-: Service Port
Factory use only service connection.
=: 12V Trigger Output
Send a 12V trigger signal.
q: Ground Connector
Connect with a ground wire from the
turntable.
w: Phono Input
Connect to a turntable.
e: CD / Tuner / Aux Inputs
Analog “line level” inputs
r: Speaker Connectors
t: AC Power Inlet
2
1
3 4 5 8
6 7 9
=
w e r
-0
q t


Product specificaties

Merk: Rotel
Categorie: Receiver
Model: A10MKII

Heb je hulp nodig?

Als je hulp nodig hebt met Rotel A10MKII stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Rotel

Handleiding Receiver

Nieuwste handleidingen voor Receiver