Premier Mounts PRC-LA Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Premier Mounts PRC-LA (11 pagina's) in de categorie Flat panel steun. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/11
INSTALLATION INSTRUCTIONS
NORTH AMERICA
3130 East Miraloma Avenue
Anaheim, CA 92806 USA
USA and Canada
Phone: 1.800.368.9700
Fax: 1.800.832.4888
Other Locations
Phone: (001).714.632.7100
Fax: (001).714.632.1044
EUROPE
Swallow House,
Shilton Industrial Estate,
Shilton, Coventry, England CV79JY
Phone: +44 (0) 2476 614700
Fax: +44 (0) 2476 614710
PRC-LA
Ceiling Lower Assembly Flat Panel Mount
9533-004-011-01
PRC-LA
Page 2 Visit the Premier Mounts website at http://www.mounts.com Installation Instructions
Contact Premier Mounts with any questions:
(800) 368-9700
techsupport@mounts.com
Contents
Warning Statements
Weight Limit
Maximum Flat Panel Weight: 50 lbs.
THE CEILING STRUCTURE MUST BE CAPABLE OF
SUPPORTING AT LEAST FIVE TIMES THE WEIGHT OF
THE FLAT PANEL. IF NOT, THE CEILING STRUCTURE
MUST BE REINFORCED.
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND
COMPLETELY UNDERSTOOD. KEEP THESE INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION
FOR FUTURE REFERENCE.
PROPER INSTALLATION PROCEDURE BY A QUALIFIED SERVICE TECHNICIAN MUST BE FOLLOWED, AS OUTLINED
IN THESE INSTALLATION INSTRUCTIONS. FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS
PERSONAL INJURY, OR EVEN DEATH.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE
PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY
UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS,
DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR
IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
At least two qualiî‚¿ed people should perform the assembly procedure. Personal injury and/or property damage can result
from dropping or mishandling the projector.
If mounting to wall studs or ceiling studs, make sure that the mounting screws are anchored into the center of the wall studs
or ceiling studs. Use of an edge-to-edge stud î‚¿nder is recommended.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there
are no electrical wires in wall. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the wall where the mount is to be located. Cutting or drilling into a
water or gas line may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious
personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of
impact.
Weight Limit. .................................................................................................................................................................... 2
Warning Statements. ....................................................................................................................................................... 2
Installation Tools. ............................................................................................................................................................. 3
Parts List.......................................................................................................................................................................... 3
Mounting Hardware. ........................................................................................................................................................ 4
Features. ......................................................................................................................................................................... 5
Installing the PRC-LA Mount. .......................................................................................................................................... 6
Introduction. .............................................................................................................................................................. 6
Attaching the PRC-LA. .................................................................................................................................................... 6
Mounting Hardware. ........................................................................................................................................................ 7
Selecting the Mounting Hardware. ............................................................................................................................ 7
Universal Spacer Installation. ................................................................................................................................... 8
UFP-280 Adapter Plate Installation. .......................................................................................................................... 8
Attaching the Flat Panel to the PRC-LA Mount. .............................................................................................................. 9
Adjusting the Mount Tension. ........................................................................................................................................ 10
Technical Speciî‚¿cations. ............................................................................................................................................... 10
Warranty. ........................................................................................................................................................................11
Disclaimer. ......................................................................................................................................................................11
PRC-LA
Installation Instructions Visit the Premier Mounts website at http://www.mounts.com Page 3
Parts List
Installation Tools
Make sure your Premier Mounts product has the following hardware and components before beginning installation. If
there are parts missing and/or damaged, stop the installation and call Premier Mounts at (800) 368-9700.
PRC-LA Mount Hardware
PRC-LA
(Qty 1)
The following tools may be required depending upon your particular installation. They are not included.
Pencil Protective Eyewear Phillips Tip Screwdriver
Power Drill
Ladder
Tape Measure
Socket Wrench
UFP-280 Adapter Plate
(Qty 1)
M3 Allen Wrench
(Supplied)
Universal Spacers
(Qty 30) M4 Flat Washers
(Qty 4)
Thread Depth Indicator
(Supplied)
M5 Flat Washers
(Qty 4)
14mm Socket
(Supplied)


Product specificaties

Merk: Premier Mounts
Categorie: Flat panel steun
Model: PRC-LA
Kleur van het product: Zwart
Gewicht: 2700 g
Montagewijze: Plafond
Maximale gewichtscapaciteit: 22.7 kg
Paneelmontage-interface: 75 x 75,100 x 100,200 x 100,200 x 200 mm
Verstelbaar: Ja
Compatibele producten: 1.5 NPT
Draaihoek: 360 °
Montage interface compatibiliteit (min): 75 x 75 mm
Montage interface compatibiliteit (max): 200 x 200 mm
Aantal displays ondersteund: 1
Bereik kantelhoek: -15 - 15 °

Heb je hulp nodig?

Als je hulp nodig hebt met Premier Mounts PRC-LA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Flat panel steun Premier Mounts

Handleiding Flat panel steun

Nieuwste handleidingen voor Flat panel steun