STANDARD FEATURES
Some of the system’s standard features include:
4-button remote transmitter
LED Status indicator
Valet switch
Extended Range Receiver
125dB Multi-tone siren
Dual stage impact detector
Remote panic
Remote Valet mode
Remote chirp delete
Remote sensor bypass
Passive or active arming
Flashing parking lights
Auto Rearming
OPTIONAL FEATURES
This system has many optional features that
may require additional parts and/or labor.
Please contact your dealer for more details.
Remote keyless entry (door lock/unlock)
Illuminated entry
LCD 2-way Remote
Hood & trunk protection
Trunk/hatch release
Window roll-up
Additional sensors
Remote Start (optional plug-in module)
Stop & Go Feature
Auto Cold Start
Note: Some features may not be appropriate
for certain vehicles.
REMOTE TRANSMITTER BUTTONS
NOTE: Transmitter cosmetics may differ
between models and between standard 1-way
and LCD 2-way transmitters, but button
functions remain the same as described below.
Each transmitter button has two operating
modes: standard and level shifted. Pressing a
transmitter button for less than one second
activates the standard function associated with
that button (such as arm or disarm). Pressing a
button for more than one second changes the
color of the standard transmitter’s LED to
green and activates the level shift feature.
While the LED is green (level shifted), pressing
any transmitter button accesses another level
of commands providing expanded operation.
Transmitter Icons
Button 1 Button 2
Button 3 Button 4
SYSTEM MANUAL
VEHICLE SECURITY SYSTEM
Optional Remote Start Module and 2-way Transmitter Instructions Included
2
ARMING OPERATION
To arm the system press transmitter button 1:
The siren will chirp once.
The parking lights will flash once.*
The doors will lock.*
The LED will turn solid for 10 seconds
then start flashing slowly. After 10
seconds the system is armed.
During Arming, if an open hood or trunk is
detected, the system will wait 10 seconds for
the zone to close. If a door is open the system
will wait up to 60 seconds for the zone to close
(depending on door zone setting during
installation). If a zone remains open after the
wait period, the siren will chirp, the parking
lights will flash 4 times to indicate the zone is
still open. The system will then ignore that
zone, but keep all other areas protected.
While Armed, the system will trigger if:
The door, hood, or trunk is opened.
The shock sensor detects an impact.
An optional sensor is disturbed.
When triggered by the door or hood/trunk
input the siren will sound, the horn will honk,
and the parking lights will flash for 30 seconds.
If triggered by a sensor, the alarm cycle will last
15 seconds. If the alarm is triggered while the
optional remote start is engaged, the remote
start will immediately shut down.
If a zone triggers the system 3 times during a
single arming cycle, the system will bypass that
zone, keeping the other zones protected, until
the next time the system is armed.
If the shock sensor detects a light impact to the
vehicle or an optional sensor is disturbed, the
system will chirp and the parking lights will flash
5 times to warn away the potential intruder.
*Optional Feature
PASSIVE ARMING OPERATION
The passive arming feature allows the
system to arm automatically without user
intervention.This feature can be toggled on/off
using the transmitter.
To turn passive arming on/off:
1. Press and hold button 2 for level shift.
2. Press button 4.
The system will enter passive arming
operation mode.
The optional 2-way LCD transmitter
display will show “LAST DOOR ARM”.
To arm the system passively:
1. Turn the ignition key off.
2. Exit the vehicle and close all doors.
The siren will chirp and parking lights
will flash once after closing the last door.
The LED flashes rapidly indicating that
the system is preparing to arm. (The
system can be armed at any time by
pressing transmitter button 1.) NOTE:
Opening the hood/trunk or a door
resets the passive arming timer.
After 30 seconds the siren will chirp to
indicate the system is armed.
The doors will lock.†*
If Passive Locking was enabled during installation.
DISARMING OPERATION
To disarm the system press transmitter button 2.
The siren will chirp twice.¥
The parking lights will flash twice
The doors will unlock.*
The dome light will turn on.*
¥If the alarm was triggered while away, the system will respond
with 3 chirps and 4 parking light flashes.
*Optional Feature.
3
TAMPER ALERT
If the alarm was triggered while away from the
vehicle,the siren will chirp 3 times on disarming for
tamper indication. The triggered zone will be shown
on the optional 2-way LCD transmitter display.
AUTO REARM
If the system was armed for at least 10 seconds,
the Auto Rearm feature allows the system to
automatically re-arm itself 30 seconds after
disarming. The doors will also re-lock if
selected during installation. NOTE: Opening
the door resets the rearm timer, and opening
the trunk, hood, or turning on ignition cancels
the auto rearm feature.
AUTO IMMOBILIZER
The Auto Immobilizer feature automatically
engages the starter defeat relay 30 seconds
after turning off the ignition. This feature
provides an extra level of security even when
when the alarm is not set. When immobilized,
the vehicle will not start with the key until
either transmitter button 2 is pressed, or the
override button is pressed with the ignition on.
NOTE: The auto immobilizer feature does not
operate while in the valet mode.
To turn the immobilizer on/off:
1. Press and hold button 2 for level shift.
2. Press button 3.
The optional 2-way LCD transmitter
display will show “IMMOBILIZE”.
SILENT OPERATION MODE
Press transmitter button 4 to turn the arm and
disarm chirps on/off. NOTE: If the system is
disarmed, pressing button 4 to change the siren
status also arms the system. To disarm the
system, press button 2.
NOTE: The optional 2-way transmitter will still
beep to confirm systems arm/disarm.
IGNITION CONTROLLED LOCKS
The ignition controlled locks feature allows the
doors to automatically lock when the brake
pedal is pressed (after turning on the ignition
and closing all doors), and automatically unlock
when the ignition key is turned off. The ignition
controlled locking feature may also be
programmed for ignition lock without ignition
unlock, and off (no ignition control).
NOTE: If the optional remote start module is
not installed and ignition locking is desired, the
feature must be programmed for use without
brake. See Alarm Programmable Features.
REMOTE PANIC
In the event of an emergency (PANIC)
situation,the system’s siren can be triggered for
30 seconds to attract attention.
To activate the Panic Feature:
Press transmitter buttons I&2 for 3 seconds.
The siren will sound.
The parking lights will flash.
The starter defeat will activate.
Press button I to exit panic mode and rearm
the system. Press button 2 to exit panic mode
and disarm the system. The Panic Feature will
NOT operate when the ignition is on.
EMERGENCY OVERRIDE
If the transmitter becomes lost or fails to
operate, the system can be disarmed by using
the emergency override feature.
To override the system:
1. Enter the vehicle.
Because the system is armed, the siren
will sound.
2. Turn on the ignition key.
3. Press the Valet switch for 3 seconds.
The siren will stop sounding.
Starter defeat bypassed.


Product specificaties

Merk: Pyle
Categorie: Alarmsysteem
Model: PWD501
Soort bediening: Knoppen
Kleur van het product: Zwart
Gebruikershandleiding: Ja
Smartphone ondersteuning op afstand: Nee
Ingangsspanning: 12 V
Aantal gelijktijdig verbonden apparaten (max): 2
Wifi: Nee
Type beeldscherm: LCD
Aantal bewegingssensoren: - stuk(s)
Alarm decibels: 125 dB
Aantal afstandsbedieningen: 2 stuk(s)
Aantal deur-/raamsensoren: - stuk(s)
Aantal ondersteunde afstandsbedieningen: 2

Heb je hulp nodig?

Als je hulp nodig hebt met Pyle PWD501 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Alarmsysteem Pyle

Pyle

Pyle PWD501 Handleiding

11 April 2023
Pyle

Pyle PWD206 Handleiding

10 Maart 2023
Pyle

Pyle PWD901 Handleiding

30 Januari 2023
Pyle

Pyle PWD603RS Handleiding

16 Januari 2023
Pyle

Pyle PWD701 Handleiding

1 November 2022

Handleiding Alarmsysteem

Nieuwste handleidingen voor Alarmsysteem