INSTALLATION INSTRUCTIONS
CREATING POSITIVE CUSTOMER EXPERIENCES
9531-041-001-01
ECM-D70T / ECM-D70T1.5
Elliptical Ceiling Dual Mount for 37˝ to 50˝ Flat Panels
ECM-D70T / ECM-D70T1.5
Page 2 Visit the Premier Mounts website at http://www.premiermounts.com Installation Instructions
Contact Premier Mounts with any questions:
(800) 368-9700
techsupport@mounts.com
Contents
Warning Statements
PRIOR TO THE INSTALLATION OF THIS PRODUCT, THE INSTALLATION INSTRUCTIONS MUST BE READ AND
COMPLETELY UNDERSTOOD TO PREVENT PERSONAL INJURY AND PROPERTY DAMAGE. KEEP THESE
INSTALLATION INSTRUCTIONS IN AN EASILY ACCESSIBLE LOCATION FOR FUTURE REFERENCE.
PREMIER MOUNTS DOES NOT WARRANT AGAINST DAMAGE CAUSED BY THE USE OF ANY PREMIER MOUNTS
PRODUCT FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED OR DAMAGE CAUSED BY
UNAUTHORIZED ATTACHMENTS OR MODIFICATIONS, AND IS NOT RESPONSIBLE FOR ANY DAMAGES, CLAIMS,
DEMANDS, SUITS, ACTIONS OR CAUSES OF ACTION OF WHATEVER KIND RESULTING FROM, ARISING OUT OF OR
IN ANY MANNER RELATING TO ANY SUCH USE, ATTACHMENTS OR MODIFICATIONS.
SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE
PROPER SAFETY GEAR AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
At least two qualied people should perform the assembly procedure. Personal injury and/or property damage can result
from dropping or mishandling the at-panel.
Be aware of the mounting environment. If drilling and/or cutting into the mounting surface, always make sure that there are
no electrical wires in the ceiling. Cutting or drilling into an electrical line may cause serious personal injury.
Make sure there are no water or natural gas lines inside the ceiling where the mount is to be located. Cutting or drilling into a
water or gas line may cause severe property damage or personal injury.
This product is intended for indoor use only. Use of this product outdoors could lead to product failure and/or serious
personal injury.
Do not install near sources of high heat. Do not install on a structure that is prone to vibration, movement or chance of
impact.
Weight Capacity
Maximum at-panel weight: 180lbs. THE CEILING STRUCTURE MUST BE CAPABLE OF HOLDING
FIVE (5) TIMES THE WEIGHT OF THE FLAT PANEL AND
MOUNT. IF NOT, THEN THE CEILING STRUCTURE MUST BE
REINFORCED.
INSTALL THE MOUNT ACCORDING TO THE INSTRUCTIONS PROVIDED BY PREMIER MOUNTS. PERFORM ALL
STRUCTURAL REINFORCEMENTS BEFORE ATTACHING THE FLAT PANEL TO THE CEILING MOUNT. USE THE
APPROPRIATE LIFTING DEVICE WHEN LIFTING THE FLAT PANEL INTO PLACE.
Installation Tools. ...................................................................................................................................................... 3
Parts List................................................................................................................................................................... 3
Mounting Hardware. ................................................................................................................................................. 4
Features. 5 ..................................................................................................................................................................
Selecting the Appropriate Mounting Hardware. ........................................................................................... 7
Griplate™ Washer Installation. 8 ....................................................................................................................
Nylon Spacer Installation. 8 ............................................................................................................................
Flat-Panel Installation. 9 ..............................................................................................................................................
Cable Management. 10 ...............................................................................................................................................
Tilt Positioning. ....................................................................................................................................................... 11
Optional Mounting Congurations and Accessories. .............................................................................................. 11
Technical Specications. ........................................................................................................................................ 12
Warranty 13 .................................................................................................................................................................
Disclaimer. 13 ..............................................................................................................................................................
ECM-D70T / ECM-D70T1.5
Installation Instructions Visit the Premier Mounts website at http://www.premiermounts.com Page 3
Parts List
Installation Tools
The following tools may be required depending upon your particular installation.
Make sure that none of these parts are missing and/or damaged before beginning installation. If there are, stop the
installation and call Premier Mounts at (800) 368-9700.
Elliptical Tlit Mount (Qty 1)
ECM-D70T Mount Hardware
Mounting Bracket Arms (Qty 4)
Pencil
Phillips Tip
Screwdriver
Tape Measure
Ladder
Protective Eye Wear
Decorative Covers (Qty 4)
Thread Depth Indicator (Qty 2)
M6 x 25mm Phillips Screws (Qty 4)
M4 x 8mm Phillips Screws (Qty 4)


Product specificaties

Merk: Premier Mounts
Categorie: Flat panel steun
Model: ECM-D70T
Kleur van het product: Zwart
Gewicht: 24600 g
Breedte: 945 mm
Hoogte: 549 mm
Montagewijze: Plafond
Maximale gewichtscapaciteit: 79.5 kg
Draaihoek: 360 °
Montage interface compatibiliteit (min): 200 x 200 mm
Montage interface compatibiliteit (max): 875 x 505 mm
Aantal displays ondersteund: 2
Bereik kantelhoek: -15 - 15 °
Maximale schermgrootte: 46 "
Minimale schermgrootte: 40 "