Planet POE-400 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Planet POE-400 (4 pagina's) in de categorie Netwerkkaart/adapter. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
- 1 -
- 2 -
- 3 -
- 4 -
- 5 -
- 6 -
- 7 -
- 8 -
1. Introduction
1.1 Checklist
Thank you for purchasing our POE-400 IEEE 802.3af Power
over Ethernet Injector Hub, your Power over Ethernet
Injector Hub package shall contains following contents:
Check the contents of your package for following
parts:
l Power over Ethernet Injector Hub x 1
l User’s Manual CD x 1
l Power Adapter x 1
l Power Cord x 1
If any of these pieces are missing or damaged, please
contact your dealer immediately, if possible, retain the
carton including the original packing material, and use them
against to repack the product in case there is a need to
return it to us for repair.
1.3 Features
u Complies with IEEE 802.3, IEEE 802.3u, 10/100Base-TX
u Complies with IEEE 802.3af, 48V DC power over unused
twisted-pair wires
u 4-Port IEEE 802.3af in-line mid-span power injector box
u Full power support for per POE port
u Circuit protection prevent power interference between
ports
u LED indicator power input indication
u Desktop palm size
2.2 POE-400 and POE-152S, the IEEE
802.3af Injector / Splitter and Equipment
Installation
For the places hard to î‚¿nd the power inlet, the POE-400
provide the easiest way to power your Ethernet devices
such as PLANET IEEE 802.3af Power over Ethernet Splitter
(POE-152S) with Internet Camera (ICA-M220) or Wireless
Access Point (WNAP-3000PE) installed in the small ofî‚¿ce.
To control the power system of your networking devices, the
POE-400 can directly co-work with PLANET ICA-HM230 and
POE IP Phone VIP-351PT to build VoIP telephony network in
the ofî‚¿ce. Besides, the POE-400 can be directly deployed to
connect the third party IEEE 802.3af devices like Cisco AP
and POE switches installed 100 meters away.
1.5 Product Outlook
LED Deî‚¿nition:
LED Color Function
Power Green Lights to indicate that the POE-400
has power.
PoE Ready /
In-Use Green Lights to indicate the port is
providing 48VDC in-line power.
1.2 About the Power over Ethernet Injector
Hub
The PLANET POE-400 is a 4-Port IEEE 802.3af Power over
Ethernet injector hub complied with IEEE 802.3, IEEE
802.3u and IEEE 802.3af standards. Equipped with 4
10/100Base-TX Fast Ethernet ports, the POE-400 supports
full 48V DC power for any remote IEEE 802.3af powered
device (PD) like Wireless LAN Access Point, IP Phone, and
LAN Camera. Supporting power supply of 70 Watts, POE-
400 provides sufî‚¿cient power to the 4 remote devices.
There are 8 RJ-45 STP ports on POE-400. Half of the ports
on right panel function as "Data" and the other half on left
panel function as "Data and Power". Each of the "Data
and Power" port as an injector which inserts DC Voltage
into the CAT 5 cable allowing the cable between the Injector
and Splitter to transfer data and power simultaneously.
1.4 Speciî‚¿cation
Model POE-400
Ethernet Connector
8-Port RJ-45 STP with 4-Port
"Data" and 4-Port "Data and
Power"
Ethernet Data Rate 10/100Mbps (vary on Ethernet
device attached)
Input Voltage DC 48V, 1.5A
Number of Device
can be Power 4
Ethernet Cable TIA/EIA-568, Category 5/5e cable
LED Indicator 1 x power, 4 x POE ready / in-use
Operating
Environment 0~50 Degree C, 5%~90%RH
Storage Environment -10~70 Degree C, 5%~90%RH
Dimension
(H x W x D) 26 x 70 x 97mm
Weight 220g
Emission FCC Class B, CE mark
Standard Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3af Power over Ethernet
2. Hardware Installation
This product provides two different running speeds –
10Mbps, 100Mbps, in the same device and automatically
distinguishes the speed of incoming connection.
This section describes the hardware features of POE-400.
Before connecting any network device to the POE-400, read
this chapter carefully.
2.1. Before Installation
Before your installation, it is recommended to check your
network environment. If there is any IEEE 802.3af devices
need to power on, the POE-400 can provide you a way
to supply power for this Ethernet device conveniently and
easily. The POE-400 equips with an AC-DC adapter with
DC 48V input and injects this DC power into the pin of the
twisted pair cable (pair 4, 5 and pair 7, 8).
If there is very difî‚¿cult to î‚¿nd a power socket for AC-DC
Adapter of your non-IEEE 802.3af networked device, the
POE-400 and POE-152S can provide you a way to supply
DC power for this Ethernet device conveniently and easily.
The 10Mbps or 100Mbps speed, duplex mode from Data
port of POE-400 depends on which Ethernet device
attached.
Notebook
PCPCPCPC
Internet Camera
Internet Camera
POE-Splitter
Switch
POE-400
POE-AP
VoIP Phone
PoE
PoE
PoE
PoE
DC
DC Power Line (DC)
100Base-TX UTP
PoE
100Base-TX UTP with PoE
Figure 1: Connection architecture over POE-400
Note
1. According to IEEE 802.3af standard, the
POE-400 will not inject power to the cable
if not connecting to IEEE 802.3af devices.
2. Due to the capability of IEEE 802.3af
standard, the POE-400 can directly connect
with any IEEE 802.3af end-nodes.
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
3. Troubleshooting
This chapter contains information to help you solve
problems. If the PoE Injector Hub is not functioning
properly, make sure the PoE Injector Hub was set up
according to instructions in this manual.
How to let my non IEEE 802.3af network devices
can work with POE-400?
Solution:
You can use PLANET Power over Ethernet Splitter, such as
PLANET POE-152S to work as a power transformer between
POE-400 and non IEEE 802.3af devices. Two types of POE-
152S are available for different voltage, 5V DC and 12V DC.
The PoE LED is not lit
Solution:
Check the cable connection between POE-400 and IEEE
802.3af device.
Appendix A Networking Connection
Switch's RJ-45 Pin Assignments
10/100Mbps, 10/100Base-TX
RJ-45 Connector pin assignment
Contact
MDI
Media Dependant
Interface
MDI-X
Media Dependant
Interface -Cross
1 Tx + (transmit) Rx + (receive)
2 Tx - (transmit) Rx - (receive)
3 Rx + (receive) Tx + (transmit)
4, 5 IEEE 802.3af DC 48V
6 Rx - (receive) Tx - (transmit)
7, 8 IEEE 802.3af DC 0V
Why I connect my PoE device to POE-400 and it
cannot power on?
Solution:
1. Please check the cable type of the connection from POE-
400 to the other end. The cable should be an 8-wire UTP,
Category 5/5e, EIA568 cable within 100 meters. A cable
with only 4-wire, short loop or over 100 meters, all will
affect the power supply.
2. Please check and assure the device that fully complied
with IEEE 802.3af standard.
The standard RJ-45 receptacle/connector
There are 8 wires on a standard UTP/STP cable and each
wire is color-coded. The following shows the pin allocation
and color of straight cable and crossover cable connection:
Straight Cable
Cross Over Cable
SIDE 1
SIDE 1
SIDE 2
SIDE 1
SIDE 2
12345678
12345678
12345678
12345678
SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
SIDE 1 SIDE 2
1 = White/Orange
2 = Orange
3 = White/Green
4 = Blue
5 = White/Blue
6 = Green
7 = White/Brown
8 = Brown
1 = White/Green
2 = Green
3 = White/Orange
4 = Blue
5 = White/Blue
6 = Orange
7 = White/Brown
8 = Brown
Figure A-1: Straight-Through and Crossover Cable
Please make sure your connected cables are with same pin
assignment and color as above picture before deploying the
cables into your network.
Energy Saving Note of the Device
This power required device does not support Standby mode
operation.
For energy saving, please remove the power cable to
disconnect the device from the power circuit.
Without removing power cable, the device will still
consuming power from the power source. In the view of
Saving the Energy and reduce the unnecessary power
consuming, it is strongly suggested to remove the power
connection for the device if this device is not intended to be
active.


Product specificaties

Merk: Planet
Categorie: Netwerkkaart/adapter
Model: POE-400
Gewicht: 220 g
LED-indicatoren: Ja
Stroom: 1.5 A
Certificering: FCC Class B, CE
Voldoet aan industriestandaarden: IEEE 802.3, IEEE 802.3u, IEEE 802.3af
Ethernet LAN, data-overdrachtsnelheden: 10, 100 Mbit/s
Temperatuur bij opslag: -20 - 70 °C
Luchtvochtigheid bij opslag: 5 - 90 procent
Ethernet interface type: Fast Ethernet
Power over Ethernet (PoE): Ja
Afmetingen (B x D x H): 70 x 97 x 26 mm
Bedrijfstemperatuur (T-T): 0 - 50 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 90 procent
Stroom via Ethernet (PoE): 48 V

Heb je hulp nodig?

Als je hulp nodig hebt met Planet POE-400 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden