Perlick PKD24A Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Perlick PKD24A (19 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/19
perlick.com
PKD24A
INSTALLATION & OPERATION
Rev. 11.07.22
Owner’s Manual
Keep with machine for reference
T C ABLE OF ONTENTS
P PKD24A ERLICK
1. SPECIFICATIONS ..................................................................................................... 2
1.1. PKD24A .............................................................................................. E ! B .RROR OOKMARK NOT DEFINED
1.2. PKD24A PERATIONAL O CYCLE .............................................................................................................. 3
2. GETTING STARTED ................................................................................................. 5
2.1. PKD24A INTRODUCTION TO THE ............................................................................................................ 5
2.2. R I 6ECEIVING AND NSTALLATION ...............................................................................................................
2.2.1. Electrical . 6................................................................................................................................
2.2.2. Plumbing ................................................................................................................................. 6
2.2.3. Post Instructions ..................................................................................................................... 6
2.2.4. Installers Checklist .................................................................................................................. 7
3. ........................................................................................................... OPERATION 8
3.1. I S NITIAL ETUP ..................................................................................................................................... 8
3.1.1. Check… .................................................................................................................................... 8
3.1.2. Chemicals ................................................................................................................................ 8
3.1.3. Filling the Machine ................................................................................................................. 8
3.2. G 8ENERAL ...........................................................................................................................................
3.2.1. Pre- Scrapping.......................................................................................................................... 8
3.2.2. Proper Chemical Dosage ......................................................................................................... 8
3.2.3. Proper Filling ........................................................................................................................... 9
3.2.4. Water Pump ............................................................................................................................ 9
3.2.5. Pump Cavitation 9.....................................................................................................................
4. MAINTENANCE .................................................................................................... 10
4.1. T IMER ASSEMBLY ............................................................................................................................... 10
4.1.1. Cam Adjustment ................................................................................................................... 10
4.2. Q UICK SERVICE GUIDE......................................................................................................................... 11
4.3. 12 T ROUBLESHOOTING ...........................................................................................................................
5. ADDENDUM FOR MACHINES INSTALLED IN THE CITY OF CHICAGO ...................... 15
APPENDIX A: OPERATOR & CLEANING INSTRUCTIONS ................................................ 16
6. ELECTRICAL DIAGRAM .........................................................................................17
PKD24A INSTALLATION & OPERATION MANUAL Rev. 11.07.22 Page
2
1. Specifications
1.1. PDK24A
WATER CONSUMPTION
PER RACK
1.7 GAL.
6.44 L
PER HOUR 40.8 GAL. 154.4 L
OPERATING CYCLE
WASH TIME-SEC
57
57
RINSE TIME-SEC
48
48
DWELL TIME-SEC 15 15
TOTAL CYCLE
2 MIN.
2 MIN.
OPERATING CAPACITY
RACKS PER HOUR
30
30
WASH TANK CAPACITY
1.7 GAL.
6.44 L
PUMP CAPACITY 35 GPM 132.5 LPM
WATER REQUIREMENTS
140°F
60°C
WATER INLET
½”
1.27 cm
DRAIN CONNECTION
1”
2.54 cm
CYCLE
TEMPERATURES(recommended)
140°F 60°C
WASH- °F (Min) 120°F 52°C
FRAME DIMENSIONS
DEPTH
24 3/4”
63 cm
WIDTH 24” 61 cm
HEIGHT (34 ¾”), with legs adjusted 39 99 -40 1/8 -102 cm
MAX CLEARANCE FOR GLASSES
11 ¼”
28.57cm
ELECTRICAL*
115 VAC
16 AMPS
SUSTAINER HEATER
( Not Booster Heater)
1.25 kW
WASH PUMP MOTOR
13.4 AMPS
*MUST CONNECT TO DEDICATED 20 AMP SUPPLY CIRCUIT.
COMPLIANCE WITH LOCAL ELECTRICAL CODES MUST BE FOLLOWED.
PKD24A (Approximate) 244# 110.6 kg
WARNING: alifornia Prop 5 Notic C 6 e
These roducts may xpose ou to hemicals ncluding hromium, hich e nown o he tate of alifornia to p e y c i C w ar k t t s C
cause ancer d irth efects r ther eproductive arm. For re nformation n hether a product n his ist c an b d o o r h mo i o w i t l
contain th chemicals, lea refer o he ecific roducts ese p se t t sp p page erlick.com. Or o ind ut re out at p t f o mo ab Prop 65,
go o t P65Warnings.ca.gov.
METRIC
EQUIVALENT


Product specificaties